메뉴 건너뛰기




Volumn 32, Issue 6, 1997, Pages 382-388

ROC analysis of Heidelberg Retina Tomograph optic disc shape measures in glaucoma

Author keywords

Corrected pattern standard deviation; Heidelberg Retina Tomograph; Mean defect; ROC curve; Sensitivity; Specificity; Visual field indices

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; GLAUCOMA; HUMAN; MAJOR CLINICAL STUDY; MORPHOMETRICS; OPTIC DISK; OPTIC DISK CUP; RANDOMIZED CONTROLLED TRIAL; RECEIVER OPERATING CHARACTERISTIC; RETINA NEUROEPITHELIAL LAYER; TOMOGRAPHY; VISUAL FIELD;

EID: 0031454728     PISSN: 00084182     EISSN: 17153360     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (72)

References (23)
  • 1
    • 84899780831 scopus 로고
    • Chronic human glaucoma causing selectively greater loss of large optic nerve fibers
    • Quigley HA, Dunkelberger GR, Green WR. Chronic human glaucoma causing selectively greater loss of large optic nerve fibers. Ophthalmology 1989;96:26-32.
    • (1989) Ophthalmology , vol.96 , pp. 26-32
    • Quigley, H.A.1    Dunkelberger, G.R.2    Green, W.R.3
  • 2
    • 0028033023 scopus 로고
    • Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma
    • Abrams LS, Scott IU, Speath GL, Quigley HA, Varma R. Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma. Ophthalmology 1994;101:1662-7.
    • (1994) Ophthalmology , vol.101 , pp. 1662-1667
    • Abrams, L.S.1    Scott, I.U.2    Speath, G.L.3    Quigley, H.A.4    Varma, R.5
  • 5
    • 0023739150 scopus 로고
    • Optic disc morphometry in chronic primary open-angle: 2. Correlation of the intrapapillary morphometric data to visual field indices
    • Jonas JB, Gusek GC, Naumann GOH. Optic disc morphometry in chronic primary open-angle: 2. Correlation of the intrapapillary morphometric data to visual field indices. Graefes Arch Clin Exp Ophthalmol 1988;226: 531-8.
    • (1988) Graefes Arch Clin Exp Ophthalmol , vol.226 , pp. 531-538
    • Jonas, J.B.1    Gusek, G.C.2    Naumann, G.O.H.3
  • 6
    • 0023927383 scopus 로고
    • Correlation of structure and function in glaucoma: Quantitative measurements of disc and field
    • Caprioli J, Miller JM. Correlation of structure and function in glaucoma: quantitative measurements of disc and field. Ophthalmology 1988;95:723-7.
    • (1988) Ophthalmology , vol.95 , pp. 723-727
    • Caprioli, J.1    Miller, J.M.2
  • 7
    • 1842356916 scopus 로고
    • Correlation between optic disc changes and visual field loss in patients with unilateral glaucoma
    • Mills RP, editor. Amsterdam: Kugler Publications
    • Funk J, Soriano JM, Ebner D. Correlation between optic disc changes and visual field loss in patients with unilateral glaucoma. In Mills RP, editor. Perimetry update 1992-93. Amsterdam: Kugler Publications, 1993:159-63.
    • (1993) Perimetry Update 1992-93 , pp. 159-163
    • Funk, J.1    Soriano, J.M.2    Ebner, D.3
  • 8
    • 0027198822 scopus 로고
    • Effect of repetitive imaging on topographic measurements of the optic nerve head
    • Weinreb RN, Lusky M, Bartsch DU, Morsman D. Effect of repetitive imaging on topographic measurements of the optic nerve head. Arch Ophthalmol 1993;111:636-8.
    • (1993) Arch Ophthalmol , vol.111 , pp. 636-638
    • Weinreb, R.N.1    Lusky, M.2    Bartsch, D.U.3    Morsman, D.4
  • 9
    • 0027312137 scopus 로고
    • Reproducibility of topographic parameters obtained with the Heidelberg Retina Tomograph
    • Mikelberg FS, Wijsman K, Schulzer M. Reproducibility of topographic parameters obtained with the Heidelberg Retina Tomograph. J Glaucoma 1993;2:101-3.
    • (1993) J Glaucoma , vol.2 , pp. 101-103
    • Mikelberg, F.S.1    Wijsman, K.2    Schulzer, M.3
  • 10
    • 0027162051 scopus 로고
    • Reproducibility of topometric data acquisition in normal and glaucomatous optic nerve heads with the laser tomographic scanner
    • Rohrschneider K, Burk ROW, Volcker H. Reproducibility of topometric data acquisition in normal and glaucomatous optic nerve heads with the laser tomographic scanner. Graefes Arch Clin Exp Ophthalmol 1993;231:457-64.
    • (1993) Graefes Arch Clin Exp Ophthalmol , vol.231 , pp. 457-464
    • Rohrschneider, K.1    Burk, R.O.W.2    Volcker, H.3
  • 11
    • 0024444629 scopus 로고
    • Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning
    • Kruse FE, Burk RO, Volcker HE, Zinser G, Harbath V. Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning. Ophthalmology 1989;96:1320-4.
    • (1989) Ophthalmology , vol.96 , pp. 1320-1324
    • Kruse, F.E.1    Burk, R.O.2    Volcker, H.E.3    Zinser, G.4    Harbath, V.5
  • 12
    • 0026058265 scopus 로고
    • Reproducibility of topographic measurements of normal and glaucomatous optic nerve head with the laser tomographic scanner
    • Dreher AW, Tso PC, Weinreb RN. Reproducibility of topographic measurements of normal and glaucomatous optic nerve head with the laser tomographic scanner. Am J Ophthalmol 1991;111:221-9.
    • (1991) Am J Ophthalmol , vol.111 , pp. 221-229
    • Dreher, A.W.1    Tso, P.C.2    Weinreb, R.N.3
  • 13
    • 0027404260 scopus 로고
    • Confocal laser scanning ophthalmoscope: Reproducibility of optic nerve head topographic measurements with the confocal scanning laser ophthalmoscope
    • Cioffi GA, Robin AL, Eastman RD, Perell HF, Sarfarazi FA, Kelman SE. Confocal laser scanning ophthalmoscope: reproducibility of optic nerve head topographic measurements with the confocal scanning laser ophthalmoscope. Ophthalmology 1993;100:57-62.
    • (1993) Ophthalmology , vol.100 , pp. 57-62
    • Cioffi, G.A.1    Robin, A.L.2    Eastman, R.D.3    Perell, H.F.4    Sarfarazi, F.A.5    Kelman, S.E.6
  • 14
    • 0027294851 scopus 로고
    • Reproducibility of optic nerve head topography measurements in eyes with undilated pupils
    • Lusky M, Bosem ME, Weinreb RN. Reproducibility of optic nerve head topography measurements in eyes with undilated pupils. J Glaucoma 1993;2:104-9.
    • (1993) J Glaucoma , vol.2 , pp. 104-109
    • Lusky, M.1    Bosem, M.E.2    Weinreb, R.N.3
  • 15
    • 0025236882 scopus 로고
    • The contour of the juxtapapillary nerve fiber layer in glaucoma
    • Caprioli J. The contour of the juxtapapillary nerve fiber layer in glaucoma. Ophthalmology 1990;97:358-66.
    • (1990) Ophthalmology , vol.97 , pp. 358-366
    • Caprioli, J.1
  • 18
    • 0025963939 scopus 로고
    • Relation between optic nerve axon number and axon diameter to scleral canal area
    • Mikelberg FS, Yidegiligne HM, White VA, Schulzer M. Relation between optic nerve axon number and axon diameter to scleral canal area. Ophthalmology 1991;98: 60-3.
    • (1991) Ophthalmology , vol.98 , pp. 60-63
    • Mikelberg, F.S.1    Yidegiligne, H.M.2    White, V.A.3    Schulzer, M.4
  • 19
    • 0024495094 scopus 로고
    • The effect of age on normal human optic nerve fiber number and diameter
    • Repka MX, Quigley HA. The effect of age on normal human optic nerve fiber number and diameter. Ophthalmology 1989;96:26-32.
    • (1989) Ophthalmology , vol.96 , pp. 26-32
    • Repka, M.X.1    Quigley, H.A.2
  • 20
    • 0029738124 scopus 로고    scopus 로고
    • Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy
    • Zangwill LM, van Horn S, de Souza Lima M, Sample PA, Weinreb RN. Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy. Am J Ophthalmol 1996;122:520-5.
    • (1996) Am J Ophthalmol , vol.122 , pp. 520-525
    • Zangwill, L.M.1    Van Horn, S.2    De Souza Lima, M.3    Sample, P.A.4    Weinreb, R.N.5
  • 21
    • 0029804465 scopus 로고    scopus 로고
    • Detection of structural damage from glaucoma with confocal laser image analysis
    • Uchida H, Brigatti L, Caprioli J. Detection of structural damage from glaucoma with confocal laser image analysis. Invest Ophthalmol Vis Sci 1996;37:2393-401.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 2393-2401
    • Uchida, H.1    Brigatti, L.2    Caprioli, J.3
  • 23
    • 0030985497 scopus 로고    scopus 로고
    • The effect of optic disc size on diagnostic precision with the Heidelberg Retina Tomograph
    • Iester M, Mikelberg FS, Drance SM. The effect of optic disc size on diagnostic precision with the Heidelberg Retina Tomograph. Ophthalmology 1997;104:545-8.
    • (1997) Ophthalmology , vol.104 , pp. 545-548
    • Iester, M.1    Mikelberg, F.S.2    Drance, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.