메뉴 건너뛰기




Volumn 37, Issue , 1997, Pages 357-363

Effects of evaporator frosting on the performance of an air-to-air heat pump

Author keywords

[No Author keywords available]

Indexed keywords

DEFROSTING; EVAPORATORS; FROST EFFECTS; HEAT TRANSFER; MATHEMATICAL MODELS;

EID: 0031387117     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Article
Times cited : (2)

References (24)
  • 4
    • 0001393871 scopus 로고
    • Heat, Mass and Momentum Transfer Inside Frosted Tubes - Experiment and Theory
    • Chen, M.M., and Rohsenow, W., 1964, "Heat, Mass and Momentum Transfer Inside Frosted Tubes - Experiment and Theory," Journal of Heat Transfer, Transactions ASME, Vol. 86, pp. 334-340.
    • (1964) Journal of Heat Transfer, Transactions ASME , vol.86 , pp. 334-340
    • Chen, M.M.1    Rohsenow, W.2
  • 8
    • 0000077177 scopus 로고
    • The Effects of Frost Growth on Extended Surface Heat Exchanger Performance: A Review
    • Kondepudi, S. N., and O'Neal, D.L., 1987, "The Effects of Frost Growth on Extended Surface Heat Exchanger Performance: A Review," ASHRAE Transactions, Vol. 93, Part 2, pp. 258-274.
    • (1987) ASHRAE Transactions , vol.93 , Issue.2 PART , pp. 258-274
    • Kondepudi, S.N.1    O'Neal, D.L.2
  • 9
    • 0001244690 scopus 로고
    • Prediction of Cyclic Heat Pump Performance with a Fully-Distributed Model and a Comparison with Experimental Data
    • MacArthur, J.W., and Grald, E.W., "Prediction of Cyclic Heat Pump Performance with a Fully-Distributed Model and a Comparison with Experimental Data," ASHRAE Transactions, Vol. 93, Part 2, 1987.
    • (1987) ASHRAE Transactions , vol.93 , Issue.2 PART
    • MacArthur, J.W.1    Grald, E.W.2
  • 10
    • 0006389420 scopus 로고
    • Heat and Mass Transfer under Frosting Conditions
    • Marinyuk, B. T., 1980, "Heat and Mass Transfer Under Frosting Conditions," International Journal of Refrigeration, Vol. 3, No. 6, pp. 366-368.
    • (1980) International Journal of Refrigeration , vol.3 , Issue.6 , pp. 366-368
    • Marinyuk, B.T.1
  • 13
    • 0001672409 scopus 로고
    • Measurement of Frost Growth and Density in a Parallel Plate Geometry
    • O'Neal, D. L., and Tree, D.R., 1984, "Measurement of Frost Growth and Density in a Parallel Plate Geometry," ASHRAE Transactions, Vol. 90, Part 2, pp. 278-290.
    • (1984) ASHRAE Transactions , vol.90 , Issue.2 PART , pp. 278-290
    • O'Neal, D.L.1    Tree, D.R.2
  • 14
    • 0000954674 scopus 로고
    • A Review of Frost Formation in Simple Geometries
    • O'Neal, D.L., and Tree, D.R., 1985, "A Review of Frost Formation in Simple Geometries," ASHRAE Transactions, Vol. 91, Part 2, pp. 267-281.
    • (1985) ASHRAE Transactions , vol.91 , Issue.2 PART , pp. 267-281
    • O'Neal, D.L.1    Tree, D.R.2
  • 15
    • 0029250487 scopus 로고
    • Defrost Cycle Performance for an Air-Source Heat Pump with a Scroll and a Reciprocating Compressor
    • Payne, V. and O'Neal, D.L., 1995, "Defrost Cycle Performance for an Air-Source Heat Pump with a Scroll and a Reciprocating Compressor," International Journal of Refrigeration, Vol. 18, pp. 107-112.
    • (1995) International Journal of Refrigeration , vol.18 , pp. 107-112
    • Payne, V.1    O'Neal, D.L.2
  • 20
    • 0002816289 scopus 로고
    • How Frost formation on Coils Affects Refrigeration Systems
    • Stoecker, W.F., 1957, "How Frost formation on Coils Affects Refrigeration Systems," Refrigerating Engineer, Vol. 65, No. 2, pp. 42-46.
    • (1957) Refrigerating Engineer , vol.65 , Issue.2 , pp. 42-46
    • Stoecker, W.F.1
  • 21
    • 0022935345 scopus 로고
    • Air to Air Heat Pumps Operating under Frosting Conditions on the Outdoor Coil
    • Tantakitti, C., and Howell, R:H:,1986, "Air to Air Heat Pumps Operating Under Frosting Conditions on the Outdoor Coil," ASHRAE Transactions, Vol. 92, Part 1B, pp. 827-842.
    • (1986) ASHRAE Transactions , vol.92 , Issue.PART 1B , pp. 827-842
    • Tantakitti, C.1    Howell, R.H.2
  • 22
    • 0012437965 scopus 로고
    • Frost Growth Characteristics on Heat Exchanger Surfaces: Measurement and Simulation Studies
    • ASME
    • Tao, Y.X., Mao, and Besant, R.W., 1994, "Frost Growth Characteristics on Heat Exchanger Surfaces: Measurement and Simulation Studies," ASME HTD-Vol. 288, "Fundamentals of Phase Change: Sublimation and Solidification," pp. 29-38.
    • (1994) Fundamentals of Phase Change: Sublimation and Solidification , vol.288 HTD , pp. 29-38
    • Tao, Y.X.1    Mao2    Besant, R.W.3
  • 23
    • 0023209429 scopus 로고
    • Effects of Evaporator Frosting and Defrosting on the Performance of Air-to Water Heat Pumps
    • Tassou, S.A., and Marquand, C.J., 1987, "Effects of Evaporator Frosting and Defrosting on the Performance of Air-to Water Heat Pumps,". Applied Energy, Vol. 28, No. 1, pp. 19-33.
    • (1987) Applied Energy , vol.28 , Issue.1 , pp. 19-33
    • Tassou, S.A.1    Marquand, C.J.2
  • 24
    • 0001948288 scopus 로고
    • An Investigation of the Thermal Conductivity of Frost while Forming on a Flat Horizontal Plate
    • Yonko, J.D., and Sepsy, C.F., 1967, "An Investigation of the Thermal Conductivity of Frost while Forming on a Flat Horizontal Plate", ASHRAE Transactions, Vol. 73, Part 1.
    • (1967) ASHRAE Transactions , vol.73 , Issue.1 PART
    • Yonko, J.D.1    Sepsy, C.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.