메뉴 건너뛰기




Volumn 7, Issue 3, 1997, Pages 512-517

High resolution T2-weighted imaging of the human brain using surface coils and an analytical reception profile correction

Author keywords

B1 field mapping; Brain; Fast spin echo (FSE); High resolution; Image intensity correction; Surface coil

Indexed keywords

ALGORITHM; ARTICLE; BRAIN CORTEX; ELECTRON SPIN RESONANCE; IMAGE PROCESSING; IMAGE RECONSTRUCTION; INTERNAL AUDITORY CANAL; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO;

EID: 0031397674     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880070310     Document Type: Article
Times cited : (10)

References (25)
  • 2
    • 0027158670 scopus 로고
    • Three dimensional MR gradient recalled echo imaging of the inner ear: Comparison of FID and echo imaging techniques
    • Tien RD, Felsberg GJ, MacFall J. Three dimensional MR gradient recalled echo imaging of the inner ear: comparison of FID and echo imaging techniques. Magn Reson Imaging 1993; 11:429-435.
    • (1993) Magn Reson Imaging , vol.11 , pp. 429-435
    • Tien, R.D.1    Felsberg, G.J.2    MacFall, J.3
  • 3
    • 0028794978 scopus 로고
    • Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method
    • Ying K, Schmalbrock P, Clymer B. Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method. Magn Reson Med 1995; 33:82-87.
    • (1995) Magn Reson Med , vol.33 , pp. 82-87
    • Ying, K.1    Schmalbrock, P.2    Clymer, B.3
  • 4
    • 0026574430 scopus 로고
    • High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition
    • Foo TKF, Shellock FG, Hayes CE, Schenck JF, Slayman BE. High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition. Radiology 1992; 183:277-281.
    • (1992) Radiology , vol.183 , pp. 277-281
    • Foo, T.K.F.1    Shellock, F.G.2    Hayes, C.E.3    Schenck, J.F.4    Slayman, B.E.5
  • 5
  • 6
    • 0028355099 scopus 로고
    • Fast spin echo MRI in otology
    • Phelps P. Fast spin echo MRI in otology. J Laryngol Otol 1994; 108:383-394.
    • (1994) J Laryngol Otol , vol.108 , pp. 383-394
    • Phelps, P.1
  • 7
    • 0029682455 scopus 로고    scopus 로고
    • High resolution 3D imaging of the inner ear with a modified fast spin echo pulse sequence
    • Lee JN, King BD. Parker DL, Buswell HR, Harnsberger HR. High resolution 3D imaging of the inner ear with a modified fast spin echo pulse sequence. JMRI 1996; 6(1):223-225.
    • (1996) JMRI , vol.6 , Issue.1 , pp. 223-225
    • Lee, J.N.1    King, B.D.2    Parker, D.L.3    Buswell, H.R.4    Harnsberger, H.R.5
  • 10
    • 0343356651 scopus 로고
    • Surface coil Intensity correction using homomorphic filtering
    • New York: Society of Magnetic Resonance in Medicine
    • Fuderer M, van Est A. Surface coil Intensity correction using homomorphic filtering (abstract). In: Book of abstracts: Society of Magnetic Resonance in Medicine 1987. New York: Society of Magnetic Resonance in Medicine, 1987; 266.
    • (1987) Book of Abstracts: Society of Magnetic Resonance in Medicine 1987 , pp. 266
    • Fuderer, M.1    Van Est, A.2
  • 11
    • 0025362870 scopus 로고
    • Automatische korrektur des Signalabfalls von oberflachenspulen
    • Zanella FE, Lanfermann H. Bunke J. Automatische korrektur des Signalabfalls von oberflachenspulen. Radiologe 1990; 30: 223-227.
    • (1990) Radiologe , vol.30 , pp. 223-227
    • Zanella, F.E.1    Lanfermann, H.2    Bunke, J.3
  • 12
    • 0022863971 scopus 로고
    • An algorithm for compensation of surface-coil images for sensitivity of the surface coil
    • Haselgrove J, Prammer M. An algorithm for compensation of surface-coil images for sensitivity of the surface coil. Magn Reson Imaging 1986; 4:469-472.
    • (1986) Magn Reson Imaging , vol.4 , pp. 469-472
    • Haselgrove, J.1    Prammer, M.2
  • 13
    • 0023940563 scopus 로고
    • Compensation for surface coil sensitivity variation in magnetic resonance imaging
    • Narayana PA, Brey WW, Kulkami MV, Sievenpiper CL. Compensation for surface coil sensitivity variation in magnetic resonance imaging. Magn Reson Imaging 1988: 6:271-274.
    • (1988) Magn Reson Imaging , vol.6 , pp. 271-274
    • Narayana, P.A.1    Brey, W.W.2    Kulkami, M.V.3    Sievenpiper, C.L.4
  • 14
    • 0023913522 scopus 로고
    • Correction for intensity falloff in surface coil magnetic resonance imaging
    • Brey WW, Narayana PA. Correction for intensity falloff in surface coil magnetic resonance imaging. Med Phys 1988; 15:241-245.
    • (1988) Med Phys , vol.15 , pp. 241-245
    • Brey, W.W.1    Narayana, P.A.2
  • 15
    • 0029265843 scopus 로고
    • Surface coil MRI of the human brain with an analytical reception profile correction
    • Moyher SE, Vigneron DB, Nelson SJ. Surface coil MRI of the human brain with an analytical reception profile correction. JMRI 1995; 5:139-144.
    • (1995) JMRI , vol.5 , pp. 139-144
    • Moyher, S.E.1    Vigneron, D.B.2    Nelson, S.J.3
  • 18
  • 20
    • 0029147415 scopus 로고
    • Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain
    • Wald LL. Carvajal L, Moyher SE, et al. Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain. Magn Reson Med 1995; 34:433-439.
    • (1995) Magn Reson Med , vol.34 , pp. 433-439
    • Wald, L.L.1    Carvajal, L.2    Moyher, S.E.3
  • 23
    • 0029097336 scopus 로고
    • High contrast and fast three-dimensional magnetic resonance imaging at high fields
    • Lee JH, Garwood M, Menon R, et al. High contrast and fast three-dimensional magnetic resonance imaging at high fields. Magn Reson Med 1995; 34:308-312.
    • (1995) Magn Reson Med , vol.34 , pp. 308-312
    • Lee, J.H.1    Garwood, M.2    Menon, R.3
  • 24
    • 0000132799 scopus 로고
    • The sensitivity of zeumatographic experiments involving human samples
    • Hoult DI, Laterbur PC. The sensitivity of zeumatographic experiments involving human samples. J Magn Reson 1979; 34: 425-433.
    • (1979) J Magn Reson , vol.34 , pp. 425-433
    • Hoult, D.I.1    Laterbur, P.C.2
  • 25
    • 0027946439 scopus 로고
    • Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1 T
    • Hetherington HP, Mason GF, Pan JW, et al. Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1 T. Magn Reson Med 1994; 32:565-571.
    • (1994) Magn Reson Med , vol.32 , pp. 565-571
    • Hetherington, H.P.1    Mason, G.F.2    Pan, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.