메뉴 건너뛰기




Volumn 36, Issue 4-5, 1997, Pages 286-289

Arrhythmia curve interpretation using a dynamic system model of the myocardial pacemaker

Author keywords

Arrhythmia; High degree AV Block; Phase Response Curve; Ventricular Parasystole

Indexed keywords

ALGORITHM; ARTICLE; ATRIOVENTRICULAR BLOCK; COMPUTER SIMULATION; DYNAMICS; ELECTROCARDIOGRAM; HEART VENTRICLE EXTRASYSTOLE; HUMAN; MATHEMATICAL MODEL; PACEMAKER; PRIORITY JOURNAL; RR INTERVAL;

EID: 0031425702     PISSN: 00261270     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1636850     Document Type: Article
Times cited : (3)

References (8)
  • 1
    • 0017054228 scopus 로고
    • Effect of electrotonic potentials on pacemaker activity of canine Purkinje fibers in relation to parasystole
    • Jalife J, Moe GK. Effect of electrotonic potentials on pacemaker activity of canine Purkinje fibers in relation to parasystole. Circ Res 1976; 39: 801-8.
    • (1976) Circ Res , vol.39 , pp. 801-808
    • Jalife, J.1    Moe, G.K.2
  • 2
    • 0020961016 scopus 로고
    • Difference equation model of ventricular parasystole as an interaction between cardiac pacemakers based on the phase response curve
    • Ikeda N, Yoshizawa S, Sato T. Difference equation model of ventricular parasystole as an interaction between cardiac pacemakers based on the phase response curve. J Theor Biol 1983; 103: 439-65.
    • (1983) J Theor Biol , vol.103 , pp. 439-465
    • Ikeda, N.1    Yoshizawa, S.2    Sato, T.3
  • 3
    • 6844250486 scopus 로고
    • Dynamical system model of genesis of arrhythmias
    • in Japanese
    • Ikeda N. Dynamical system model of genesis of arrhythmias. BME 1995; 9: 60-71 (in Japanese).
    • (1995) BME , vol.9 , pp. 60-71
    • Ikeda, N.1
  • 4
    • 0024450336 scopus 로고
    • A computer-based model of parasystolic activity modulated by ventricular activation in the open-chest dog
    • Hoshino K, Ikeda N, Tanakadate A, Miyahara H. A computer-based model of parasystolic activity modulated by ventricular activation in the open-chest dog. J Electrocardiol 1989; 22: 277-83.
    • (1989) J Electrocardiol , vol.22 , pp. 277-283
    • Hoshino, K.1    Ikeda, N.2    Tanakadate, A.3    Miyahara, H.4
  • 6
    • 0021833228 scopus 로고
    • Intermittent ventricular bigeminy as an expression of modulated parasystole
    • Oreto G, Luzza F, Satullo G, Coglitore S, Schamroth L. Intermittent ventricular bigeminy as an expression of modulated parasystole. Am J Cardiol 1985; 55: 1634-7.
    • (1985) Am J Cardiol , vol.55 , pp. 1634-1637
    • Oreto, G.1    Luzza, F.2    Satullo, G.3    Coglitore, S.4    Schamroth, L.5
  • 7
    • 0022333386 scopus 로고
    • Rate-dependent, pacemaker-related, concealed ventricular extrasystoles: Entrainment of an ectopic ventricular focus
    • Klein HO, Sareli P, Kaplinski E, Schamroth L. Rate-dependent, pacemaker-related, concealed ventricular extrasystoles: Entrainment of an ectopic ventricular focus. Am Heart J 1985; 110: 165-8.
    • (1985) Am Heart J , vol.110 , pp. 165-168
    • Klein, H.O.1    Sareli, P.2    Kaplinski, E.3    Schamroth, L.4
  • 8
    • 0025790213 scopus 로고
    • Lower pacemaker in high degree atrioventricular block is modulated electronically by atrial excitations
    • Takayanagi K, Inoue T, Sakai Y. Lower pacemaker in high degree atrioventricular block is modulated electronically by atrial excitations. PACE 1991; 14: 1981-5.
    • (1991) PACE , vol.14 , pp. 1981-1985
    • Takayanagi, K.1    Inoue, T.2    Sakai, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.