메뉴 건너뛰기




Volumn 15, Issue 11, 1997, Pages 861-866

A new method for image separation of overlapped images from a two-layered printed circuit board (PCB)

Author keywords

Image separation; Machine vision; Two layered PCB; X ray imaging system

Indexed keywords

COMPUTER VISION; IMAGING SYSTEMS; OBJECT RECOGNITION; PRINTED CIRCUIT BOARDS; RECURSIVE FUNCTIONS; X RAYS;

EID: 0031276181     PISSN: 02628856     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0262-8856(97)00030-9     Document Type: Article
Times cited : (3)

References (16)
  • 4
    • 0039825552 scopus 로고
    • Automatic optical pattern inspection system using 3D profile measurement
    • B9/2-3. June
    • H. Oka, Automatic optical pattern inspection system using 3D profile measurement, Printed Circuit World Convention 5, B9/2-3. June, 1990.
    • (1990) Printed Circuit World Convention , vol.5
    • Oka, H.1
  • 7
    • 0027696505 scopus 로고
    • NASA evaluates automated inspection systems
    • R.M. Savage, NASA evaluates automated inspection systems. Test Meas. World (1993) 59-64.
    • (1993) Test Meas. World , pp. 59-64
    • Savage, R.M.1
  • 11
    • 0024607247 scopus 로고
    • X-ray inspection of three-dimensional solder joints
    • B. Baker, X-Ray inspection of three-dimensional solder joints, Electron. Manufact. (1989) 20-22.
    • (1989) Electron. Manufact. , pp. 20-22
    • Baker, B.1
  • 13
    • 0029546357 scopus 로고
    • Development of an inspection process for ball-grid-array technology using scanned-beam X-ray laminography
    • S.M. Rooks, B. Benhabib, K.C. Smith, Development of an inspection process for ball-grid-array technology using scanned-beam X-ray laminography, IEEE Trans. Components, Packaging, Manufact. Technol. A 18 (4) (1995) 851-861.
    • (1995) IEEE Trans. Components, Packaging, Manufact. Technol. A , vol.18 , Issue.4 , pp. 851-861
    • Rooks, S.M.1    Benhabib, B.2    Smith, K.C.3
  • 14
    • 0037580182 scopus 로고
    • Computerized tomography: The new medical X-ray technology
    • L.A. Shepp, J.B. Kruskal, Computerized tomography: the new medical X-ray technology, Am. Math. Monthly 85 (1979) 655-661.
    • (1979) Am. Math. Monthly , vol.85 , pp. 655-661
    • Shepp, L.A.1    Kruskal, J.B.2
  • 16
    • 0022566415 scopus 로고
    • An efficient and accurate camera calibration technique for 3D machine vision
    • IEEE, New York
    • R.Y. Tsai, An efficient and accurate camera calibration technique for 3D machine vision, IEEE Proc. Int. Conf. on Robotics and Automation, IEEE, New York, 1986, pp. 364-374.
    • (1986) IEEE Proc. Int. Conf. on Robotics and Automation , pp. 364-374
    • Tsai, R.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.