메뉴 건너뛰기




Volumn 44, Issue 11, 1997, Pages 1156-1159

Analog circuit for real-time computation of respiratory mechanical impedance in sleep studies

Author keywords

Airway resistance; Forced oscillation; Monitoring; Sleep apnea

Indexed keywords

BIOMEDICAL ENGINEERING; REAL TIME SYSTEMS; SIGNAL PROCESSING; SLEEP RESEARCH;

EID: 0031281679     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.641343     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0001500014 scopus 로고
    • Oscillation mechanics of the respiratory system,"
    • Bethesda, MD: Amer. Physiol. Soc., sect. 3, pt. I
    • R. Peslin and J. J. Fredberg.Oscillation mechanics of the respiratory system," in Handbook of Physiology, Vol. 3.. Bethesda, MD: Amer. Physiol. Soc., sect. 3, pt. I, 1986.
    • (1986) Handbook of Physiology , vol.3
    • Peslin, R.1    Fredberg, J.J.2
  • 2
    • 0024563401 scopus 로고
    • Total respiratory resistance and reactance as a measurement of response to bronchial challenge with histamine,"
    • J. A. Van Noord, J. Clement, K. P. Van de Woestijne, and M. Demedts.Total respiratory resistance and reactance as a measurement of response to bronchial challenge with histamine," Amer. Rev. Respir. Dis., vol. 139, pp. 921-926, 1989.
    • (1989) Amer. Rev. Respir. Dis. , vol.139 , pp. 921-926
    • Van Noord, J.A.1    Clement, J.2    Van De Woestijne, K.P.3    Demedts, M.4
  • 5
    • 0029144308 scopus 로고
    • Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels,"
    • R. Farré, M. Ferrer, M. Rotger, and D. Navajas.Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels," Eur. Respir. J., vol. 8, pp. 1222-1227, 1995.
    • (1995) Eur. Respir. J. , vol.8 , pp. 1222-1227
    • Farré, R.1    Ferrer, M.2    Rotger, M.3    Navajas, D.4
  • 6
    • 0039820879 scopus 로고    scopus 로고
    • Assessment of airway obstruction by means of the forced oscillation technique during application of CPAP in patients with SAS,"
    • D. Navajas, R. Faire, M. Rotger, and J. M. Montserrat.Assessment of airway obstruction by means of the forced oscillation technique during application of CPAP in patients with SAS," Amer. J. Respir. Crit. Care. Med.. vol. 153, no. 4, p. A772, 1996.
    • (1996) Amer. J. Respir. Crit. Care. Med.. , vol.153 , Issue.4
    • Navajas, D.1    Faire, R.2    Rotger, M.3    Montserrat, J.M.4
  • 7
    • 0030999889 scopus 로고    scopus 로고
    • Inspiratory dynamic obstruction detected by forced oscillation during CPAP. a model study,"
    • R. Farré, R. Peslin, M. Rotger, and D. Navajas.Inspiratory dynamic obstruction detected by forced oscillation during CPAP. A model study," Amer. J. Respir. Crit. Care. Med., vol. 155, pp. 952-956, 1997.
    • (1997) Amer. J. Respir. Crit. Care. Med. , vol.155 , pp. 952-956
    • Farré, R.1    Peslin, R.2    Rotger, M.3    Navajas, D.4
  • 8
    • 0030979814 scopus 로고    scopus 로고
    • System to generate forced oscillation superimposed to continuous positive airway pressure,"
    • R. Farré, M. Rotger, J. M. Montserrat, and D. Navajas.System to generate forced oscillation superimposed to continuous positive airway pressure," Eur. Respir. J., vol. 10, pp. 1349-1353, 1997.
    • (1997) Eur. Respir. J. , vol.10 , pp. 1349-1353
    • Farré, R.1    Rotger, M.2    Montserrat, J.M.3    Navajas, D.4
  • 11
    • 0021012863 scopus 로고
    • Computation of respiratory impedance from forced sinusoidal oscillations during breathing,"
    • J. G. Horowitz, S. D. Siegel, F. P. Primiano, Jr., and E. H. Chester.Computation of respiratory impedance from forced sinusoidal oscillations during breathing," Computers, Biomed. Res., vol. 16, pp. 499-521, 1983.
    • (1983) Computers, Biomed. Res. , vol.16 , pp. 499-521
    • Horowitz, J.G.1    Siegel, S.D.2    Primiano Jr., F.P.3    Chester, E.H.4
  • 12
    • 0027336888 scopus 로고
    • Respiratory mechanics studied by forced oscillations during artificial ventilation,"
    • R. Peslin, J. F. da Suva, C. Duvivier, and F. Chabot.Respiratory mechanics studied by forced oscillations during artificial ventilation," Eur. Respir. J., vol. 6, pp. 772-784, 1993.
    • (1993) Eur. Respir. J. , vol.6 , pp. 772-784
    • Peslin, R.1    Da Suva, J.F.2    Duvivier, C.3    Chabot, F.4
  • 13
    • 0024206039 scopus 로고
    • A new estimator to minimize the error due to breathing in the measurerent of respiratory impedance,"
    • D. Navajas, R. Farré, M. Rotger, and R. Peslin.A new estimator to minimize the error due to breathing in the measurerent of respiratory impedance," IEEE Trans. Biomed. Eng., vol. 35, pp. 1001-1005, 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 1001-1005
    • Navajas, D.1    Farré, R.2    Rotger, M.3    Peslin, R.4
  • 14
    • 0026020631 scopus 로고
    • Time-domain digital filter to improve signal-to-noise ratio in respiratory impedance measurements,"
    • R. Farré, M. Rotger, and D. Navajas.Time-domain digital filter to improve signal-to-noise ratio in respiratory impedance measurements," Med. Biol. Eng. CompuL, vol. 29, pp. 18-24, 1991.
    • (1991) Med. Biol. Eng. CompuL , vol.29 , pp. 18-24
    • Farré, R.1    Rotger, M.2    Navajas, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.