메뉴 건너뛰기




Volumn 20, Issue 9, 1997, Pages 680-688

Post penetrating keratoplasty astigmatism. A videokeratoscopic analysis;Astigmatisme apres keratoplastie transfixiante. Analyse video- keratoscopique sur une serie de 60 greffes

Author keywords

Astigmatism; Penetrating keratoplasty; Videokeratoscopy

Indexed keywords

ARTICLE; ASTIGMATISM; DIAGNOSTIC VALUE; FEMALE; HUMAN; KERATOPLASTY; KERATOSCOPY; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; VIDEORECORDING; ADOLESCENT; ADULT; AGED; ALGORITHM; CHILD; EVALUATION; MIDDLE AGED; OPHTHALMOSCOPY; PENETRATING KERATOPLASTY; RETROSPECTIVE STUDY; VISUAL ACUITY;

EID: 0031313868     PISSN: 01815512     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (18)
  • 1
  • 2
    • 0018776295 scopus 로고
    • Astigmatism considerations in corneal grafting
    • TROUTMAN R.C. - Astigmatism considerations in corneal grafting. Ophthalmic Surg, 1979; 10:21-26.
    • (1979) Ophthalmic Surg , vol.10 , pp. 21-26
    • Troutman, R.C.1
  • 3
    • 0019523528 scopus 로고
    • An analysis and interpretation of refractive errors after penetrating keratoplasty
    • PERLMAN E.M. - An analysis and interpretation of refractive errors after penetrating keratoplasty. Ophthalmology, 1981; 88:39-45.
    • (1981) Ophthalmology , vol.88 , pp. 39-45
    • Perlman, E.M.1
  • 4
    • 0018900546 scopus 로고
    • Surgical advances and results of keratoconus
    • TROUTMAN R.C., GASTER R.N. - Surgical advances and results of keratoconus. Ophthalmic Surg, 1980; 90:131-136.
    • (1980) Ophthalmic Surg , vol.90 , pp. 131-136
    • Troutman, R.C.1    Gaster, R.N.2
  • 5
    • 0018307212 scopus 로고
    • Refracting variation and donnor tissue size in aphatic keratoplasty
    • OLSON R.J., MATTINGLY T.P., WATTMAN S.R., KAUFMAN H.E. - Refracting variation and donnor tissue size in aphatic keratoplasty. Arch Ophthalmol, 1979; 97:1323-1325.
    • (1979) Arch Ophthalmol , vol.97 , pp. 1323-1325
    • Olson, R.J.1    Mattingly, T.P.2    Wattman, S.R.3    Kaufman, H.E.4
  • 6
    • 0020197534 scopus 로고
    • Astigmatism after keratoplasty : Possible cause and method of prevention
    • KAUFMAN H.E. - Astigmatism after keratoplasty : possible cause and method of prevention. Am J Ophthalmol, 1982; 94:556-557.
    • (1982) Am J Ophthalmol , vol.94 , pp. 556-557
    • Kaufman, H.E.1
  • 7
    • 0023934053 scopus 로고
    • The effect of the suture removal on post keratoplasty astigmatism
    • BINDER P.S. - The effect of the suture removal on post keratoplasty astigmatism. Am J Ophthalmol, 1988; 105:637-645.
    • (1988) Am J Ophthalmol , vol.105 , pp. 637-645
    • Binder, P.S.1
  • 8
    • 0028845812 scopus 로고
    • Kératoplastie transfixiante après conservation du greffon en organo-culture à31 °C, resultats à 1 an
    • BORDERIE V., LAROCHE L., VEDIE F., LOPEZ M. - Kératoplastie transfixiante après conservation du greffon en organo-culture à31 °C, resultats à 1 an. J Fr Ophthalmol, 1995; 18:570-577.
    • (1995) J Fr Ophthalmol , vol.18 , pp. 570-577
    • Borderie, V.1    Laroche, L.2    Vedie, F.3    Lopez, M.4
  • 10
    • 0027317877 scopus 로고
    • When keratometric measurements do not accurately reflect corneal topography
    • SANDERS D.R., GILLS J.P., MARTIN R.G. - When keratometric measurements do not accurately reflect corneal topography. J Cataract Refract Surg, 1993; 19:131-135.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 131-135
    • Sanders, D.R.1    Gills, J.P.2    Martin, R.G.3
  • 11
    • 0024604296 scopus 로고
    • The topography of the normal corneas
    • DINGELDEIN S.A., KLYCE S.D. - The topography of the normal corneas. Arch Ophthalmol, 1989; 107:512-518.
    • (1989) Arch Ophthalmol , vol.107 , pp. 512-518
    • Dingeldein, S.A.1    Klyce, S.D.2
  • 12
    • 0029156047 scopus 로고
    • Shape and refractive powers in corneal topography
    • KLEIN S.A., MANDELL R.B. - Shape and refractive powers in corneal topography. Invest Ophthalmol Vis Sci, 1995; 36:2096-2109.
    • (1995) Invest Ophthalmol Vis Sci , vol.36 , pp. 2096-2109
    • Klein, S.A.1    Mandell, R.B.2
  • 13
    • 0030946483 scopus 로고    scopus 로고
    • Corneal topography using the Holladay Diagnostic Summary
    • HOLLADAY J.T. - Corneal topography using the Holladay Diagnostic Summary. J Cataract Refract Surg, 1997; 23:209-221.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 209-221
    • Holladay, J.T.1
  • 14
    • 0025322759 scopus 로고
    • Classification of normal corneal topography based on computer-assisted videokeratography
    • BOGAN S.J., WARING III G.O., IBRAHIM O., DREWS C., CURTIS L. - Classification of normal corneal topography based on computer-assisted videokeratography. Arch Ophthalmol, 1990; 108: 945-949.
    • (1990) Arch Ophthalmol , vol.108 , pp. 945-949
    • Bogan, S.J.1    Waring III, G.O.2    Ibrahim, O.3    Drews, C.4    Curtis, L.5
  • 15
    • 0019156615 scopus 로고
    • Corneal curvature changes associated with penetrating keratoplasty : A mathematical model
    • OLSON R.J. - Corneal curvature changes associated with penetrating keratoplasty : a mathematical model. Ophthalmic Surg, 1980; 12:838-842.
    • (1980) Ophthalmic Surg , vol.12 , pp. 838-842
    • Olson, R.J.1
  • 16
    • 18744437996 scopus 로고
    • Astigmatisme et kératoplastie
    • LAROCHE L. - Astigmatisme et kératoplastie. Bull Soc Oph France, 1987; LXXXVII:1461-1465.
    • (1987) Bull Soc Oph France , vol.87 , pp. 1461-1465
    • Laroche, L.1
  • 18
    • 0029843728 scopus 로고    scopus 로고
    • Measurement of irregular astigmatism using semi meridian data from videokeratographs
    • BORDERIE V., LAROCHE L. - Measurement of irregular astigmatism using semi meridian data from videokeratographs. J Refract Surg, 1996; 12: 595-600.
    • (1996) J Refract Surg , vol.12 , pp. 595-600
    • Borderie, V.1    Laroche, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.