메뉴 건너뛰기




Volumn 2, Issue 5, 1997, Pages 292-297

Accuracy, efficacy, and clinical applications of the radionics operating arm system

Author keywords

Computer assisted guidance; Frameless stereotaxy; Image guidance; Neuronavigation; Stereotactic surgery

Indexed keywords

ACCURACY; ARTICLE; CRANIOTOMY; HUMAN; IMAGE PROCESSING; NEEDLE BIOPSY; NEUROSURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; STEREOTAXIC SURGERY; TUMOR LOCALIZATION;

EID: 0031424709     PISSN: 10929088     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0150(1997)2:5<292::AID-IGS5>3.0.CO;2-V     Document Type: Article
Times cited : (19)

References (35)
  • 1
    • 0030119186 scopus 로고    scopus 로고
    • New dimensions of neurosurgery - The realm of high technology, possibilities, practicalities and realities
    • Appuzzo MW (1996) New dimensions of neurosurgery - The realm of high technology, possibilities, practicalities and realities. Neurosurgery 36:625-637.
    • (1996) Neurosurgery , vol.36 , pp. 625-637
    • Appuzzo, M.W.1
  • 2
    • 0027415882 scopus 로고
    • Intraoperative localization using an armless, frameless stereotactic wand. Technical note
    • Barnett GH, Komos DW, Steiner CP, et al. (1993) Intraoperative localization using an armless, frameless stereotactic wand. Technical note. J Neurosurg 78:510-514.
    • (1993) J Neurosurg , vol.78 , pp. 510-514
    • Barnett, G.H.1    Komos, D.W.2    Steiner, C.P.3
  • 4
    • 0027423656 scopus 로고
    • Use of a frameless armless Stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging
    • Barnett GH, Kormos DW, Steiner CP, et al. (1993) Use of a frameless armless Stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging. Neurosurgery 33:674-678.
    • (1993) Neurosurgery , vol.33 , pp. 674-678
    • Barnett, G.H.1    Kormos, D.W.2    Steiner, C.P.3
  • 5
    • 0027935823 scopus 로고
    • Complications of CT-guided Stereotactic biopsy of intra-axial brain lesions
    • Bernstein M, Parrent A (1994) Complications of CT-guided Stereotactic biopsy of intra-axial brain lesions. J Neurosurg 81:165-168.
    • (1994) J Neurosurg , vol.81 , pp. 165-168
    • Bernstein, M.1    Parrent, A.2
  • 6
    • 0027530176 scopus 로고
    • Extracranial application of the frameless Stereotactic operating microscope; experience with lumbar spine
    • Brodwater BK, Roberts DW, Nakajima T, et al. (1993) Extracranial application of the frameless Stereotactic operating microscope; experience with lumbar spine. Neurosurgery 32:209-213.
    • (1993) Neurosurgery , vol.32 , pp. 209-213
    • Brodwater, B.K.1    Roberts, D.W.2    Nakajima, T.3
  • 8
    • 0028238442 scopus 로고
    • ISG Viewing Wand System, instrumentation, technique and technology
    • Drake JM, Rutka JT, Hoffman HJ, et al. (1994) ISG Viewing Wand System, instrumentation, technique and technology. Neurosurgery 34:1094.
    • (1994) Neurosurgery , vol.34 , pp. 1094
    • Drake, J.M.1    Rutka, J.T.2    Hoffman, H.J.3
  • 9
    • 0024474894 scopus 로고
    • A frameless Stereotaxic operating microscope for neurosurgery
    • Friets EM, Strohbehn JW, Hatch JF, et al. (1989) A frameless Stereotaxic operating microscope for neurosurgery. IEEE Trans Biomed Eng 36:181-617.
    • (1989) IEEE Trans Biomed Eng , vol.36 , pp. 181-617
    • Friets, E.M.1    Strohbehn, J.W.2    Hatch, J.F.3
  • 10
    • 0026253881 scopus 로고
    • The accuracies of four stereotactic frame systems; an independent assessment
    • Galloway RL Jr, Maciunas RJ, Latimer JW (1991) The accuracies of four stereotactic frame systems; an independent assessment. Biomed Instr Technol 25:457-460.
    • (1991) Biomed Instr Technol , vol.25 , pp. 457-460
    • Galloway Jr., R.L.1    Maciunas, R.J.2    Latimer, J.W.3
  • 11
    • 0029096705 scopus 로고
    • The NeuroStation System for image-guided frameless stereotaxy
    • Germano IM (1995). The NeuroStation System for image-guided frameless stereotaxy. Neurosurgery 37:347.
    • (1995) Neurosurgery , vol.37 , pp. 347
    • Germano, I.M.1
  • 12
    • 0028141827 scopus 로고
    • Frameless stereotaxy for surgery of the epilepsies
    • Germano IM, Olivier A, Cukiert A, et al. (1994) Frameless stereotaxy for surgery of the epilepsies. J Neurosurg 81:629-633.
    • (1994) J Neurosurg , vol.81 , pp. 629-633
    • Germano, I.M.1    Olivier, A.2    Cukiert, A.3
  • 13
    • 0029166311 scopus 로고
    • Clinical use of a frameless stereotactic arm: Results of 325 cases
    • Golfinos JG, Fitzpatrick BC, Smith LR, et al. (1995) Clinical use of a frameless stereotactic arm: Results of 325 cases. J Neurosurg 83:197-205.
    • (1995) J Neurosurg , vol.83 , pp. 197-205
    • Golfinos, J.G.1    Fitzpatrick, B.C.2    Smith, L.R.3
  • 14
    • 0001624286 scopus 로고
    • Frameless stereotaxy; computer interactive neurosurgery
    • Guthrie BL, Adler JR Jr (1991) Frameless stereotaxy; computer interactive neurosurgery. Perspect Neurol Surg 2:1-22.
    • (1991) Perspect Neurol Surg , vol.2 , pp. 1-22
    • Guthrie, B.L.1    Adler Jr., J.R.2
  • 15
    • 0026476872 scopus 로고
    • Computer-assisted preoperative planning interactive surgery, and frameless stereotaxy
    • Guthrie BL, Adler JR Jr (1992) Computer-assisted preoperative planning interactive surgery, and frameless stereotaxy. Clin Neurosurg 38:112-131.
    • (1992) Clin Neurosurg , vol.38 , pp. 112-131
    • Guthrie, B.L.1    Adler Jr., J.R.2
  • 16
    • 0025735799 scopus 로고
    • A frameless armless navigational system for computer-assisted neurosurgery. Technical note
    • Kato A, Yoshimine T, Hayakawa T, et al. (1991) A frameless armless navigational system for computer-assisted neurosurgery. Technical note. J Neurosurg 74:845-849.
    • (1991) J Neurosurg , vol.74 , pp. 845-849
    • Kato, A.1    Yoshimine, T.2    Hayakawa, T.3
  • 17
    • 0027258701 scopus 로고
    • Ultrasound-controlled neuronavigator-guided brain surgery
    • Koivukangas J, Louhisalmi Y, Alakuijala J, et al. (1993) Ultrasound-controlled neuronavigator-guided brain surgery. J Neurosurg 79:36-42.
    • (1993) J Neurosurg , vol.79 , pp. 36-42
    • Koivukangas, J.1    Louhisalmi, Y.2    Alakuijala, J.3
  • 18
    • 0026652757 scopus 로고
    • A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Experimental and clinical study
    • Kodzialka D, Dempsey PK, Lunsford LD, et al. (1992) A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Experimental and clinical study. Neurosurgery 30:402.
    • (1992) Neurosurgery , vol.30 , pp. 402
    • Kodzialka, D.1    Dempsey, P.K.2    Lunsford, L.D.3
  • 19
    • 0027074356 scopus 로고
    • Computer assisted localizer for planning of surgery and intra-operative orientation
    • Laborde G, Gilsbach J, Harders A, et al. (1992) Computer assisted localizer for planning of surgery and intra-operative orientation. Acta Neurochir 119:166-170.
    • (1992) Acta Neurochir , vol.119 , pp. 166-170
    • Laborde, G.1    Gilsbach, J.2    Harders, A.3
  • 20
    • 0027209783 scopus 로고
    • Frameless stereotactic drainage of intracranial abscess
    • Laborde G, Klimek L, Harders A, et al. (1993) Frameless stereotactic drainage of intracranial abscess. Surg Neurol 40:16-21.
    • (1993) Surg Neurol , vol.40 , pp. 16-21
    • Laborde, G.1    Klimek, L.2    Harders, A.3
  • 21
    • 0001287782 scopus 로고
    • The Viewing Wand; a new system for three-dimensional CT correlated intra operative localization
    • Leggett WB, Greenberg MM, Gannon EA, et al. (1991) The Viewing Wand; a new system for three-dimensional CT correlated intra operative localization. Curr Surg 48:674-676.
    • (1991) Curr Surg , vol.48 , pp. 674-676
    • Leggett, W.B.1    Greenberg, M.M.2    Gannon, E.A.3
  • 23
    • 0028872080 scopus 로고
    • The role of frameless stereotactic techniques in the treatment of paediatric CNS lesions
    • Pollock IF, Albright AL, Addson PD, Fitz CR (1995) The role of frameless stereotactic techniques in the treatment of paediatric CNS lesions. Paediatr Neurol 13:209-216.
    • (1995) Paediatr Neurol , vol.13 , pp. 209-216
    • Pollock, I.F.1    Albright, A.L.2    Addson, P.D.3    Fitz, C.R.4
  • 24
    • 0027509182 scopus 로고
    • Sonic stereometry in microsurgical procedures for deep-seated tumors and vascular malformations
    • Reinhardt HF, Horstmann GA, Gratzl O (1993) Sonic stereometry in microsurgical procedures for deep-seated tumors and vascular malformations. Neurosurgery 32:51-57.
    • (1993) Neurosurgery , vol.32 , pp. 51-57
    • Reinhardt, H.F.1    Horstmann, G.A.2    Gratzl, O.3
  • 25
    • 0022505393 scopus 로고
    • Frameless stereotactic integration of computerised topographic imaging and the operating microscope
    • Roberts DW, Stohbeln JW, Hatch JF, Murray W, Kettenberger AP (1986) Frameless stereotactic integration of computerised topographic imaging and the operating microscope. J Neurosurg 65:545-549.
    • (1986) J Neurosurg , vol.65 , pp. 545-549
    • Roberts, D.W.1    Stohbeln, J.W.2    Hatch, J.F.3    Murray, W.4    Kettenberger, A.P.5
  • 26
    • 0029902032 scopus 로고    scopus 로고
    • In vivo accuracy testing and clinical experience with the ISG viewing wand
    • Spios EP, Tebo SA, Zinreich SJ, Long DM, Bern H (1996) In vivo accuracy testing and clinical experience with the ISG viewing wand. Neurosurgery 39:194-202.
    • (1996) Neurosurgery , vol.39 , pp. 194-202
    • Spios, E.P.1    Tebo, S.A.2    Zinreich, S.J.3    Long, D.M.4    Bern, H.5
  • 27
    • 0028469070 scopus 로고
    • The NeuroStation: A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery
    • Smith KR, Frank KJ, Bucholz RD (1994) The NeuroStation: A highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. Comput Med Imag Graphics 18:247-256.
    • (1994) Comput Med Imag Graphics , vol.18 , pp. 247-256
    • Smith, K.R.1    Frank, K.J.2    Bucholz, R.D.3
  • 28
    • 0028136945 scopus 로고
    • Characterization of spacial distortion in magnetic resonance imaging and its implications for stereotactic surgery; technical special report
    • Sumanaweera TS, Adler JR Jr, Napel S, et al. (1994) Characterization of spacial distortion in magnetic resonance imaging and its implications for stereotactic surgery; technical special report. Neurosurgery 35:696.
    • (1994) Neurosurgery , vol.35 , pp. 696
    • Sumanaweera, T.S.1    Adler Jr., J.R.2    Napel, S.3
  • 29
    • 0027283958 scopus 로고
    • A frameless Stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note
    • Tan KK, Grzeszczuk R, Levin DN, et al. (1993) A frameless Stereotactic approach to neurosurgical planning based on retrospective patient-image registration. Technical note. J Neurosurg 79:296-303.
    • (1993) J Neurosurg , vol.79 , pp. 296-303
    • Tan, K.K.1    Grzeszczuk, R.2    Levin, D.N.3
  • 30
    • 0025825270 scopus 로고
    • Open surgery assisted by the neuronavigator, a stereotactic articulated sensitive arm
    • Watanabe E, Mayangi Y, Kosuji Y, Manaka S, Takakura K (1991) Open surgery assisted by the neuronavigator, a stereotactic articulated sensitive arm. Neurosurgery 28:792-800.
    • (1991) Neurosurgery , vol.28 , pp. 792-800
    • Watanabe, E.1    Mayangi, Y.2    Kosuji, Y.3    Manaka, S.4    Takakura, K.5
  • 31
    • 0023217523 scopus 로고
    • Three-dimensional digitizer (neuronavigator); new equipment for computer tomography-guided stereotactic surgery
    • Watanabe E, Watanabe T, Manaka S, et al. (1987) Three-dimensional digitizer (neuronavigator); new equipment for computer tomography-guided stereotactic surgery. Surg Neurol 27:543-547.
    • (1987) Surg Neurol , vol.27 , pp. 543-547
    • Watanabe, E.1    Watanabe, T.2    Manaka, S.3
  • 32
    • 0030030322 scopus 로고    scopus 로고
    • A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with Leksell stereotactic system
    • Walton L, Hamshire A, Forster DMC, et al. (1996) A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with Leksell stereotactic system. Neurosurgery 38:170-176.
    • (1996) Neurosurgery , vol.38 , pp. 170-176
    • Walton, L.1    Hamshire, A.2    Forster, D.M.C.3
  • 33
    • 0030922136 scopus 로고    scopus 로고
    • Frameless stereotactic guidance for surgery of the upper cervical spine
    • Welch WC, Subach BR, Pollack IF, et al. (1997) Frameless stereotactic guidance for surgery of the upper cervical spine. Neurosurgery 40:958-963.
    • (1997) Neurosurgery , vol.40 , pp. 958-963
    • Welch, W.C.1    Subach, B.R.2    Pollack, I.F.3
  • 34
    • 0023237463 scopus 로고
    • Application of robotics to stereotactic neurosurgery
    • Young RF (1987) Application of robotics to stereotactic neurosurgery. Neurol Res 9:123-128.
    • (1987) Neurol Res , vol.9 , pp. 123-128
    • Young, R.F.1
  • 35
    • 0027283759 scopus 로고
    • Frameless stereotaxic integration of CT imaging data; accuracy and initial applications
    • Zinreich SJ, Tebo SA, Long DM, et al. (1993) Frameless stereotaxic integration of CT imaging data; accuracy and initial applications. Radiology 188:735-742.
    • (1993) Radiology , vol.188 , pp. 735-742
    • Zinreich, S.J.1    Tebo, S.A.2    Long, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.