메뉴 건너뛰기




Volumn 24, Issue 12, 1997, Pages 1935-1942

Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetry

Author keywords

Absorption spectra; Densitometer; GAFChromic film; Optical density; Radiochromic film

Indexed keywords

ABSORPTION SPECTRA; ABSORPTION SPECTROSCOPY; BANDPASS FILTERS; CURVE FITTING; DENSITOMETERS; DENSITY (OPTICAL); DENSITY MEASUREMENT (OPTICAL); DOSIMETRY; ELECTROMAGNETIC WAVE ABSORPTION; LIGHT EMITTING DIODES; LIGHT TRANSMISSION; METEOROLOGICAL INSTRUMENTS; PREDICTIVE ANALYTICS;

EID: 0031455608     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598107     Document Type: Article
Times cited : (57)

References (15)
  • 2
    • 0000331924 scopus 로고
    • The response of plastic dosimeters to gamma rays and electrons at high absorbed dose rates
    • W. L. McLaughlin, J. C. Humphreys, B. B. Radak, A. Miller, and T. A. Olejnik, "The response of plastic dosimeters to gamma rays and electrons at high absorbed dose rates," Radiat. Phys. Chem. 14, 535-550 (1979)
    • (1979) Radiat. Phys. Chem. , vol.14 , pp. 535-550
    • McLaughlin, W.L.1    Humphreys, J.C.2    Radak, B.B.3    Miller, A.4    Olejnik, T.A.5
  • 3
    • 0002875604 scopus 로고
    • The measurement of absorbed dose and dose gradients
    • W. L. McLaughlin, "The measurement of absorbed dose and dose gradients," Radiat. Phys. Chem. 15, 9-38 (1980).
    • (1980) Radiat. Phys. Chem. , vol.15 , pp. 9-38
    • McLaughlin, W.L.1
  • 5
    • 0011681527 scopus 로고
    • Radiochromic film densitometry for high dose-rate Ir-192 dosimetry: Accuracy and precision
    • V. Mishra, J. F. Williamson, Z. Li, and A. S. Meigooni, "Radiochromic film densitometry for high dose-rate Ir-192 dosimetry: Accuracy and precision," Med. Phys. 20, 865 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 865
    • Mishra, V.1    Williamson, J.F.2    Li, Z.3    Meigooni, A.S.4
  • 6
    • 0011631309 scopus 로고
    • Tissue interface dosimetry with GAFChromic film
    • A. S. Meigooni, E E. Klein, C. Durbin, and J. A. Purdy, "Tissue interface dosimetry with GAFChromic film." Med Phys. 20, 1298 (1993).
    • (1993) Med Phys. , vol.20 , pp. 1298
    • Meigooni, A.S.1    Klein, E.E.2    Durbin, C.3    Purdy, J.A.4
  • 7
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • W. L. McLaughlin, C. G. Soares, J. A. Sayeg, E. C. McCullough, R. W. Kline, A. Wu, and A. H. Maitz. "The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics." Med. Phys. 21, 379-388 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maitz, A.H.7
  • 8
    • 0028349847 scopus 로고
    • The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery
    • R. Ramani, A. W. Lightstone, D. L. D. Mason, and P. F. O'Brien, "The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery," Med. Phys. 21, 389-392 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 389-392
    • Ramani, R.1    Lightstone, A.W.2    Mason, D.L.D.3    O'Brien, P.F.4
  • 11
    • 0029832035 scopus 로고    scopus 로고
    • Dosimetric characteristics of an improved radiochromic film
    • A. S. Meigooni, M. I. Sanders, G. S Ibbott, and S. R. Szeglin, "Dosimetric characteristics of an improved radiochromic film," Med Phys. 23, 1883-1888 (1996).
    • (1996) Med Phys. , vol.23 , pp. 1883-1888
    • Meigooni, A.S.1    Sanders, M.I.2    Ibbott, G.S.3    Szeglin, S.R.4
  • 12
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    • Y. Zhu, A. S. Kirov, V Mishra, A. S. Meigooni, and J. F. Williamson, "Quantitative evaluation of radiochromic film response for two-dimensional dosimetry," Med. Phys 24, 223-231 (1997).
    • (1997) Med. Phys , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3    Meigooni, A.S.4    Williamson, J.F.5
  • 13
    • 0025895699 scopus 로고
    • Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide and LiF TLD's used for brachytherapy dosimetry
    • P. J. Muench, A. S. Meigooni, R. Nath, and W. L. McLaughlin, "Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide and LiF TLD's used for brachytherapy dosimetry," Med. Phys. 18, 769-775 (1991)
    • (1991) Med. Phys. , vol.18 , pp. 769-775
    • Muench, P.J.1    Meigooni, A.S.2    Nath, R.3    McLaughlin, W.L.4
  • 14
    • 0025238416 scopus 로고
    • GAFChromic dosimetry media: A new high dose thin film routine dosimeter and dose mapping tool
    • R. D. H. Chu, G. Van Dyk, D. F. Lewis, K. P. J. O'Hara, B. W. Buckland, and F. Dinelle, "GAFChromic dosimetry media: A new high dose thin film routine dosimeter and dose mapping tool," Radiat. Phys. Chem. 35, 767-773 (1990).
    • (1990) Radiat. Phys. Chem. , vol.35 , pp. 767-773
    • Chu, R.D.H.1    Van Dyk, G.2    Lewis, D.F.3    O'Hara, K.P.J.4    Buckland, B.W.5    Dinelle, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.