메뉴 건너뛰기




Volumn 19, Issue 1, 1997, Pages 117-119

Interference with vancomycin fluorescence polarisation immunoassay in a nonuraemic patient

Author keywords

FPIA; Interference; Vancomycin

Indexed keywords

DRUG METABOLITE; VANCOMYCIN; VANCOMYCIN DERIVATIVE;

EID: 0031427816     PISSN: 01634356     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007691-199702000-00023     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0027272827 scopus 로고
    • Accuracy of vancomycin serum concentrations in patients with renal failure
    • Perino LM, Mueller BA. Accuracy of vancomycin serum concentrations in patients with renal failure. Ann Pharmacother 1993;27: 892-3.
    • (1993) Ann Pharmacother , vol.27 , pp. 892-893
    • Perino, L.M.1    Mueller, B.A.2
  • 2
    • 0024445877 scopus 로고
    • Potential problem with fluorescence polarisation immunoassay cross-reactivity to vancomycin degradation product CDP-1: Its detection in sera of renally impaired patients
    • Anne L, Hu M, Chan K, Colin L, Gottwald K. Potential problem with fluorescence polarisation immunoassay cross-reactivity to vancomycin degradation product CDP-1: its detection in sera of renally impaired patients. Ther Drug Monit 1989;11:585-9.
    • (1989) Ther Drug Monit , vol.11 , pp. 585-589
    • Anne, L.1    Hu, M.2    Chan, K.3    Colin, L.4    Gottwald, K.5
  • 3
    • 0025633623 scopus 로고
    • Measurement of vancomycin in renally impaired patient samples using a new high-performance liquid chromatography method with citamin B12 internal standard: Comparison of high-performance liquid chromatography, EMIT, and fluorescence polarisation immunoassay methods
    • Hu MW, Anne L, Forni T, Gottwald K. Measurement of vancomycin in renally impaired patient samples using a new high-performance liquid chromatography method with citamin B12 internal standard: comparison of high-performance liquid chromatography, EMIT, and fluorescence polarisation immunoassay methods. Ther Drug Monit 1990;12:562-9.
    • (1990) Ther Drug Monit , vol.12 , pp. 562-569
    • Hu, M.W.1    Anne, L.2    Forni, T.3    Gottwald, K.4
  • 4
    • 0023266377 scopus 로고
    • Overestimation of vancomycin concentrations utilising fluorescence polarisation immunoassay in patients on peritoneal dialysis
    • Morse GD, Nairn DK, Bertino JS, Walshe JJ. Overestimation of vancomycin concentrations utilising fluorescence polarisation immunoassay in patients on peritoneal dialysis. Ther Drug Monit 1987;9:212-5.
    • (1987) Ther Drug Monit , vol.9 , pp. 212-215
    • Morse, G.D.1    Nairn, D.K.2    Bertino, J.S.3    Walshe, J.J.4
  • 5
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron 1976;16:31-41.
    • (1976) Nephron , vol.16 , pp. 31-41
    • Cockroft, D.W.1    Gault, M.H.2
  • 7
    • 0028967964 scopus 로고
    • Therapeutic monitoring of antimicrobials: A summary of the information presented at the UK NEQAS for Antibiotic Assays meeting for participants, October 1993
    • Reeves DS, McGowan AP, Holt HA, Lovering AM, Warnock DW, White LO. Therapeutic monitoring of antimicrobials: a summary of the information presented at the UK NEQAS for Antibiotic Assays meeting for participants, October 1993. J Antimicrob Chemother 1995;35:213-26.
    • (1995) J Antimicrob Chemother , vol.35 , pp. 213-226
    • Reeves, D.S.1    McGowan, A.P.2    Holt, H.A.3    Lovering, A.M.4    Warnock, D.W.5    White, L.O.6
  • 8
    • 0030023189 scopus 로고    scopus 로고
    • Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarisation immunoassay
    • Morishige H, Shuto H, Ieiri I , Otsubo K, Oishi R. Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarisation immunoassay. Ther Drug Monit 1996;18:80-6.
    • (1996) Ther Drug Monit , vol.18 , pp. 80-86
    • Morishige, H.1    Shuto, H.2    Ieiri, I.3    Otsubo, K.4    Oishi, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.