메뉴 건너뛰기




Volumn 45, Issue 2, 1997, Pages 199-207

Simulation of 3D-treatment plans in head and neck tumors aided by matching of digitally reconstructed radiographs (DRR) and on-line distortion corrected simulator images

Author keywords

3D treatment planning; Digitally reconstructed radiographs (DRR); Field placement error; Head and neck tumor; Image distortion correction; Radiotherapy simulation

Indexed keywords

ARTICLE; COMPUTER SIMULATION; HEAD AND NECK CANCER; IMAGE RECONSTRUCTION; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING;

EID: 0031282216     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(97)00111-4     Document Type: Article
Times cited : (15)

References (25)
  • 1
    • 0028246946 scopus 로고
    • Transfer errors of planning CT to simulator: A possible source of setup inaccuracies?
    • [1] Bel, A., Bartelink, H., Vijlbrief, R.E. and Lebesque, J.V. Transfer errors of planning CT to simulator: a possible source of setup inaccuracies? Radiother. Oncol. 31: 176-180, 1994.
    • (1994) Radiother. Oncol. , vol.31 , pp. 176-180
    • Bel, A.1    Bartelink, H.2    Vijlbrief, R.E.3    Lebesque, J.V.4
  • 3
    • 0011058923 scopus 로고
    • An image correlation procedure for digitally reconstructed radiographs and electronic portal images
    • [3] Dong, L. and Boyer, A.L. An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Med. Phys. 21: 935, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 935
    • Dong, L.1    Boyer, A.L.2
  • 4
    • 0027280324 scopus 로고
    • The investigation and rectification of field placement errors in the delivery of complex head and neck fields
    • [4] Dunscombe, P.B., Fox, K., Loose, S. and Leszczynski, K. The investigation and rectification of field placement errors in the delivery of complex head and neck fields. Int. J. Radiat. Oncol. Biol. Phys. 26: 155-161, 1993.
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.26 , pp. 155-161
    • Dunscombe, P.B.1    Fox, K.2    Loose, S.3    Leszczynski, K.4
  • 5
    • 0029044934 scopus 로고
    • Reproducibility of patient positioning during routine radiotherapy, as assessed by an integrated megavoltage imaging system
    • [5] Gildersleve, J., Dearnaley, D.P., Evans, P.M. and Swindell, W. Reproducibility of patient positioning during routine radiotherapy, as assessed by an integrated megavoltage imaging system. Radiother. Oncol. 3: 151-160, 1995.
    • (1995) Radiother. Oncol. , vol.3 , pp. 151-160
    • Gildersleve, J.1    Dearnaley, D.P.2    Evans, P.M.3    Swindell, W.4
  • 6
    • 0011042416 scopus 로고
    • Automated evaluation of patient setup in three dimensions
    • Editor: K.G.A. Gilhuijs. Febo-druk, Enschede-Utrecht, Amsterdam
    • [6] Gilhuijs, K.G.A. Automated evaluation of patient setup in three dimensions. In: Automated Verification of Radiation Treatment Geometry, pp. 73-113. Editor: K.G.A. Gilhuijs. Febo-druk, Enschede-Utrecht, Amsterdam, 1995.
    • (1995) Automated Verification of Radiation Treatment Geometry , pp. 73-113
    • Gilhuijs, K.G.A.1
  • 7
    • 0029864905 scopus 로고    scopus 로고
    • Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data
    • [7] Gilhuijs, K.G.A., van de Ven, P.J.H. and van Herk, M. Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data. Med. Phys. 23; 389-399, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 389-399
    • Gilhuijs, K.G.A.1    Van De Ven, P.J.H.2    Van Herk, M.3
  • 9
    • 0023852327 scopus 로고
    • Accuracy in radiation field alignment in head and neck cancer: A prospective study
    • [9] Huizenga, H., Levendag, P.C., De Porre, P.M.Z.R. and Visser, A.G. Accuracy in radiation field alignment in head and neck cancer: a prospective study. Radiother. Oncol. 11: 181-187, 1988.
    • (1988) Radiother. Oncol. , vol.11 , pp. 181-187
    • Huizenga, H.1    Levendag, P.C.2    De Porre, P.M.Z.R.3    Visser, A.G.4
  • 10
    • 0021063113 scopus 로고
    • Pattern of care study: Hodgkin's disease relapse rate and adequacy of portals
    • [10] Kinzie, J.J., Hanks, G.E., Maclean, C.J. and Kramer, S. Pattern of care study: Hodgkin's disease relapse rate and adequacy of portals. Cancer 52: 2223-2226, 1983.
    • (1983) Cancer , vol.52 , pp. 2223-2226
    • Kinzie, J.J.1    Hanks, G.E.2    Maclean, C.J.3    Kramer, S.4
  • 11
    • 0017187996 scopus 로고
    • The effect of immobilization on localization error in the radiotherapy of head and neck cancer
    • [11] Marks, J.E. and Haus, A.G. The effect of immobilization on localization error in the radiotherapy of head and neck cancer. Clin. Radiol. 27: 175-177, 1976.
    • (1976) Clin. Radiol. , vol.27 , pp. 175-177
    • Marks, J.E.1    Haus, A.G.2
  • 12
    • 0028839880 scopus 로고
    • Evaluation of digitally reconstructed radiographs (DRRs) used for clinical radiotherapy: A phantom study
    • [12] McGee, K.P. and Das, L.J. Evaluation of digitally reconstructed radiographs (DRRs) used for clinical radiotherapy: a phantom study. Med. Phys. 22: 1815-1827, 1995.
    • (1995) Med. Phys. , vol.22 , pp. 1815-1827
    • McGee, K.P.1    Das, L.J.2
  • 13
    • 0025819830 scopus 로고
    • Is it necessary to repeat quality control procedures for head and neck patients?
    • [13] Mitine, C., Leunens, G., Verstraete, J. et al. Is it necessary to repeat quality control procedures for head and neck patients? Radiother. Oncol. 21: 201-210, 1991.
    • (1991) Radiother. Oncol. , vol.21 , pp. 201-210
    • Mitine, C.1    Leunens, G.2    Verstraete, J.3
  • 14
    • 0010994765 scopus 로고
    • Automatic correction of variable image distortion for accurate geometric measurements in digital angiographic systems
    • Editor: J, Richter. Linea Plus Druck. Frankfurt
    • [14] Onnasch, D.G.W., Prause, G.P.M. and Redmer, J.D.F. Automatic correction of variable image distortion for accurate geometric measurements in digital angiographic systems. In: Medizinische Physik, pp. 84-85. Editor: J, Richter. Linea Plus Druck. Frankfurt, 1995.
    • (1995) Medizinische Physik , pp. 84-85
    • Onnasch, D.G.W.1    Prause, G.P.M.2    Redmer, J.D.F.3
  • 15
    • 0001219475 scopus 로고
    • Minimization and maximization of functions
    • Editors: W.H. Press, S.A. Teukolsky, W.T. Vetterling and B.P. Flannery. Cambridge University Press, Cambridge. MA
    • [15] Press, W.H., Teukolsky, S.A., Vetterling, W.T. and Flannery, B.P. Minimization and maximization of functions. In: Numerical Recipes in C. The Art of Scientific Computing, 2nd edn., pp. 413-420. Editors: W.H. Press, S.A. Teukolsky, W.T. Vetterling and B.P. Flannery. Cambridge University Press, Cambridge. MA, 1992.
    • (1992) Numerical Recipes in C. The Art of Scientific Computing, 2nd Edn. , pp. 413-420
    • Press, W.H.1    Teukolsky, S.A.2    Vetterling, W.T.3    Flannery, B.P.4
  • 17
    • 0026724204 scopus 로고
    • Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements
    • [17] Rosenthal, S.A., Calvin, J.M., Goldwein, J.W., Smith, A.R. and Blitzer, P.H. Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements. Int. J. Radiat. Oncol. Biol. Phys. 23: 621-625, 1992.
    • (1992) Int. J. Radiat. Oncol. Biol. Phys. , vol.23 , pp. 621-625
    • Rosenthal, S.A.1    Calvin, J.M.2    Goldwein, J.W.3    Smith, A.R.4    Blitzer, P.H.5
  • 18
    • 0025837262 scopus 로고
    • Accurate characterization of image intensifier distortion
    • [18] Rudin, S., Bednarek, R.D. and Wong, R. Accurate characterization of image intensifier distortion. Med. Phys. 18: 1145-1151, 1991.
    • (1991) Med. Phys. , vol.18 , pp. 1145-1151
    • Rudin, S.1    Bednarek, R.D.2    Wong, R.3
  • 19
    • 0026040541 scopus 로고
    • 3D-Rekonstruktionen in der bestrahlungsplanung
    • [19] Schlegel, W. 3D-Rekonstruktionen in der Bestrahlungsplanung. Radiologe 31: 457-466, 1991.
    • (1991) Radiologe , vol.31 , pp. 457-466
    • Schlegel, W.1
  • 20
    • 0011060306 scopus 로고
    • Distortion correction of images from an XRII-chain for stereotactical treatment planning
    • Editor: J. Richter. Linea Plus Druck, Frankfurt
    • [20] Schramm, O., Debus, J., Seeber, S., Sroka, G. and Engenhart, R. Distortion correction of images from an XRII-chain for stereotactical treatment planning. In: Medizinische Physik, pp. 156-157. Editor: J. Richter. Linea Plus Druck, Frankfurt, 1995.
    • (1995) Medizinische Physik , pp. 156-157
    • Schramm, O.1    Debus, J.2    Seeber, S.3    Sroka, G.4    Engenhart, R.5
  • 21
    • 4243586183 scopus 로고
    • Einführung eines systems zur genauen lagebestimmung des zielpunktes in der röntgentherapiesimulation unter verwendung von DRR's und Simulationsaufnahmen: Erste Ansätze
    • Editor: M. Tautz. Typo-Knauer, Frankfurt
    • [21] Schramm, O., Sroka, G., Debus, J., Seeber, S., Hirschfeld, F. and Levegrün, S. Einführung eines Systems zur genauen Lagebestimmung des Zielpunktes in der Röntgentherapiesimulation unter Verwendung von DRR's und Simulationsaufnahmen: Erste Ansätze. In: Medizinische Physik, pp. 140-141. Editor: M. Tautz. Typo-Knauer, Frankfurt, 1994.
    • (1994) Medizinische Physik , pp. 140-141
    • Schramm, O.1    Sroka, G.2    Debus, J.3    Seeber, S.4    Hirschfeld, F.5    Levegrün, S.6
  • 22
    • 0028108992 scopus 로고
    • Is weekly port filming adequate for verifying patient position in modern radiation therapy?
    • [22] Valicenti, R.K., Michalski, J.M., Bosch, W.R. et al. Is weekly port filming adequate for verifying patient position in modern radiation therapy? Int. J. Radiat. Oncol. Biol. Phys. 30: 431-438, 1994.
    • (1994) Int. J. Radiat. Oncol. Biol. Phys. , vol.30 , pp. 431-438
    • Valicenti, R.K.1    Michalski, J.M.2    Bosch, W.R.3
  • 23
    • 0028914363 scopus 로고
    • Immobilizing and positioning patients for radiotherapy
    • [23] Verhey, L.J. Immobilizing and positioning patients for radiotherapy. Semin. Radiat. Oncol. 5: 100-114, 1995.
    • (1995) Semin. Radiat. Oncol. , vol.5 , pp. 100-114
    • Verhey, L.J.1
  • 25
    • 0019969222 scopus 로고
    • The influence of radiation therapy quality control on survival, responses and sites of relapse in oat cell carcinoma of the lung
    • [25] White, J.E., Chen, T., McCracken, J. et al. The influence of radiation therapy quality control on survival, responses and sites of relapse in oat cell carcinoma of the lung. Cancer, 50: 1084-1090, 1982.
    • (1982) Cancer , vol.50 , pp. 1084-1090
    • White, J.E.1    Chen, T.2    McCracken, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.