메뉴 건너뛰기




Volumn 29, Issue 6, 1997, Pages 374-377

Widening of the anterior chamber angle after laser iridotomy proven by Scheimpflug imaging technique

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; CLINICAL ARTICLE; CLOSED ANGLE GLAUCOMA; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE PROCESSING; IRIDOTOMY; LASER SURGERY; MALE; NEODYMIUM LASER; PRIORITY JOURNAL; SLIT LAMP;

EID: 0031424676     PISSN: 10794794     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0042629953 scopus 로고
    • Chamber angle and biometric study in PACG and its lens
    • Krieglstein GK ed. Heidelberg, Germany: Kanden Verlag
    • Hung PT, Hou CY, Lan WL, Tsai CB, Liang KY. Chamber angle and biometric study in PACG and its lens. In: Krieglstein GK ed. Glaucoma Update. Volume 5. Heidelberg, Germany: Kanden Verlag. 1995:309-315.
    • (1995) Glaucoma Update , vol.5 , pp. 309-315
    • Hung, P.T.1    Hou, C.Y.2    Lan, W.L.3    Tsai, C.B.4    Liang, K.Y.5
  • 2
    • 0004257968 scopus 로고
    • Baltimore, MD: Williams & Wilkins
    • Shields MB. Textbook of Glaucoma. Baltimore, MD: Williams & Wilkins; 1992:165.
    • (1992) Textbook of Glaucoma , pp. 165
    • Shields, M.B.1
  • 3
    • 0345765634 scopus 로고
    • Outpatient argon laser iridotomy for angle-closure glaucoma: A two-year study
    • Abraham RK, Miller GL. Outpatient argon laser iridotomy for angle-closure glaucoma: a two-year study. Trans Am Acad Ophthalmol Otolaryngol. 1975;79:529-538.
    • (1975) Trans am Acad Ophthalmol Otolaryngol. , vol.79 , pp. 529-538
    • Abraham, R.K.1    Miller, G.L.2
  • 4
    • 0023140090 scopus 로고
    • Neodymium-YAG laser iridectomy in the treatment and prevention of angle closure glaucoma: A review of 373 eyes
    • Tomey KF, Traverso CE, Shammas IV. Neodymium-YAG laser iridectomy in the treatment and prevention of angle closure glaucoma: a review of 373 eyes. Arch Ophthalmol. 1987;105:476-181.
    • (1987) Arch Ophthalmol. , vol.105 , pp. 476-1181
    • Tomey, K.F.1    Traverso, C.E.2    Shammas, I.V.3
  • 5
    • 0344106518 scopus 로고
    • Central anterior chamber depth after laser iridectomy
    • Jacobs IH, Krohn DL. Central anterior chamber depth after laser iridectomy. Am J Ophthalmol. 1980;43:169-176.
    • (1980) Am J Ophthalmol. , vol.43 , pp. 169-176
    • Jacobs, I.H.1    Krohn, D.L.2
  • 6
    • 0344969011 scopus 로고
    • Peripheral chamber depth in shallow anterior chamber
    • Tornquist R. Peripheral chamber depth in shallow anterior chamber. Br J Ophthalmol. 1959;43:169-176.
    • (1959) Br J Ophthalmol. , vol.43 , pp. 169-176
    • Tornquist, R.1
  • 7
    • 0021348982 scopus 로고
    • Anterior chamber dimension in patients with narrow angles and angle-closure glaucoma
    • Lee DA, Brubaker RF, Ilstrup DM. Anterior chamber dimension in patients with narrow angles and angle-closure glaucoma. Arch Ophthalmol. 1984;102:46-50.
    • (1984) Arch Ophthalmol. , vol.102 , pp. 46-50
    • Lee, D.A.1    Brubaker, R.F.2    Ilstrup, D.M.3
  • 8
    • 0025100074 scopus 로고
    • The effect of iridotomy on iris contour
    • Jim JC, Anderson DR. The effect of iridotomy on iris contour. Am J Ophthalmol. 1990;110:260-263.
    • (1990) Am J Ophthalmol. , vol.110 , pp. 260-263
    • Jim, J.C.1    Anderson, D.R.2
  • 9
    • 0024237291 scopus 로고
    • A method for improved biometry of the anterior chamber with a Scheimpflug technique
    • Richard DW, Russell SR, Anderson DR. A method for improved biometry of the anterior chamber with a Scheimpflug technique. Invest Ophthalmol Vis Sci. 1988;29:1826-1835.
    • (1988) Invest Ophthalmol Vis Sci. , vol.29 , pp. 1826-1835
    • Richard, D.W.1    Russell, S.R.2    Anderson, D.R.3
  • 10
    • 0025326509 scopus 로고
    • The multipurpose camera: A new anterior segment analysis system
    • Sasaki K, Sakamoto Y, Shibata T, Yasufumi E. The multipurpose camera: a new anterior segment analysis system. Ophthalmic Res. 1990;22:(suppl 1):3-8.
    • (1990) Ophthalmic Res. , vol.22 , Issue.1 SUPPL. , pp. 3-8
    • Sasaki, K.1    Sakamoto, Y.2    Shibata, T.3    Yasufumi, E.4
  • 11
    • 0025326513 scopus 로고
    • Quantitative chamber angle measurement utilizing image-processing techniques
    • Shibata T, Sasaki K, Sakamoto Y, Takahashi N. Quantitative chamber angle measurement utilizing image-processing techniques. Ophthalmic Res. 1990;22(suppl 1): 81-84.
    • (1990) Ophthalmic Res. , vol.22 , Issue.1 SUPPL. , pp. 81-84
    • Shibata, T.1    Sasaki, K.2    Sakamoto, Y.3    Takahashi, N.4
  • 12
    • 0344969009 scopus 로고
    • Reproducibility of quantitative anterior chamber angle measurements with Scheimpflug video imaging
    • Bosem ME, Morsman D, Lusky M, Weinreb RN: Reproducibility of quantitative anterior chamber angle measurements with Scheimpflug video imaging. J Glaucoma. 1992;1:254-257.
    • (1992) J Glaucoma. , vol.1 , pp. 254-257
    • Bosem, M.E.1    Morsman, D.2    Lusky, M.3    Weinreb, R.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.