-
1
-
-
0030119186
-
New dimensions of neurosurgery - The realm of high technology, possibilities, practicalities and realities
-
Appuzzo MW (1996) New dimensions of neurosurgery - The realm of high technology, possibilities, practicalities and realities. Neurosurgery 36:625-637.
-
(1996)
Neurosurgery
, vol.36
, pp. 625-637
-
-
Appuzzo, M.W.1
-
2
-
-
0027415882
-
Intraoperative localization using an armless, frameless stereotactic wand. Technical note
-
Barnett GH, Komos DW, Steiner CP, et al. (1993) Intraoperative localization using an armless, frameless stereotactic wand. Technical note. J Neurosurg 78:510-514.
-
(1993)
J Neurosurg
, vol.78
, pp. 510-514
-
-
Barnett, G.H.1
Komos, D.W.2
Steiner, C.P.3
-
4
-
-
0027423656
-
Use of a frameless armless Stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging
-
Barnett GH, Kormos DW, Steiner CP, et al. (1993) Use of a frameless armless Stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging. Neurosurgery 33:674-678.
-
(1993)
Neurosurgery
, vol.33
, pp. 674-678
-
-
Barnett, G.H.1
Kormos, D.W.2
Steiner, C.P.3
-
5
-
-
0027935823
-
Complications of CT-guided Stereotactic biopsy of intra-axial brain lesions
-
Bernstein M, Parrent A (1994) Complications of CT-guided Stereotactic biopsy of intra-axial brain lesions. J Neurosurg 81:165-168.
-
(1994)
J Neurosurg
, vol.81
, pp. 165-168
-
-
Bernstein, M.1
Parrent, A.2
-
6
-
-
0027530176
-
Extracranial application of the frameless Stereotactic operating microscope; experience with lumbar spine
-
Brodwater BK, Roberts DW, Nakajima T, et al. (1993) Extracranial application of the frameless Stereotactic operating microscope; experience with lumbar spine. Neurosurgery 32:209-213.
-
(1993)
Neurosurgery
, vol.32
, pp. 209-213
-
-
Brodwater, B.K.1
Roberts, D.W.2
Nakajima, T.3
-
8
-
-
0028238442
-
ISG Viewing Wand System, instrumentation, technique and technology
-
Drake JM, Rutka JT, Hoffman HJ, et al. (1994) ISG Viewing Wand System, instrumentation, technique and technology. Neurosurgery 34:1094.
-
(1994)
Neurosurgery
, vol.34
, pp. 1094
-
-
Drake, J.M.1
Rutka, J.T.2
Hoffman, H.J.3
-
9
-
-
0024474894
-
A frameless Stereotaxic operating microscope for neurosurgery
-
Friets EM, Strohbehn JW, Hatch JF, et al. (1989) A frameless Stereotaxic operating microscope for neurosurgery. IEEE Trans Biomed Eng 36:181-617.
-
(1989)
IEEE Trans Biomed Eng
, vol.36
, pp. 181-617
-
-
Friets, E.M.1
Strohbehn, J.W.2
Hatch, J.F.3
-
10
-
-
0026253881
-
The accuracies of four stereotactic frame systems; an independent assessment
-
Galloway RL Jr, Maciunas RJ, Latimer JW (1991) The accuracies of four stereotactic frame systems; an independent assessment. Biomed Instr Technol 25:457-460.
-
(1991)
Biomed Instr Technol
, vol.25
, pp. 457-460
-
-
Galloway Jr., R.L.1
Maciunas, R.J.2
Latimer, J.W.3
-
11
-
-
0029096705
-
The NeuroStation System for image-guided frameless stereotaxy
-
Germano IM (1995). The NeuroStation System for image-guided frameless stereotaxy. Neurosurgery 37:347.
-
(1995)
Neurosurgery
, vol.37
, pp. 347
-
-
Germano, I.M.1
-
12
-
-
0028141827
-
Frameless stereotaxy for surgery of the epilepsies
-
Germano IM, Olivier A, Cukiert A, et al. (1994) Frameless stereotaxy for surgery of the epilepsies. J Neurosurg 81:629-633.
-
(1994)
J Neurosurg
, vol.81
, pp. 629-633
-
-
Germano, I.M.1
Olivier, A.2
Cukiert, A.3
-
13
-
-
0029166311
-
Clinical use of a frameless stereotactic arm: Results of 325 cases
-
Golfinos JG, Fitzpatrick BC, Smith LR, et al. (1995) Clinical use of a frameless stereotactic arm: Results of 325 cases. J Neurosurg 83:197-205.
-
(1995)
J Neurosurg
, vol.83
, pp. 197-205
-
-
Golfinos, J.G.1
Fitzpatrick, B.C.2
Smith, L.R.3
-
14
-
-
0001624286
-
Frameless stereotaxy; computer interactive neurosurgery
-
Guthrie BL, Adler JR Jr (1991) Frameless stereotaxy; computer interactive neurosurgery. Perspect Neurol Surg 2:1-22.
-
(1991)
Perspect Neurol Surg
, vol.2
, pp. 1-22
-
-
Guthrie, B.L.1
Adler Jr., J.R.2
-
15
-
-
0026476872
-
Computer-assisted preoperative planning interactive surgery, and frameless stereotaxy
-
Guthrie BL, Adler JR Jr (1992) Computer-assisted preoperative planning interactive surgery, and frameless stereotaxy. Clin Neurosurg 38:112-131.
-
(1992)
Clin Neurosurg
, vol.38
, pp. 112-131
-
-
Guthrie, B.L.1
Adler Jr., J.R.2
-
16
-
-
0025735799
-
A frameless armless navigational system for computer-assisted neurosurgery. Technical note
-
Kato A, Yoshimine T, Hayakawa T, et al. (1991) A frameless armless navigational system for computer-assisted neurosurgery. Technical note. J Neurosurg 74:845-849.
-
(1991)
J Neurosurg
, vol.74
, pp. 845-849
-
-
Kato, A.1
Yoshimine, T.2
Hayakawa, T.3
-
17
-
-
0027258701
-
Ultrasound-controlled neuronavigator-guided brain surgery
-
Koivukangas J, Louhisalmi Y, Alakuijala J, et al. (1993) Ultrasound-controlled neuronavigator-guided brain surgery. J Neurosurg 79:36-42.
-
(1993)
J Neurosurg
, vol.79
, pp. 36-42
-
-
Koivukangas, J.1
Louhisalmi, Y.2
Alakuijala, J.3
-
18
-
-
0026652757
-
A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Experimental and clinical study
-
Kodzialka D, Dempsey PK, Lunsford LD, et al. (1992) A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Experimental and clinical study. Neurosurgery 30:402.
-
(1992)
Neurosurgery
, vol.30
, pp. 402
-
-
Kodzialka, D.1
Dempsey, P.K.2
Lunsford, L.D.3
-
19
-
-
0027074356
-
Computer assisted localizer for planning of surgery and intra-operative orientation
-
Laborde G, Gilsbach J, Harders A, et al. (1992) Computer assisted localizer for planning of surgery and intra-operative orientation. Acta Neurochir 119:166-170.
-
(1992)
Acta Neurochir
, vol.119
, pp. 166-170
-
-
Laborde, G.1
Gilsbach, J.2
Harders, A.3
-
20
-
-
0027209783
-
Frameless stereotactic drainage of intracranial abscess
-
Laborde G, Klimek L, Harders A, et al. (1993) Frameless stereotactic drainage of intracranial abscess. Surg Neurol 40:16-21.
-
(1993)
Surg Neurol
, vol.40
, pp. 16-21
-
-
Laborde, G.1
Klimek, L.2
Harders, A.3
-
21
-
-
0001287782
-
The Viewing Wand; a new system for three-dimensional CT correlated intra operative localization
-
Leggett WB, Greenberg MM, Gannon EA, et al. (1991) The Viewing Wand; a new system for three-dimensional CT correlated intra operative localization. Curr Surg 48:674-676.
-
(1991)
Curr Surg
, vol.48
, pp. 674-676
-
-
Leggett, W.B.1
Greenberg, M.M.2
Gannon, E.A.3
-
22
-
-
0028821714
-
Neuronavigation, computer-assisted surgery in Neurosurgery
-
Nabavi A, Manthei G, Blomer U, Kumpf L, Klimge H, Mehdom MM (1995) Neuronavigation, computer-assisted surgery in Neurosurgery. Radiologe 35:573-577.
-
(1995)
Radiologe
, vol.35
, pp. 573-577
-
-
Nabavi, A.1
Manthei, G.2
Blomer, U.3
Kumpf, L.4
Klimge, H.5
Mehdom, M.M.6
-
23
-
-
0028872080
-
The role of frameless stereotactic techniques in the treatment of paediatric CNS lesions
-
Pollock IF, Albright AL, Addson PD, Fitz CR (1995) The role of frameless stereotactic techniques in the treatment of paediatric CNS lesions. Paediatr Neurol 13:209-216.
-
(1995)
Paediatr Neurol
, vol.13
, pp. 209-216
-
-
Pollock, I.F.1
Albright, A.L.2
Addson, P.D.3
Fitz, C.R.4
-
24
-
-
0027509182
-
Sonic stereometry in microsurgical procedures for deep-seated tumors and vascular malformations
-
Reinhardt HF, Horstmann GA, Gratzl O (1993) Sonic stereometry in microsurgical procedures for deep-seated tumors and vascular malformations. Neurosurgery 32:51-57.
-
(1993)
Neurosurgery
, vol.32
, pp. 51-57
-
-
Reinhardt, H.F.1
Horstmann, G.A.2
Gratzl, O.3
-
25
-
-
0022505393
-
Frameless stereotactic integration of computerised topographic imaging and the operating microscope
-
Roberts DW, Stohbeln JW, Hatch JF, Murray W, Kettenberger AP (1986) Frameless stereotactic integration of computerised topographic imaging and the operating microscope. J Neurosurg 65:545-549.
-
(1986)
J Neurosurg
, vol.65
, pp. 545-549
-
-
Roberts, D.W.1
Stohbeln, J.W.2
Hatch, J.F.3
Murray, W.4
Kettenberger, A.P.5
-
26
-
-
0029902032
-
In vivo accuracy testing and clinical experience with the ISG viewing wand
-
Spios EP, Tebo SA, Zinreich SJ, Long DM, Bern H (1996) In vivo accuracy testing and clinical experience with the ISG viewing wand. Neurosurgery 39:194-202.
-
(1996)
Neurosurgery
, vol.39
, pp. 194-202
-
-
Spios, E.P.1
Tebo, S.A.2
Zinreich, S.J.3
Long, D.M.4
Bern, H.5
-
27
-
-
0028469070
-
The NeuroStation: A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery
-
Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation: A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imag Graphics 18:247-256.
-
(1994)
Comput Med Imag Graphics
, vol.18
, pp. 247-256
-
-
Smith, K.R.1
Frank, K.J.2
Bucholz, R.D.3
-
28
-
-
0028136945
-
Characterization of spacial distortion in magnetic resonance imaging and its implications for stereotactic surgery; technical special report
-
Sumanaweera TS, Adler JR Jr, Napel S, et al. (1994) Characterization of spacial distortion in magnetic resonance imaging and its implications for stereotactic surgery; technical special report. Neurosurgery 35:696.
-
(1994)
Neurosurgery
, vol.35
, pp. 696
-
-
Sumanaweera, T.S.1
Adler Jr., J.R.2
Napel, S.3
-
29
-
-
0027283958
-
A frameless Stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note
-
Tan KK, Grzeszczuk R, Levin DN, et al. (1993) A frameless Stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note. J Neurosurg 79:296-303.
-
(1993)
J Neurosurg
, vol.79
, pp. 296-303
-
-
Tan, K.K.1
Grzeszczuk, R.2
Levin, D.N.3
-
30
-
-
0025825270
-
Open surgery assisted by the neuronavigator, a stereotactic articulated sensitive arm
-
Watanabe E, Mayangi Y, Kosuji Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic articulated sensitive arm. Neurosurgery 28:792-800.
-
(1991)
Neurosurgery
, vol.28
, pp. 792-800
-
-
Watanabe, E.1
Mayangi, Y.2
Kosuji, Y.3
Manaka, S.4
Takakura, K.5
-
31
-
-
0023217523
-
Three-dimensional digitizer (neuronavigator); new equipment for computer tomography-guided stereotactic surgery
-
Watanabe E, Watanabe T, Manaka S, et al. (1987) Three-dimensional digitizer (neuronavigator); new equipment for computer tomography-guided stereotactic surgery. Surg Neurol 27:543-547.
-
(1987)
Surg Neurol
, vol.27
, pp. 543-547
-
-
Watanabe, E.1
Watanabe, T.2
Manaka, S.3
-
32
-
-
0030030322
-
A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with Leksell stereotactic system
-
Walton L, Hamshire A, Forster DMC, et al. (1996) A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with Leksell stereotactic system. Neurosurgery 38:170-176.
-
(1996)
Neurosurgery
, vol.38
, pp. 170-176
-
-
Walton, L.1
Hamshire, A.2
Forster, D.M.C.3
-
33
-
-
0030922136
-
Frameless stereotactic guidance for surgery of the upper cervical spine
-
Welch WC, Subach BR, Pollack IF, et al. (1997) Frameless stereotactic guidance for surgery of the upper cervical spine. Neurosurgery 40:958-963.
-
(1997)
Neurosurgery
, vol.40
, pp. 958-963
-
-
Welch, W.C.1
Subach, B.R.2
Pollack, I.F.3
-
34
-
-
0023237463
-
Application of robotics to stereotactic neurosurgery
-
Young RF (1987) Application of robotics to stereotactic neurosurgery. Neurol Res 9:123-128.
-
(1987)
Neurol Res
, vol.9
, pp. 123-128
-
-
Young, R.F.1
-
35
-
-
0027283759
-
Frameless stereotaxic integration of CT imaging data; accuracy and initial applications
-
Zinreich SJ, Tebo SA, Long DM, et al. (1993) Frameless stereotaxic integration of CT imaging data; accuracy and initial applications. Radiology 188:735-742.
-
(1993)
Radiology
, vol.188
, pp. 735-742
-
-
Zinreich, S.J.1
Tebo, S.A.2
Long, D.M.3
|