Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility-induced artifacts

Author keywords

Artifact; Functional MRI; Image registration; Susceptibility

Indexed keywords

ALGORITHM; ANALYTIC METHOD; ARTICLE; ARTIFACT; BRAIN FUNCTION; CADAVER; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN BLOOD LEVEL; PHANTOM; PRIORITY JOURNAL;

EID: 0031400794     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880070219     Document Type: Article
Times cited : (67)

References (12)
  • 1
    • 0025336246 scopus 로고
    • Oxygen-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
    • Ogawa S, Lee T, Nasask AS, Glynn P. Oxygen-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields. Magn Reson Med 1990; 14:68-78.
    • (1990) Magn Reson Med , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.2    Nasask, A.S.3    Glynn, P.4
  • 3
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods RP, Cherry SR, Mazziota JC. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 1992; 16:620-633.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziota, J.C.3
  • 5
    • 0027265576 scopus 로고
    • Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5T: [AGC1] preliminary results
    • Lai S, Hopkins AL, Haacke EM, et al. Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5T: [AGC1] preliminary results. Magn Reson Med 1993; 30: 387-392.
    • (1993) Magn Reson Med , vol.30 , pp. 387-392
    • Lai, S.1    Hopkins, A.L.2    Haacke, E.M.3
  • 7
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygen level dependent contrast magnetic resonance imaging: A comparison of signal characteristics with a biophysical model
    • Ogawa S, Menon RS, Tank DW, et al. Functional brain mapping by blood oxygen level dependent contrast magnetic resonance imaging: a comparison of signal characteristics with a biophysical model. Biophys J 1993; 64:803-812.
    • (1993) Biophys J , vol.64 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3
  • 8
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: Theory and experiment
    • Weiskoff RM, Zuo CS, Boxerman JL, Rosen BR. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn Reson Med 1994; 31:601-610.
    • (1994) Magn Reson Med , vol.31 , pp. 601-610
    • Weiskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 9
    • 0029055315 scopus 로고
    • The intravascular contribution to fMRI signal change: Monte Carlo modeling and diffusion weighted studies in vivo
    • Boxerman JL, Bandettini PA, Kwong KK, et al. The intravascular contribution to fMRI signal change: Monte Carlo modeling and diffusion weighted studies in vivo. Magn Reson Med 1995; 34: 4-10.
    • (1995) Magn Reson Med , vol.34 , pp. 4-10
    • Boxerman, J.L.1    Bandettini, P.A.2    Kwong, K.K.3
  • 10
    • 0027973923 scopus 로고
    • Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
    • Yablonskiy D, Haacke EM. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn Reson Med 1994; 32:749-763.
    • (1994) Magn Reson Med , vol.32 , pp. 749-763
    • Yablonskiy, D.1    Haacke, E.M.2
  • 11
    • 8044230478 scopus 로고
    • o field mapping in the human head: Comparison of global distributions and local field histograms using finite element calculations with phase contrast images
    • Nice: Society of Magnetic Resonance
    • o field mapping in the human head: comparison of global distributions and local field histograms using finite element calculations with phase contrast images. Presented at the 3rd annual meeting of the Society of Magnetic Resonance. Nice: Society of Magnetic Resonance, 1995; 731.
    • (1995) 3rd Annual Meeting of the Society of Magnetic Resonance , pp. 731
    • Li, S.1    Dardzinski, B.J.2    Collins, C.M.3    Williams, G.D.4    Yang, Q.X.5    Smith, M.B.6
  • 12
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MR1 of the human brain
    • Bandettini PA, Jesmanowicz A, Wong EC, Hyde JS. Processing strategies for time-course data sets in functional MR1 of the human brain. Magn Reson Med 1993; 30:161-173.
    • (1993) Magn Reson Med , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.