메뉴 건너뛰기




Volumn 25, Issue 5, 1997, Pages 459-463

Continuous measurement of arterial and end-tidal carbon dioxide during cardiac surgery: P(a-ET)CO2 gradient

Author keywords

Anaesthesia: monitoring, blood gas sensors, capnography, cardiac surgery

Indexed keywords

ARTERIAL CARBON DIOXIDE TENSION; ARTICLE; BLOOD GAS; CAPNOGRAPHY; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CONTROLLED STUDY; END TIDAL CARBON DIOXIDE TENSION; HEART SURGERY; HUMAN; PATIENT MONITORING; SENSOR;

EID: 0031422742     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x9702500501     Document Type: Article
Times cited : (11)

References (17)
  • 2
    • 0025198394 scopus 로고
    • 2 difference during cardiothoracic surgery
    • 2 difference during cardiothoracic surgery. J Cardiothorac Vasc Anesth 1990; 4:105-117.
    • (1990) J Cardiothorac Vasc Anesth , vol.4 , pp. 105-117
    • Fletcher, R.1
  • 4
    • 0028214567 scopus 로고
    • A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation
    • Venkatesh B, Clutton-Brock TH, Hendry SP. A multiparameter sensor for continuous intra-arterial blood gas monitoring: a prospective evaluation. Crit Care Med 1994; 22:588-594.
    • (1994) Crit Care Med , vol.22 , pp. 588-594
    • Venkatesh, B.1    Clutton-Brock, T.H.2    Hendry, S.P.3
  • 5
    • 0020597861 scopus 로고
    • Variability of arterial blood gas values in stable patients in the ICU
    • Thorson SH, Marini JJ, Pierson DJ, Hudson LD. Variability of arterial blood gas values in stable patients in the ICU. Chest 1983; 84:14-18.
    • (1983) Chest , vol.84 , pp. 14-18
    • Thorson, S.H.1    Marini, J.J.2    Pierson, D.J.3    Hudson, L.D.4
  • 6
    • 72849165961 scopus 로고
    • 2 tension difference in anaesthetized man
    • 2 tension difference in anaesthetized man. J Appl Physiol 1960; 15:383-389.
    • (1960) J Appl Physiol , vol.15 , pp. 383-389
    • Nunn, J.F.1    Hill, D.W.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0022634158 scopus 로고
    • Changes in functional residual capacity during cardiac surgery
    • Johnmarker C, Nordstron L, Werner O. Changes in functional residual capacity during cardiac surgery. Br J Anaesth 1986; 58:428-432.
    • (1986) Br J Anaesth , vol.58 , pp. 428-432
    • Johnmarker, C.1    Nordstron, L.2    Werner, O.3
  • 14
    • 0028917137 scopus 로고
    • Effect of cardiopulmonary bypass on hand and forearm blood flow
    • Pauca AL, Kon ND, Cordell AR. Effect of cardiopulmonary bypass on hand and forearm blood flow. Br J Anaesth 1995; 74:287-292.
    • (1995) Br J Anaesth , vol.74 , pp. 287-292
    • Pauca, A.L.1    Kon, N.D.2    Cordell, A.R.3
  • 17
    • 0025032771 scopus 로고
    • Progress in the development of a fluorescent intravascular blood gas system in man
    • Mahutte CK, Sassoon CSH, Muro JR, et al. Progress in the development of a fluorescent intravascular blood gas system in man. J Clin Monit 1990; 6:147-157.
    • (1990) J Clin Monit , vol.6 , pp. 147-157
    • Mahutte, C.K.1    Sassoon, C.S.H.2    Muro, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.