메뉴 건너뛰기




Volumn 12, Issue 9-10, 1997, Pages 1013-1020

Rapid determination of glucose and sucrose by an amperometric glucose- sensing electrode combined with an invertase/mutarotase-attached measuring cell

Author keywords

Enzyme electrode; Glucose; Sucrose

Indexed keywords

AMPEROMETRIC SENSORS; ELECTROCHEMICAL ELECTRODES; ENZYME IMMOBILIZATION; GLUCOSE; SUGAR (SUCROSE);

EID: 0031277821     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(97)00057-2     Document Type: Article
Times cited : (42)

References (30)
  • 1
    • 0001811654 scopus 로고
    • Enzyme electrode for food analysis
    • ed. G. Wagner & G. G. Guilbault. Dekker, New York
    • Bilitewski, U. (1994). Enzyme electrode for food analysis. In Food Biosensor Analysis, ed. G. Wagner & G. G. Guilbault. Dekker, New York, pp. 31-61.
    • (1994) Food Biosensor Analysis , pp. 31-61
    • Bilitewski, U.1
  • 2
    • 84909760333 scopus 로고
    • Amperometric sensor and immobilized enzyme electrode for the determination of enzymatic activities
    • Blum L. J., Betterand C., Coulet P. R. Amperometric sensor and immobilized enzyme electrode for the determination of enzymatic activities. Anal. Lett. 16B:1983;525-540.
    • (1983) Anal. Lett. , vol.16 , pp. 525-540
    • Blum, L.J.1    Betterand, C.2    Coulet, P.R.3
  • 3
    • 0026523045 scopus 로고
    • Amperometric glucose sensor with ferrocene as an electron transfer mediator
    • Dong S., Wang B., Liu B. Amperometric glucose sensor with ferrocene as an electron transfer mediator. Biosensors & Bioelectronics. 7:1992;215-222.
    • (1992) Biosensors & Bioelectronics , vol.7 , pp. 215-222
    • Dong, S.1    Wang, B.2    Liu, B.3
  • 4
    • 0002458119 scopus 로고
    • A carbon electrode sputtered with palladium and gold for the amperometric detection of hydrogen peroxide
    • Gorton L. A carbon electrode sputtered with palladium and gold for the amperometric detection of hydrogen peroxide. Anal. Chim. Acta. 178:1985;247.
    • (1985) Anal. Chim. Acta , vol.178 , pp. 247
    • Gorton, L.1
  • 5
    • 0025259877 scopus 로고
    • A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with poly(ester-sulfonic acid) cation-exchanger
    • Gorton L., Karan H. I., Hale P. D., Inagaki T., Okamoto Y., Skotheim T. A. A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with poly(ester-sulfonic acid) cation-exchanger. Anal. Chim. Acta. 228:1990;23-30.
    • (1990) Anal. Chim. Acta , vol.228 , pp. 23-30
    • Gorton, L.1    Karan, H.I.2    Hale, P.D.3    Inagaki, T.4    Okamoto, Y.5    Skotheim, T.A.6
  • 6
    • 0024095481 scopus 로고
    • Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • Harrison D. J., Turner R. F. B., Baltes H. P. Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. Anal. Chem. 60:1988;2002-2007.
    • (1988) Anal. Chem. , vol.60 , pp. 2002-2007
    • Harrison, D.J.1    Turner, R.F.B.2    Baltes, H.P.3
  • 7
    • 85008267423 scopus 로고
    • Comparative studies of the two forms of yeast invertase
    • Hoshino J., Momose A. Comparative studies of the two forms of yeast invertase. J. Gen. Appl. Microbiol. 12:1966;163-177.
    • (1966) J. Gen. Appl. Microbiol. , vol.12 , pp. 163-177
    • Hoshino, J.1    Momose, A.2
  • 8
    • 0021529356 scopus 로고
    • A convenient photochemical method to immobilize enzymes
    • Ichimura K. A convenient photochemical method to immobilize enzymes. J. Polym. Sci., Polym. Chem. Ed. 22:1984;2917-2928.
    • (1984) J. Polym. Sci., Polym. Chem. Ed. , vol.22 , pp. 2917-2928
    • Ichimura, K.1
  • 9
    • 0021485725 scopus 로고
    • Sequential determination of glutamate-oxalacetate transaminase and glutamate-pyruvate transaminase activities in serum using an immobilized bienzyme-poly(vinyl chloride) membrane electrode
    • Kihara K., Yasukawa E., Hirose S. Sequential determination of glutamate-oxalacetate transaminase and glutamate-pyruvate transaminase activities in serum using an immobilized bienzyme-poly(vinyl chloride) membrane electrode. Anal. Chem. 56:1983;1876-1880.
    • (1983) Anal. Chem. , vol.56 , pp. 1876-1880
    • Kihara, K.1    Yasukawa, E.2    Hirose, S.3
  • 10
    • 46549094565 scopus 로고
    • Simultaneous determination of sucrose and glucose in mixtures by flow injection analysis with immobilized enzymes
    • Masoom M., Townshend A. Simultaneous determination of sucrose and glucose in mixtures by flow injection analysis with immobilized enzymes. Anal. Chim. Acta. 171:1985;185-194.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 185-194
    • Masoom, M.1    Townshend, A.2
  • 11
    • 0002409689 scopus 로고
    • Determination of catecholamines by an electrochemical flow-injection detector with indium-tin oxide microelectrode arrays coated with Nafion
    • Matsue, T., Aoki, A., Abe, T. & Uchida, I. (1989). Determination of catecholamines by an electrochemical flow-injection detector with indium-tin oxide microelectrode arrays coated with Nafion. Chem. Lett., 133-136.
    • (1989) Chem. Lett. , pp. 133-136
    • Matsue, T.1    Aoki, A.2    Abe, T.3    Uchida, I.4
  • 12
    • 0019644658 scopus 로고
    • Ascorbate electrode for determination of L-ascorbic acid in food
    • Matsumoto K., Yamada K., Osajima Y. Ascorbate electrode for determination of L-ascorbic acid in food. Anal. Chem. 53:1981;1974-1979.
    • (1981) Anal. Chem. , vol.53 , pp. 1974-1979
    • Matsumoto, K.1    Yamada, K.2    Osajima, Y.3
  • 13
    • 0023903407 scopus 로고
    • Simultaneous determination of glucose, fructose, and sucrose in mixtures by amperometric flow injection analysis with immobilized enzyme reactors
    • Matsumoto K., Kamikado H., Matsubara H., Osajima Y. Simultaneous determination of glucose, fructose, and sucrose in mixtures by amperometric flow injection analysis with immobilized enzyme reactors. Anal. Chem. 60:1988;147-151.
    • (1988) Anal. Chem. , vol.60 , pp. 147-151
    • Matsumoto, K.1    Kamikado, H.2    Matsubara, H.3    Osajima, Y.4
  • 14
    • 33847802367 scopus 로고
    • A model for the amperometric enzyme electrode obtained through digital simulation and applied to the immobilized glucose oxidase system
    • Mell L. D., Maloy D. T. A model for the amperometric enzyme electrode obtained through digital simulation and applied to the immobilized glucose oxidase system. Anal. Chem. 47:1975;299-307.
    • (1975) Anal. Chem. , vol.47 , pp. 299-307
    • Mell, L.D.1    Maloy, D.T.2
  • 15
    • 0010618667 scopus 로고
    • Amperometric determination of cholinesterase with use of an immobilized enzyme electrode
    • Mizutani F., Tsuda K. Amperometric determination of cholinesterase with use of an immobilized enzyme electrode. Anal. Chim. Acta. 139:1982;359-362.
    • (1982) Anal. Chim. Acta , vol.139 , pp. 359-362
    • Mizutani, F.1    Tsuda, K.2
  • 16
    • 0002868796 scopus 로고
    • Sequential determination of L-lactate and lactate dehydrogenase with immobilized enzyme electrode
    • Mizutani F., Sasaki K., Shimura Y. Sequential determination of L-lactate and lactate dehydrogenase with immobilized enzyme electrode. Anal. Chem. 55:1983;35-38.
    • (1983) Anal. Chem. , vol.55 , pp. 35-38
    • Mizutani, F.1    Sasaki, K.2    Shimura, Y.3
  • 17
    • 4244186437 scopus 로고
    • An enzyme electrode for L-lactate with a chemically-amplified response
    • Mizutani F., Yamanaka T., Tanabe Y., Tsuda K. An enzyme electrode for L-lactate with a chemically-amplified response. Anal. Chim. Acta. 177:1985;153-166.
    • (1985) Anal. Chim. Acta , vol.177 , pp. 153-166
    • Mizutani, F.1    Yamanaka, T.2    Tanabe, Y.3    Tsuda, K.4
  • 18
    • 0002047942 scopus 로고
    • Trends in enzyme sensors
    • ed. D. L. Wise. Butterworths, Boston
    • Mizutani, F. & Asai, M. (1990a). Trends in enzyme sensors. In Bioinstrumentations, ed. D. L. Wise. Butterworths, Boston, pp. 314-353.
    • (1990) Bioinstrumentations , pp. 314-353
    • Mizutani, F.1    Asai, M.2
  • 19
    • 0025035884 scopus 로고
    • Simultaneous determination of glucose and sucrose by a glucose-sensing enzyme electrode combined with an invertase-attached cell
    • Mizutani F., Asai M. Simultaneous determination of glucose and sucrose by a glucose-sensing enzyme electrode combined with an invertase-attached cell. Anal. Chim. Acta. 236:1990;245-250.
    • (1990) Anal. Chim. Acta , vol.236 , pp. 245-250
    • Mizutani, F.1    Asai, M.2
  • 20
    • 0027535184 scopus 로고
    • Amperometric enzyme electrode with fast response to glucose using a layer of lipid-modified glucose oxidase and Nafion Anionic polymer
    • Mizutani F., Yabuki S., Katsura T. Amperometric enzyme electrode with fast response to glucose using a layer of lipid-modified glucose oxidase and Nafion Anionic polymer. Anal. Chim. Acta. 274:1993;201-207.
    • (1993) Anal. Chim. Acta , vol.274 , pp. 201-207
    • Mizutani, F.1    Yabuki, S.2    Katsura, T.3
  • 21
    • 0028810842 scopus 로고
    • Amperometric L-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples
    • Mizutani F., Yabuki S., Hirata Y. Amperometric L-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples. Anal. Chim. Acta. 314:1995;233-239.
    • (1995) Anal. Chim. Acta , vol.314 , pp. 233-239
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3
  • 22
    • 0030900721 scopus 로고    scopus 로고
    • Voltammetric enzyme sensor for urea using mercaptohydroquinone-modified gold electrode as the base transducer
    • in press
    • Mizutani, F., Yabuki, S. & Sato, Y. (1997). Voltammetric enzyme sensor for urea using mercaptohydroquinone-modified gold electrode as the base transducer. Biosensors & Bioelectronics (in press).
    • (1997) Biosensors & Bioelectronics
    • Mizutani, F.1    Yabuki, S.2    Sato, Y.3
  • 24
    • 0024765639 scopus 로고
    • Preparations of Langmuir-Blodgett films of enzyme-lipid complexes: A glucose sensor membrane
    • Okahata Y., Tsuruta T., Ijiro K., Ariga K. Preparations of Langmuir-Blodgett films of enzyme-lipid complexes: a glucose sensor membrane. Thin Solid Films. 180:1989;65-72.
    • (1989) Thin Solid Films , vol.180 , pp. 65-72
    • Okahata, Y.1    Tsuruta, T.2    Ijiro, K.3    Ariga, K.4
  • 26
    • 0002076024 scopus 로고
    • A combination of invertase reactor and glucose oxidase electrode for the successive determination of glucose and sucrose
    • Scheller F., Karsten Ch. A combination of invertase reactor and glucose oxidase electrode for the successive determination of glucose and sucrose. Anal. Chim. Acta. 155:1983;29-36.
    • (1983) Anal. Chim. Acta , vol.155 , pp. 29-36
    • Scheller, F.1    Karsten, Ch.2
  • 27
    • 0010583773 scopus 로고
    • Metabolism sensors
    • Elsevier, Amsterdam
    • Scheller, F. & Schubert, F. (1992). Metabolism sensors. In Biosensors. Elsevier, Amsterdam, pp. 85-252.
    • (1992) Biosensors , pp. 85-252
    • Scheller, F.1    Schubert, F.2
  • 28
    • 0021215735 scopus 로고
    • Electrostatic control of enzyme reactions: The mechanism of inhibition of glucose oxidase by putrescine
    • Voet J., Anderson E. C. Electrostatic control of enzyme reactions: the mechanism of inhibition of glucose oxidase by putrescine. Arch. Biochem. Biophys. 233:1984;88-92.
    • (1984) Arch. Biochem. Biophys. , vol.233 , pp. 88-92
    • Voet, J.1    Anderson, E.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.