메뉴 건너뛰기




Volumn 7, Issue 4, 1997, Pages 277-284

Locking strength of Morse tapers used for modular segmental bone defect replacement prostheses

Author keywords

Bone defect; Joint strength; Mechanical testing; Segmental prosthesis; Taper lock

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; HUMAN; MATERIALS TESTING; PROSTHESIS; PROSTHESIS FAILURE; STANDARD;

EID: 0031303825     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/bme-1997-7407     Document Type: Article
Times cited : (14)

References (10)
  • 3
    • 0342377838 scopus 로고
    • Tumor prosthesis design
    • E.Y. Chao and J.C. Ivins, eds, Thieme-Stratton, New York
    • E.Y. Chao and F.H. Sim, Tumor prosthesis design, in: Tumor Prostheses for Bone and Joint Reconstruction, E.Y. Chao and J.C. Ivins, eds, Thieme-Stratton, New York, 1983, pp. 335-360.
    • (1983) Tumor Prostheses for Bone and Joint Reconstruction , pp. 335-360
    • Chao, E.Y.1    Sim, F.H.2
  • 4
    • 0024364184 scopus 로고
    • A composite fixation principle for modular segmental defect replacement (SDR) prostheses
    • E.Y. Chao and F.H. Sim, A composite fixation principle for modular segmental defect replacement (SDR) prostheses, Orthop. Clin. North Am. 20(3) (1989), 439-453.
    • (1989) Orthop. Clin. North Am. , vol.20 , Issue.3 , pp. 439-453
    • Chao, E.Y.1    Sim, F.H.2
  • 6
    • 5544310743 scopus 로고
    • Mechanical strength and critical stress distribution of Morse taper lock in modular segmental prosthesis design
    • G.E. Frielander, ed Washington
    • E.Y. Chao, J.K. Suh and J. Grabowski, Mechanical strength and critical stress distribution of Morse taper lock in modular segmental prosthesis design, in: Transactions of the 38th Annual Meeting of the Orthopaedic Research Society, G.E. Frielander, ed., Vol. 17, Washington, 1992, p. 310.
    • (1992) Transactions of the 38th Annual Meeting of the Orthopaedic Research Society , vol.17 , pp. 310
    • Chao, E.Y.1    Suh, J.K.2    Grabowski, J.3
  • 8
    • 0024886171 scopus 로고
    • Friction in femoral prosthesis and photoelastic model cone taper joints
    • H. Fessler and D.C. Flicker, Friction in femoral prosthesis and photoelastic model cone taper joints, J. Eng. Med. 203 (1989), 1-14.
    • (1989) J. Eng. Med. , vol.203 , pp. 1-14
    • Fessler, H.1    Flicker, D.C.2
  • 9
    • 0024917291 scopus 로고
    • A study of stresses in alumina universal heads of femoral prosthesis
    • H. Fessler and D.C. Fricker, A study of stresses in alumina universal heads of femoral prosthesis, J. Eng. Med. 203 (1989), 15-34.
    • (1989) J. Eng. Med. , vol.203 , pp. 15-34
    • Fessler, H.1    Fricker, D.C.2
  • 10
    • 0030111101 scopus 로고    scopus 로고
    • Effect of manufacturing tolerances on the micromotion at the Morse taper interface in modular hip implants using the finite element technique
    • N.H. Shareef and D.L. Levine, Effect of manufacturing tolerances on the micromotion at the Morse taper interface in modular hip implants using the finite element technique, Biomaterials 17 (1996), 623-630.
    • (1996) Biomaterials , vol.17 , pp. 623-630
    • Shareef, N.H.1    Levine, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.