메뉴 건너뛰기




Volumn 33, Issue , 1997, Pages 30-34

A DSP based real time system for analysis of Bundle of HIS and Late Potentials using wavelet transforms

Author keywords

Digital signal processing; ECG; His Purkinje; Late potentials; Multiresolution analysis; Wavelet transform

Indexed keywords

ANALYSIS; BODY SURFACE; COMPUTER; CONFERENCE PAPER; ELECTRIC POTENTIAL; HEART RATE VARIABILITY; HIS BUNDLE; RECORDING; SIGNAL PROCESSING;

EID: 0031411591     PISSN: 00678856     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (16)
  • 1
    • 0016598069 scopus 로고
    • His Bundle Electrocardiography
    • Hill D.W. and Watson, B.M. (Eds.), Peter Peregrinus, Stevenage
    • Furness, A. His Bundle Electrocardiography. In IEE Medical Electronics Monographs 13-17. Hill D.W. and Watson, B.M. (Eds.), Peter Peregrinus, Stevenage, 48-85, 1975.
    • (1975) IEE Medical Electronics Monographs , vol.13-17 , pp. 48-85
    • Furness, A.1
  • 2
    • 0015608462 scopus 로고
    • His-bundle Electrocardiogram
    • Haft, J.I. His-bundle Electrocardiogram. Circulation 47, 897-911, 1973.
    • (1973) Circulation , vol.47 , pp. 897-911
    • Haft, J.I.1
  • 3
    • 0021246813 scopus 로고
    • Non-invasive beat-by-beat registration of ventricular late potentials using high resolution electrocardiography
    • Hombach, V., Kebbel, U., Hopp, H.W., Winter, U. and Hirche, H. Non-invasive beat-by-beat registration of ventricular late potentials using high resolution electrocardiography. Int. J. Cardiology., 6, 167-183, 1984
    • (1984) Int. J. Cardiology , vol.6 , pp. 167-183
    • Hombach, V.1    Kebbel, U.2    Hopp, H.W.3    Winter, U.4    Hirche, H.5
  • 4
    • 0027628260 scopus 로고
    • Detection of late potentials in the signal-averaged ECG combining time and frequency domain analysis
    • Gramatikov, B. I., Detection of late potentials in the signal-averaged ECG combining time and frequency domain analysis Med. & Biol. Eng. & Comput., 31, pp. 333-339, 1993
    • (1993) Med. & Biol. Eng. & Comput. , vol.31 , pp. 333-339
    • Gramatikov, B.I.1
  • 6
    • 0023870602 scopus 로고
    • Beat-to-beat detection of His-Purkinje system signals using adaptive filters
    • Al-Nashash, H. A. M., Kelly, S. W. and Taylor, D. J. E. Beat-to-beat detection of His-Purkinje system signals using adaptive filters. Med. & Biol. Eng. & Comput., 26, 117-125, 1988.
    • (1988) Med. & Biol. Eng. & Comput. , vol.26 , pp. 117-125
    • Al-Nashash, H.A.M.1    Kelly, S.W.2    Taylor, D.J.E.3
  • 7
    • 0018331034 scopus 로고
    • The effect of filtering the His-Purkinje system electrocardiogram
    • Berbari, E. J., Lazzara, R. and Scherlag, B. J. The effect of filtering the His-Purkinje system electrocardiogram. IEEE Trans., BME-26, 82-85, 1979.
    • (1979) IEEE Trans. , vol.BME-26 , pp. 82-85
    • Berbari, E.J.1    Lazzara, R.2    Scherlag, B.J.3
  • 8
    • 0019436210 scopus 로고
    • Surface recording of His-Purkinje activity on an every beat basis without digital averaging
    • Flowers, N. C., Shvartsman, B.M., Kennelly, B. M., Sohi, G. S. and Horan, L. G. Surface recording of His-Purkinje activity on an every beat basis without digital averaging. Circulation 63, 948-952, 1981.
    • (1981) Circulation , vol.63 , pp. 948-952
    • Flowers, N.C.1    Shvartsman, B.M.2    Kennelly, B.M.3    Sohi, G.S.4    Horan, L.G.5
  • 9
    • 0037888702 scopus 로고
    • The wavelet transform - A method of time frequency localization
    • S Haykin, Ed. New York, Prentice Hall
    • Daubechies, I., "The wavelet transform - A method of time frequency localization", Advances in Spectral Analysis. S Haykin, Ed. New York, Prentice Hall, 1990.
    • (1990) Advances in Spectral Analysis
    • Daubechies, I.1
  • 10
    • 0024904699 scopus 로고
    • Multiresolution frequency channel decomposition of images and wavelet models
    • Mallat, S., "Multiresolution frequency channel decomposition of images and wavelet models", IEEE Trans. Acoust, Speech Signal Processing, 37, No. 12, pp. 2091-2110, 1989.
    • (1989) IEEE Trans. Acoust, Speech Signal Processing , vol.37 , Issue.12 , pp. 2091-2110
    • Mallat, S.1
  • 13
    • 0027382249 scopus 로고
    • Wavelet analysis of high resolution signal averaged ECGs in post infarction patients
    • Morlet, D., Peyrin, P., Dessegine, P., Touboul, and Rubul, P. "Wavelet analysis of high resolution signal averaged ECGs in post infarction patients" J. Electrocard. vol. 26, pp. 311-320, 1993
    • (1993) J. Electrocard. , vol.26 , pp. 311-320
    • Morlet, D.1    Peyrin, P.2    Dessegine, P.3    Touboul4    Rubul, P.5
  • 14
    • 0028389430 scopus 로고
    • Digital Signal processing system for real time HIS bundle and late potential measurement
    • Pepper. A, Digital Signal processing system for real time HIS bundle and late potential measurement, Med. & Biol. Eng. & Comput., Vol. 32, pp. 239-40, 1994.
    • (1994) Med. & Biol. Eng. & Comput. , vol.32 , pp. 239-240
    • Pepper, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.