메뉴 건너뛰기




Volumn 7, Issue 2, 1997, Pages 316-320

Three-dimensional coronary angiography of the perfused rat heart

Author keywords

Coronary angiography; MR angiography; Rat heart; Visualization

Indexed keywords

ANGIOCARDIOGRAPHY; ANGIOGRAPHY; ANIMAL TISSUE; ARTERY BLOOD FLOW; ARTICLE; CONTRAST ENHANCEMENT; DIAGNOSTIC IMAGING; HYSTERESIS; ISOLATED HEART; LEFT CORONARY ARTERY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RAT; THREE DIMENSIONAL IMAGING;

EID: 0031400793     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880070211     Document Type: Article
Times cited : (5)

References (19)
  • 3
    • 0025896256 scopus 로고
    • NMR angiography of coronary vessels with 2-D planar image scanning
    • Cho ZH, Mun CW, Friedenberg RM. NMR angiography of coronary vessels with 2-D planar image scanning. Magn Reson Med 1991; 20:134-143.
    • (1991) Magn Reson Med , vol.20 , pp. 134-143
    • Cho, Z.H.1    Mun, C.W.2    Friedenberg, R.M.3
  • 4
    • 0025875174 scopus 로고
    • Coronary angiography using fast selective inversion recovery
    • Wang JW, Hu BS, Macowski A, Nishimura DG. Coronary angiography using fast selective inversion recovery. Magn Reson Med 1991; 18:417-423.
    • (1991) Magn Reson Med , vol.18 , pp. 417-423
    • Wang, J.W.1    Hu, B.S.2    Macowski, A.3    Nishimura, D.G.4
  • 6
  • 7
    • 0026151237 scopus 로고
    • MR imaging of coronary artery flow in isolated and in vivo hearts
    • Burstein D. MR imaging of coronary artery flow in isolated and in vivo hearts. J Magn Reson Imaging 1991; 1:337-346.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 337-346
    • Burstein, D.1
  • 8
    • 0021741851 scopus 로고
    • Blood flow effects in magnetic resonance imaging
    • Axel L. Blood flow effects In magnetic resonance imaging. Am J Roentgenol 1984; 143:1157-1166.
    • (1984) Am J Roentgenol , vol.143 , pp. 1157-1166
    • Axel, L.1
  • 9
    • 0023217321 scopus 로고
    • Improving MR Image quality in the presence of motion by using rephasing gradients
    • Haacke EM, Lenz GW. Improving MR Image quality in the presence of motion by using rephasing gradients. Am J Roentgenol 1987; 148:1251-1258.
    • (1987) Am J Roentgenol , vol.148 , pp. 1251-1258
    • Haacke, E.M.1    Lenz, G.W.2
  • 10
    • 0023913360 scopus 로고
    • MR angiography with gradient motion refocussing
    • Laub GA, Kaiser WA. MR angiography with gradient motion refocussing. J Comput Assist Tomogr 1989; 12:377-382.
    • (1989) J Comput Assist Tomogr , vol.12 , pp. 377-382
    • Laub, G.A.1    Kaiser, W.A.2
  • 11
    • 0024573913 scopus 로고
    • Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
    • Wolff SD, Balaban RS. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn Reson Med 1989; 10:135-144.
    • (1989) Magn Reson Med , vol.10 , pp. 135-144
    • Wolff, S.D.1    Balaban, R.S.2
  • 12
    • 0026877891 scopus 로고
    • Magnetization transfer time-of-flight magnetic resonance angiography
    • Pike GB, Hu BS, Glover GH, Enzmann DR. Magnetization transfer time-of-flight magnetic resonance angiography. Magn Reson Med 1992; 25:372-379.
    • (1992) Magn Reson Med , vol.25 , pp. 372-379
    • Pike, G.B.1    Hu, B.S.2    Glover, G.H.3    Enzmann, D.R.4
  • 13
    • 0027280275 scopus 로고
    • Coronary arteries: Three-dimensional MR Imaging with fat saturation and magnetization transfer contrast
    • Li D, Paschal CB, Haacke EM, Adler LP. Coronary arteries: three-dimensional MR Imaging with fat saturation and magnetization transfer contrast. Radiology 1993; 187:401-406.
    • (1993) Radiology , vol.187 , pp. 401-406
    • Li, D.1    Paschal, C.B.2    Haacke, E.M.3    Adler, L.P.4
  • 14
    • 0027439656 scopus 로고
    • Intracranial MR angiography: Application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity compensated sequences
    • Lin W, Tkach JA, Haacke EM, Masaryk TJ. Intracranial MR angiography: application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity compensated sequences. Radiology 1993; 186:753-761.
    • (1993) Radiology , vol.186 , pp. 753-761
    • Lin, W.1    Tkach, J.A.2    Haacke, E.M.3    Masaryk, T.J.4
  • 15
    • 0026500231 scopus 로고
    • Contrast-to-noise ratios in maximum Intensity projection images
    • Brown DG, Riederer SJ. Contrast-to-noise ratios In maximum Intensity projection images. Magn Reson Med 1992; 23:130-137.
    • (1992) Magn Reson Med , vol.23 , pp. 130-137
    • Brown, D.G.1    Riederer, S.J.2
  • 16
  • 18
    • 0023381475 scopus 로고
    • Marching cubes: A high resolution 3D surface reconstruction algorithm
    • Lorensen WE, Cline HE. Marching cubes: a high resolution 3D surface reconstruction algorithm. Computer Graphics (ACM SIG-Graph) 1987; 21:163-169.
    • (1987) Computer Graphics (ACM SIG-Graph) , vol.21 , pp. 163-169
    • Lorensen, W.E.1    Cline, H.E.2
  • 19
    • 0029325940 scopus 로고
    • Fast generation of leakproof surfaces from well-defined objects by a modified marching cubes algorithm
    • Roll S, Haase A, von Kienlin M. Fast generation of leakproof surfaces from well-defined objects by a modified marching cubes algorithm. Computer Graphics Forum 1995; 14:127-138.
    • (1995) Computer Graphics Forum , vol.14 , pp. 127-138
    • Roll, S.1    Haase, A.2    Von Kienlin, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.