메뉴 건너뛰기




Volumn 17, Issue 1, 1997, Pages 1-10

Predictions of serum vancomycin concentrations by means of six different equations for calculation of creatinine clearance

Author keywords

[No Author keywords available]

Indexed keywords

ANTIBIOTIC AGENT; VANCOMYCIN;

EID: 0031389824     PISSN: 02511649     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (26)
  • 2
    • 0016663065 scopus 로고
    • A new simple and rapid method to monitor the renal function based on pharmacokinetic consideration of endogenous creatinine
    • Chiou W.L., Hsu F.H. A new simple and rapid method to monitor the renal function based on pharmacokinetic consideration of endogenous creatinine. Res. Commun. Chem. Pathol. Pharmacol., 10, 315-330, 1975.
    • (1975) Res. Commun. Chem. Pathol. Pharmacol. , vol.10 , pp. 315-330
    • Chiou, W.L.1    Hsu, F.H.2
  • 3
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockroft D.W., Gault M.H. Prediction of creatinine clearance from serum creatinine. Nephron., 16, 31-41, 1976.
    • (1976) Nephron. , vol.16 , pp. 31-41
    • Cockroft, D.W.1    Gault, M.H.2
  • 4
    • 0015674428 scopus 로고
    • Creatinine clearance: Bedside estimate
    • Jelliffe R.W. Creatinine clearance: bedside estimate. Ann. Intern. Med., 79. 604-605, 1973.
    • (1973) Ann. Intern. Med. , vol.79 , pp. 604-605
    • Jelliffe, R.W.1
  • 5
    • 0002953816 scopus 로고
    • A computer program for estimation of creatinine clearance from unstable serum creatinine levels, age, sex, and weight
    • Jelliffe R.W., Jelliffe S.M. A computer program for estimation of creatinine clearance from unstable serum creatinine levels, age, sex, and weight Math Bosci. 14, 17-24, 1972
    • (1972) Math Bosci. , vol.14 , pp. 17-24
    • Jelliffe, R.W.1    Jelliffe, S.M.2
  • 7
    • 0027242239 scopus 로고
    • Computers in pharmacokinetics: Choosing software for clinical decision making
    • Buffington D.E., Lampasona V, Chandler M.H.H. Computers in pharmacokinetics: choosing software for clinical decision making. Clin. Pharmacokinet., 25, 205-216, 1993.
    • (1993) Clin. Pharmacokinet. , vol.25 , pp. 205-216
    • Buffington, D.E.1    Lampasona, V.2    Chandler, M.H.H.3
  • 8
    • 0141994218 scopus 로고
    • Computer applications in clinical pharmacokinetics and pharmacodynamics
    • Derendorf H., Hochhaus G., eds. CRC Press, London
    • Mungall D., Heissler J., Kaltenbach M. Computer applications in clinical pharmacokinetics and pharmacodynamics. In: Derendorf H., Hochhaus G., eds. "Handbook of pharmacokinetic/pharmacodynamic correlation." CRC Press, London, 1995, pp. 415-463.
    • (1995) Handbook of Pharmacokinetic/Pharmacodynamic Correlation , pp. 415-463
    • Mungall, D.1    Heissler, J.2    Kaltenbach, M.3
  • 9
    • 0024360243 scopus 로고
    • Individualizing vancomycin dosage regimens: One- Versus two-compartment Bayesian models
    • Pryka R.D., Rodvold K.A.. Garrison M, Rotschafer J.C. Individualizing vancomycin dosage regimens: one- versus two-compartment Bayesian models. Ther. Drug Monit., 11. 450-454, 1989.
    • (1989) Ther. Drug Monit. , vol.11 , pp. 450-454
    • Pryka, R.D.1    Rodvold, K.A.2    Garrison, M.3    Rotschafer, J.C.4
  • 10
    • 0024602458 scopus 로고
    • Evaluation of a two-compartment Bayesian forecasting program for predicting vancomycin concentrations
    • Rodvold K.A., Pryka R.D., Garrison M., Rotschafer J.C. Evaluation of a two-compartment Bayesian forecasting program for predicting vancomycin concentrations. Ther, Drug Monit., 11, 269-275 1989.
    • (1989) Ther. Drug Monit. , vol.11 , pp. 269-275
    • Rodvold, K.A.1    Pryka, R.D.2    Garrison, M.3    Rotschafer, J.C.4
  • 13
    • 0029003603 scopus 로고
    • Bayesian forecasting of serum vancomycin concentrations in neonates and infants
    • Rodvold K.A, et al. Bayesian forecasting of serum vancomycin concentrations in neonates and infants. Ther. Drug Monit., 17, 239-246, 1995.
    • (1995) Ther. Drug Monit. , vol.17 , pp. 239-246
    • Rodvold, K.A.1
  • 15
    • 0020551096 scopus 로고
    • Automated fluorescence polarization immunoassay for monitoring vancomycin
    • Schwenzer K.S., Warg C.H.J., Anhalt J.P. Automated fluorescence polarization immunoassay for monitoring vancomycin. Ther. Drug Monit., 5, 341-345, 1983.
    • (1983) Ther. Drug Monit. , vol.5 , pp. 341-345
    • Schwenzer, K.S.1    Warg, C.H.J.2    Anhalt, J.P.3
  • 16
    • 0029560595 scopus 로고
    • Calculating percentage prediction error: A user's note
    • Wu G., Baraldo M., Furlanut M. Calculating percentage prediction error: a user's note. Pharmacol. Res., 32, 241-248, 1995.
    • (1995) Pharmacol. Res. , vol.32 , pp. 241-248
    • Wu, G.1    Baraldo, M.2    Furlanut, M.3
  • 17
    • 0018398739 scopus 로고
    • Outliers in clinical chemistry quality-control schemes
    • Healy M.J.R. Outliers in clinical chemistry quality-control schemes. Clin. Chem., 25, 675-677. 1979.
    • (1979) Clin. Chem. , vol.25 , pp. 675-677
    • Healy, M.J.R.1
  • 18
    • 0019604592 scopus 로고
    • Some suggestions for measuring predictive performance
    • Sheiner L.B., Beal S.L. Some suggestions for measuring predictive performance. J. Pharmacokinet. Biopharm., 9, 503-512, 1981
    • (1981) J. Pharmacokinet. Biopharm. , vol.9 , pp. 503-512
    • Sheiner, L.B.1    Beal, S.L.2
  • 19
    • 0029049236 scopus 로고
    • Calculating predictive performance: A user's note
    • Wu G. Calculating predictive performance: a user's note. Pharmacol. Res., 31. 393-399, 1995.
    • (1995) Pharmacol. Res. , vol.31 , pp. 393-399
    • Wu, G.1
  • 20
    • 0018857352 scopus 로고
    • Clinical estimation of creatinine clearance without urine collection
    • Parker R.A., Bennett W.M., Porter G.A. Clinical estimation of creatinine clearance without urine collection. Dial. Transplant., 9, 251-252, 1980.
    • (1980) Dial. Transplant. , vol.9 , pp. 251-252
    • Parker, R.A.1    Bennett, W.M.2    Porter, G.A.3
  • 23
    • 0021966658 scopus 로고
    • Creatinine clearance estimation from serum creatinine values: An analysis of three mathematical models of glomerular function
    • Gates G.F. Creatinine clearance estimation from serum creatinine values: an analysis of three mathematical models of glomerular function Am. J. Kidney Dis., 5, 199-205, 1985.
    • (1985) Am. J. Kidney Dis. , vol.5 , pp. 199-205
    • Gates, G.F.1
  • 25
    • 0026442320 scopus 로고
    • Serum creatinine as an index of renal function new insights into old concepts
    • Perrone R.D., Madias N.E., Levey A.S. Serum creatinine as an index of renal function new insights into old concepts. Clin. Chem., 38, 1933-1953, 1992.
    • (1992) Clin. Chem. , vol.38 , pp. 1933-1953
    • Perrone, R.D.1    Madias, N.E.2    Levey, A.S.3
  • 26
    • 0030428916 scopus 로고    scopus 로고
    • Prediction of blood cyclosporine concentrations in haematological patients with multidrug resistance by means of total, lean and different adipose dosing body weight using Bayesian and non-linear least squares methods
    • Wu G., Furlanut M. Prediction of blood cyclosporine concentrations in haematological patients with multidrug resistance by means of total, lean and different adipose dosing body weight using Bayesian and non-linear least squares methods. Int. J. Clin. Pharm. Res., XVI, 4/5, 89-97, 1996.
    • (1996) Int. J. Clin. Pharm. Res. , vol.16 , Issue.4-5 , pp. 89-97
    • Wu, G.1    Furlanut, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.