메뉴 건너뛰기




Volumn 5, Issue 4, 1997, Pages 251-257

Tibial component positioning in total knee arthroplasty: Bone coverage and extensor apparatus alignment

Author keywords

Bone coverage; Patello femoral tracking; Total knee arthroplasty

Indexed keywords

AGED; ARTICLE; FEMALE; HUMAN; KNEE ARTHROPLASTY; KNEE PROSTHESIS; MALE; METHODOLOGY; MIDDLE AGED; PROSTHESIS;

EID: 0031298204     PISSN: 09422056     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001670050059     Document Type: Article
Times cited : (47)

References (24)
  • 1
  • 2
    • 0025836897 scopus 로고
    • Current principles of design for cemented or cementless knees prosthesis
    • Bindelglass DF, Cohen JL, Dorr LD (1991) Current principles of design for cemented or cementless knees prosthesis. Tech Orthop 6: 80
    • (1991) Tech Orthop , vol.6 , pp. 80
    • Bindelglass, D.F.1    Cohen, J.L.2    Dorr, L.D.3
  • 4
    • 0028566576 scopus 로고
    • Tibial component wear in total knee replacement
    • Cameron HU (1994) Tibial component wear in total knee replacement. Clin Orthop 309: 29-32
    • (1994) Clin Orthop , vol.309 , pp. 29-32
    • Cameron, H.U.1
  • 5
    • 0027752702 scopus 로고
    • Non cemented porous in growth knee prosthesis: The 3 to 8 year results
    • Cameron HU, Jung YB (1993) Non cemented porous in growth knee prosthesis: the 3 to 8 year results. Can J Surg 36: 560-566
    • (1993) Can J Surg , vol.36 , pp. 560-566
    • Cameron, H.U.1    Jung, Y.B.2
  • 6
    • 3142529961 scopus 로고    scopus 로고
    • (Encyclopédie médico-chirurgicale, techniques chirurgicales - orthopedie - traumatologie, 44-850). Elsevier, Paris
    • Dejour H, Dejour D (1996) Technique d'implantation des prothèses de genou (Encyclopédie médico-chirurgicale, techniques chirurgicales - orthopedie - traumatologie, 44-850). Elsevier, Paris
    • (1996) Technique d'Implantation des Prothèses de Genou
    • Dejour, H.1    Dejour, D.2
  • 7
    • 0028294591 scopus 로고
    • Three-dimensionnal computed tomography reconstruction of tibial torsion
    • Eckhoff DG, Johnson KK (1994) Three-dimensionnal computed tomography reconstruction of tibial torsion. Clin Orthop 302: 42-46
    • (1994) Clin Orthop , vol.302 , pp. 42-46
    • Eckhoff, D.G.1    Johnson, K.K.2
  • 8
    • 0028787955 scopus 로고    scopus 로고
    • Malrotation associated with implant alignment technique in total knee arthroplasty
    • Eckhoff DG, Metzger RG, Vandewalle MV (1996) Malrotation associated with implant alignment technique in total knee arthroplasty. Clin Orthop 321: 28-31
    • (1996) Clin Orthop , vol.321 , pp. 28-31
    • Eckhoff, D.G.1    Metzger, R.G.2    Vandewalle, M.V.3
  • 10
    • 0021078583 scopus 로고
    • The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
    • Goldstein SA, Wilson DL, Sonstegart DA, Matthews LS (1983) The mechanical properties of human tibial trabecular bone as a function of metaphyseal location. J Biomech 16: 965-969
    • (1983) J Biomech , vol.16 , pp. 965-969
    • Goldstein, S.A.1    Wilson, D.L.2    Sonstegart, D.A.3    Matthews, L.S.4
  • 11
    • 0021350143 scopus 로고
    • Cancellous bone strength at the proximal human tibia
    • Hvid I, Jensen J (1984) Cancellous bone strength at the proximal human tibia. Eng Med 13: 21-25
    • (1984) Eng Med , vol.13 , pp. 21-25
    • Hvid, I.1    Jensen, J.2
  • 14
    • 0018875867 scopus 로고
    • Tibial torsion calculated by computerised tomography and compared to other methods of measurements
    • Br
    • Jakob RP, Haertel M, Stussi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurements. J Bone Joint Surg [Br] 62: 238-242
    • (1980) J Bone Joint Surg , vol.62 , pp. 238-242
    • Jakob, R.P.1    Haertel, M.2    Stussi, E.3
  • 15
    • 3142576427 scopus 로고
    • An evaluation of the load bearing capability of the proximal tibia with special interest in the design of knee implants
    • Johnson JA, Krug WH, Nahon D, Miller JE, Ahmed AM (1983) An evaluation of the load bearing capability of the proximal tibia with special interest in the design of knee implants. Trans Orthop Res Soc 8: 403
    • (1983) Trans Orthop Res Soc , vol.8 , pp. 403
    • Johnson, J.A.1    Krug, W.H.2    Nahon, D.3    Miller, J.E.4    Ahmed, A.M.5
  • 17
    • 0004637766 scopus 로고
    • Les anomalies de rotation des membres inférieurs
    • Lerat JL, Taussig G (1982) Les anomalies de rotation des membres inférieurs. Rev Chir Orthop 68: 1-74
    • (1982) Rev Chir Orthop , vol.68 , pp. 1-74
    • Lerat, J.L.1    Taussig, G.2
  • 18
    • 0028008566 scopus 로고
    • Postera- medial polyethylene failure in total knee replacements
    • Lewis P, Rorabeck CH, Bourne RB, Devane P (1994) Postera- medial polyethylene failure in total knee replacements. Clin Orthop 299: 11-17
    • (1994) Clin Orthop , vol.299 , pp. 11-17
    • Lewis, P.1    Rorabeck, C.H.2    Bourne, R.B.3    Devane, P.4
  • 19
    • 0017353885 scopus 로고
    • Influence of positioning of prosthesis in total knee replacement
    • Am
    • Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59: 77-79
    • (1977) J Bone Joint Surg , vol.59 , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 20
    • 0015990421 scopus 로고
    • Quantitative studies of human subchondral cancellous bone. Its relationship to the state of its overlying cartilage
    • Am
    • Pugh JW, Radin EL, Rose RM (1974) Quantitative studies of human subchondral cancellous bone. Its relationship to the state of its overlying cartilage. J Bone Joint Surg [Am] 56: 313-321
    • (1974) J Bone Joint Surg , vol.56 , pp. 313-321
    • Pugh, J.W.1    Radin, E.L.2    Rose, R.M.3
  • 21
    • 0007260810 scopus 로고
    • Posterior sacrificing and preserving total knee arthroplasty
    • Rand J (ed). Raven Press, New York
    • Rosenberg A (1993) Posterior sacrificing and preserving total knee arthroplasty. In: Rand J (ed) Total knee arthroplasty. Raven Press, New York, pp 115-153
    • (1993) Total Knee Arthroplasty , pp. 115-153
    • Rosenberg, A.1
  • 23
    • 0027972449 scopus 로고
    • Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical consideration during total knee arthroplasty
    • Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical consideration during total knee arthroplasty. Clin Orthop 299: 31-43
    • (1994) Clin Orthop , vol.299 , pp. 31-43
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.M.3    Natarajan, R.N.4    Rosenberg, A.G.5
  • 24
    • 0028577921 scopus 로고
    • Resection specimen analysis of tibial coverage in total knee arthroplasty
    • Westrich GH, Laskin RS, Haas SB, Sculco TP (1994) Resection specimen analysis of tibial coverage in total knee arthroplasty. Clin Orthop 309: 163-175
    • (1994) Clin Orthop , vol.309 , pp. 163-175
    • Westrich, G.H.1    Laskin, R.S.2    Haas, S.B.3    Sculco, T.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.