메뉴 건너뛰기




Volumn 78, Issue 12, 1997, Pages 1245-1253

Target volume determination for stereotactic radiosurgery treatment planning;Determination de volumes cibles pour la planification dosimetrique en radiochirurgie stereotaxique

Author keywords

Images, analysis; Stereotaxis; Therapeutic radiology, computer assisted; Treatment planning

Indexed keywords

ACOUSTIC NEURINOMA; ARTICLE; CENTRAL NERVOUS SYSTEM TUMOR; COMPUTER ASSISTED TOMOGRAPHY; DIGITAL SUBTRACTION ANGIOGRAPHY; HUMAN; IMAGE ANALYSIS; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; RADIOSURGERY; STEREOTAXIC SURGERY; TREATMENT PLANNING; COMPUTER ASSISTED RADIOTHERAPY; INSTRUMENTATION; METHODOLOGY; RADIATION DOSE;

EID: 0031304312     PISSN: 02210363     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (23)
  • 1
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W, Winston KR, Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 1988;14 (2):373-81.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , Issue.2 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 3
    • 0020506214 scopus 로고
    • Stereotactic radiosurgery
    • Leksell L. Stereotactic radiosurgery. J Neurol Neurosurg Psychiatry 1983;46 (9):797-803.
    • (1983) J Neurol Neurosurg Psychiatry , vol.46 , Issue.9 , pp. 797-803
    • Leksell, L.1
  • 4
    • 0027471614 scopus 로고
    • Stereotactic radiosurgery: Principles and comparison of treatment methods
    • Luxton G, Petrovich Z, Jozsef G, Nedzi LA, Apuzzo ML. Stereotactic radiosurgery: principles and comparison of treatment methods. Neurosurgery 1993;32 (2):241-59.
    • (1993) Neurosurgery , vol.32 , Issue.2 , pp. 241-259
    • Luxton, G.1    Petrovich, Z.2    Jozsef, G.3    Nedzi, L.A.4    Apuzzo, M.L.5
  • 5
    • 0016075405 scopus 로고
    • New approach to the neurosurgery of epilepsy. Stereotaxic methodology and therapeutic results. 1. Introduction and history
    • Talairach J, Bancaud J, Szikla G, Bonis A, Geier S, Vedrenne C. New approach to the neurosurgery of epilepsy. Stereotaxic methodology and therapeutic results. 1. Introduction and history. Neurochirurgie 1974;20 (1):1-240.
    • (1974) Neurochirurgie , vol.20 , Issue.1 , pp. 1-240
    • Talairach, J.1    Bancaud, J.2    Szikla, G.3    Bonis, A.4    Geier, S.5    Vedrenne, C.6
  • 6
    • 0021646662 scopus 로고
    • Stereotaxic device for polar approaches in orthogonal systems
    • Scerrati M, Fiorentino A, Fiorentino M, Pola P. Stereotaxic device for polar approaches in orthogonal systems. J Neurosurg 1984;61 (6):1146-7.
    • (1984) J Neurosurg , vol.61 , Issue.6 , pp. 1146-1147
    • Scerrati, M.1    Fiorentino, A.2    Fiorentino, M.3    Pola, P.4
  • 7
    • 0020652489 scopus 로고
    • Mulliple-beam stereotaxic irradiation
    • Betti O, Derechinsky V. Mulliple-beam stereotaxic irradiation. Neurochirurgie 1983;29 (4):295-8.
    • (1983) Neurochirurgie , vol.29 , Issue.4 , pp. 295-298
    • Betti, O.1    Derechinsky, V.2
  • 8
    • 0023005557 scopus 로고
    • Integrated stereotaxic imaging with CT, MR imaging and Digital Subtraction Angiography
    • Peters TM, Clarck JA et al. Integrated stereotaxic imaging with CT, MR imaging and Digital Subtraction Angiography. Radiology 1986;161:821-26.
    • (1986) Radiology , vol.161 , pp. 821-826
    • Peters, T.M.1    Clarck, J.A.2
  • 12
    • 0031053552 scopus 로고    scopus 로고
    • Assessment of image intensifier and distortion for DSA localisation studies
    • Coste E, Gibon D, Rousseau J. Assessment of image intensifier and distortion for DSA localisation studies. Brit J Radiol 1997;70:70-3.
    • (1997) Brit J Radiol , vol.70 , pp. 70-73
    • Coste, E.1    Gibon, D.2    Rousseau, J.3
  • 15
    • 0029154373 scopus 로고
    • Treatment planning optimization by conjugate gradients and simulated annealing methods in stereotactic radiosurgery
    • Gibon D, Rousseau J, Castelain B, Blond S, Vasseur C, Marchandise X. Treatment planning optimization by conjugate gradients and simulated annealing methods in stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 1995;33 (1):201-10.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , Issue.1 , pp. 201-210
    • Gibon, D.1    Rousseau, J.2    Castelain, B.3    Blond, S.4    Vasseur, C.5    Marchandise, X.6
  • 16
    • 0020053781 scopus 로고
    • Volume determinations using computed tomography
    • Breiman RS, Beck JW, Korobkin M et al. Volume determinations using computed tomography. Am J Roentgenol 1982;138:329-33.
    • (1982) Am J Roentgenol , vol.138 , pp. 329-333
    • Breiman, R.S.1    Beck, J.W.2    Korobkin, M.3
  • 17
    • 0025732746 scopus 로고
    • Stereotaxic angiography: An inadequate database for radiosurgery ?
    • Bova FJ, Friedman WA. Stereotaxic angiography: an inadequate database for radiosurgery ? Int J Radiat Oncol Biol Phys 1991;20:891-5.
    • (1991) Int J Radiat Oncol Biol Phys , vol.20 , pp. 891-895
    • Bova, F.J.1    Friedman, W.A.2
  • 19
    • 0023395668 scopus 로고
    • Stereotaxic localisation of intracranial targets
    • Siddon RL, Barth NH. Stereotaxic localisation of intracranial targets. Int J Radiat Oncol Biol Phys 1987;13:1241-6.
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , pp. 1241-1246
    • Siddon, R.L.1    Barth, N.H.2
  • 21
    • 0015082956 scopus 로고
    • Continuous shading of curved surfaces
    • Gouraud H. Continuous shading of curved surfaces. IEEE Trans on Computers 1971;20 (6):623-9.
    • (1971) IEEE Trans on Computers , vol.20 , Issue.6 , pp. 623-629
    • Gouraud, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.