메뉴 건너뛰기




Volumn 28, Issue 1-6, 1997, Pages 823-830

A CR-39 track image analyser for neutron spectrometry

Author keywords

CCD optical scanners; Monte Carlo unfolding codes; Neutron spectrometry; Track analysis

Indexed keywords

ARRAYS; CHARGE COUPLED DEVICES; COMPUTER SOFTWARE; IMAGE ANALYSIS; MONTE CARLO METHODS; NEUTRON SPECTROMETERS; PARTICLE BEAM TRACKING; POLYCARBONATES; SCANNING;

EID: 0031367768     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(97)00191-1     Document Type: Article
Times cited : (23)

References (10)
  • 1
    • 50849147048 scopus 로고
    • The track-etch detector of the MACRO experiment
    • Calicchio M. et al. (1988) The track-etch detector of the MACRO experiment. Nucl. Tracks Radiat. Meas. 15(1-4), 331-336.
    • (1988) Nucl. Tracks Radiat. Meas. , vol.15 , Issue.1-4 , pp. 331-336
    • Calicchio, M.1
  • 2
    • 0026472114 scopus 로고
    • Experimental assembly for the simulation of realistic neutron spectra
    • Chartier J.L., Posny F. and Buxerolle M. (1992) Experimental assembly for the simulation of realistic neutron spectra. Radiat. Prot. Dosim. 44, 125-130.
    • (1992) Radiat. Prot. Dosim. , vol.44 , pp. 125-130
    • Chartier, J.L.1    Posny, F.2    Buxerolle, M.3
  • 3
    • 0000899868 scopus 로고
    • PTB neutron fields for the calibration of neutron sensitive devices
    • eds. W. Kölzer and R. Maushart, Köln: Verlag TÜV
    • Guldbakke S., Dietz E., Kluge H. and Schlegel D. (1994) PTB neutron fields for the calibration of neutron sensitive devices. In: Strahlenschutz: Physik und Messtechnik; eds. W. Kölzer and R. Maushart, pp. 240-247 (Köln: Verlag TÜV).
    • (1994) Strahlenschutz: Physik und Messtechnik , pp. 240-247
    • Guldbakke, S.1    Dietz, E.2    Kluge, H.3    Schlegel, D.4
  • 4
    • 0031343931 scopus 로고    scopus 로고
    • Neutron spectrometry with CR-39 track detectors and silicon diodes using unfolding techniques
    • this issue
    • Luszik-Bhadra M., Dietz E., d'Errico F., Guldbakke S. and Matzke M. (1997) Neutron spectrometry with CR-39 track detectors and silicon diodes using unfolding techniques. Radiat. Meas. (this issue).
    • (1997) Radiat. Meas.
    • Luszik-Bhadra, M.1    Dietz, E.2    D'Errico, F.3    Guldbakke, S.4    Matzke, M.5
  • 5
    • 0010656177 scopus 로고    scopus 로고
    • Microdosimetric investigations in a proton therapy beam with sequentially etched CR-39 track detectors
    • Luszik-Bhadra M., d'Errico F., Lusini L. and Wiegel B. (1996) Microdosimetric investigations in a proton therapy beam with sequentially etched CR-39 track detectors. Radiat. Prot. Dosim. 66, 353-358.
    • (1996) Radiat. Prot. Dosim. , vol.66 , pp. 353-358
    • Luszik-Bhadra, M.1    D'Errico, F.2    Lusini, L.3    Wiegel, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.