메뉴 건너뛰기




Volumn 23, Issue 6, 1997, Pages 751-762

Investigation of contact vacuuming for remediation of fungally contaminated duct materials

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING DUCTS; AIR QUALITY; ATMOSPHERIC HUMIDITY; CLEANING; CONTAMINATION; FUNGUS ATTACK; VACUUM APPLICATIONS; VENTILATION DUCTS;

EID: 0031282644     PISSN: 01604120     EISSN: 18736750     Source Type: Journal    
DOI: 10.1016/S0160-4120(97)00087-1     Document Type: Article
Times cited : (9)

References (15)
  • 1
    • 85022109644 scopus 로고
    • Air distribution design for small heating and cooling systems
    • Atlanta, GA: American Society for Heating, Refrigeration and Air Conditioning Engineers
    • ASHRAE. Air distribution design for small heating and cooling systems. HVAC systems and equipment. Atlanta, GA: American Society for Heating, Refrigeration and Air Conditioning Engineers; 1992: 9.4-9.5.
    • (1992) HVAC Systems and Equipment , pp. 94-95
  • 2
    • 0029934254 scopus 로고    scopus 로고
    • Assessment of fungal (Penicillium chrysogenum) growth on three HVAC Duct materials
    • Chang, J.C.S.; Foarde, K.K.; VanOsdell, D.W. Assessment of Fungal (Penicillium chrysogenum) Growth on Three HVAC Duct Materials. Environ. Int. 22 (4): 425-431; 1996.
    • (1996) Environ. Int. , vol.22 , Issue.4 , pp. 425-431
    • Chang, J.C.S.1    Foarde, K.K.2    Vanosdell, D.W.3
  • 3
    • 0029120838 scopus 로고
    • Growth evaluation of fungi (Penicillium and Aspergillus spp.) on ceiling tiles
    • Chang, J.C.S.; Foarde, K.K.; VanOsdell, D.W. Growth evaluation of fungi (Penicillium and Aspergillus spp.) On ceiling tiles. Atmos. Environ. 29: 2331-2337; 1995.
    • (1995) Atmos. Environ. , vol.29 , pp. 2331-2337
    • Chang, J.C.S.1    Foarde, K.K.2    VanOsdell, D.W.3
  • 5
    • 0021341875 scopus 로고
    • Penicillium allergic alveolitis: Faulty installation of central heating
    • Fergusson, R.J.; Milne, L.R.J.; Crompton, G.K. Penicillium allergic alveolitis: faulty installation of central heating. Thorax 39: 294-298; 1984.
    • (1984) Thorax , vol.39 , pp. 294-298
    • Fergusson, R.J.1    Milne, L.R.J.2    Crompton, G.K.3
  • 6
    • 2342432259 scopus 로고
    • Susceptibility of fiberglass duct liner to fungal (Penicillium chrysogenum) growth
    • Research Triangle Park, NC: EPA and Air and Waste Management Association; July
    • Foarde, K.K.; VanOsdell, D.W.; Chang, J.C.S. susceptibility of fiberglass duct liner to fungal (Penicillium chrysogenum) growth. In: Proc. of engineering solutions to indoor air quality problems, Research Triangle Park, NC: EPA and Air and Waste Management Association; July 1995.
    • (1995) Proc. of Engineering Solutions to Indoor Air Quality Problems
    • Foarde, K.K.1    VanOsdell, D.W.2    Chang, J.C.S.3
  • 7
    • 0001806624 scopus 로고    scopus 로고
    • Evaluation of fungal growth on fiberglass duct materials for various moisture, soil, use, and temperature conditions
    • Foarde, K.K.; VanOsdell, D.W.; Chang, J.C.S. Evaluation of Fungal growth on fiberglass duct materials for various moisture, soil, use, and temperature conditions. Indoor Air 6: 83-92; 1996a.
    • (1996) Indoor Air , vol.6 , pp. 83-92
    • Foarde, K.K.1    VanOsdell, D.W.2    Chang, J.C.S.3
  • 8
    • 0030144903 scopus 로고    scopus 로고
    • Static chamber method for evaluating the ability of indoor materials to support microbial growth
    • Philadelphia, PA: American Society for Testing and Materials
    • Foarde, K.; VanOsdell, D.; Chang, J. static chamber method for evaluating the ability of indoor materials to support microbial growth. ASTM STP 1286, Methods for characterizing indoor sources and sinks; Philadelphia, PA: American Society for Testing and Materials; 1996b: 87-97.
    • (1996) ASTM STP 1286, Methods for Characterizing Indoor Sources and Sinks , pp. 87-97
    • Foarde, K.1    VanOsdell, D.2    Chang, J.3
  • 9
    • 0009939386 scopus 로고
    • The airborne fungal population of representative British homes
    • Samson, R.A. et al., eds. Health implications of fungi in indoor environments
    • Hunter, C.A.; Lea, R.G. The airborne fungal population of representative British homes. In: Samson, R.A. et al., eds. Health implications of fungi in indoor environments. Air Qual. Monogr. 2: 141-153; 1995.
    • (1995) Air Qual. Monogr. , vol.2 , pp. 141-153
    • Hunter, C.A.1    Lea, R.G.2
  • 10
    • 0002520968 scopus 로고
    • Is porous insulation inside an hvac system compatible with a healthy building?
    • Atlanta, GA: American Society for Heating, Refrigeration and Air Conditioning Engineers
    • Morey, P.R; Williams, C. M. Is porous insulation inside an hvac system compatible with a healthy building? Healthy Buildings: Proc. IAQ '91, ASHRAE. Atlanta, GA: American Society for Heating, Refrigeration and Air Conditioning Engineers; 1991: 128-135.
    • (1991) Healthy Buildings: Proc. IAQ '91, ASHRAE , pp. 128-135
    • Morey, P.R.1    Williams, C.M.2
  • 14
    • 0024445150 scopus 로고
    • Allergies to molds caused by fungal spores in air conditioning equipment
    • Schata, M.; Jorde, W.; Elixman, J.H.; Linskens, H.F. Allergies to molds caused by fungal spores in air conditioning equipment. Environ. Int. 15: 177-179; 1989.
    • (1989) Environ. Int. , vol.15 , pp. 177-179
    • Schata, M.1    Jorde, W.2    Elixman, J.H.3    Linskens, H.F.4
  • 15
    • 0030143278 scopus 로고    scopus 로고
    • Design and operation of a dynamic test chamber for measurement of biocontaminant pollutant emission and control
    • Philadelphia, PA: American Society for Testing and Materials
    • VanOsdell, D.; Foarde, K.; Chang, J. Design and Operation of a Dynamic Test Chamber for Measurement of Biocontaminant Pollutant Emission and Control. ASTM STP 1286, Methods for characterizing indoor sources and sinks. Philadelphia, PA: American Society for Testing and Materials; 1996: 44-57.
    • (1996) ASTM STP 1286, Methods for Characterizing Indoor Sources and Sinks , pp. 44-57
    • VanOsdell, D.1    Foarde, K.2    Chang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.