메뉴 건너뛰기




Volumn 12, Issue 6, 1997, Pages 295-298

Chemiluminescent Measurement of Oxalate in Serum by Detection of Hydrogen Peroxide Generated through Oxalate Oxidase

Author keywords

Chemiluminescence; Luminol; Oxalate oxidase; Porphyrin; Serum oxalate

Indexed keywords

BIOCHEMISTRY; CHEMILUMINESCENCE; OXALIC ACID; OXIDATION;

EID: 0031265919     PISSN: 15227235     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1099-1271(199711/12)12:6<295::aid-bio458>3.3.co;2-y     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0000712404 scopus 로고    scopus 로고
    • The primary hyperoxalurias
    • Coe FL, Favus MJ, Pak CYC, Parks JH, Preminger GM, editors. Philadelphia: Lippincott-Raven
    • Danpure CJ, Smith LH. The primary hyperoxalurias. In: Coe FL, Favus MJ, Pak CYC, Parks JH, Preminger GM, editors. Kidney stones: medical and surgical management. Philadelphia: Lippincott-Raven, 1996;859-81.
    • (1996) Kidney Stones: Medical and Surgical Management , pp. 859-881
    • Danpure, C.J.1    Smith, L.H.2
  • 2
    • 0008533645 scopus 로고
    • The effect of storage on serum oxalate values
    • Smith LH, Robertson WG, Finalayson B, editors. New York: Plenum Press
    • Maguire M, Fituri N, Keogh B, Costello J. The effect of storage on serum oxalate values. In: Smith LH, Robertson WG, Finalayson B, editors. Urolithiasis: clinical and basic research. New York: Plenum Press, 1981;963-7.
    • (1981) Urolithiasis: Clinical and Basic Research , pp. 963-967
    • Maguire, M.1    Fituri, N.2    Keogh, B.3    Costello, J.4
  • 3
    • 0026055773 scopus 로고
    • Modified enzyme-based colorimetric assay of urinary and plasma oxalate with improved sensitivity and no ascorbate interference: Reference values and sample handling procedures
    • Wilson DM, Liedtke RR. Modified enzyme-based colorimetric assay of urinary and plasma oxalate with improved sensitivity and no ascorbate interference: reference values and sample handling procedures. Clin Chem 1991;37:1229-35.
    • (1991) Clin Chem , vol.37 , pp. 1229-1235
    • Wilson, D.M.1    Liedtke, R.R.2
  • 4
    • 0025368801 scopus 로고
    • Ion chromatographic determination of plasma oxalate in healthy subjects, in patients with chronic renal failure and in cases of hyperoxaluric syndromes
    • Petrarulo M, Bianco O, Marangella M, Pellegrino S, Linari F, Mentasti E. Ion chromatographic determination of plasma oxalate in healthy subjects, in patients with chronic renal failure and in cases of hyperoxaluric syndromes. J Chromatogr 1990;511:223-31.
    • (1990) J Chromatogr , vol.511 , pp. 223-231
    • Petrarulo, M.1    Bianco, O.2    Marangella, M.3    Pellegrino, S.4    Linari, F.5    Mentasti, E.6
  • 6
    • 0026050685 scopus 로고
    • The determination of oxalate in urine and plasma by high performance liquid chromatography
    • Fry DR, Starkey BJ. The determination of oxalate in urine and plasma by high performance liquid chromatography. Ann Clin Biochem 1991;28:581-7.
    • (1991) Ann Clin Biochem , vol.28 , pp. 581-587
    • Fry, D.R.1    Starkey, B.J.2
  • 9
    • 0022602943 scopus 로고
    • Measurement of plasma oxalate in healthy subjects and in patients with chronic renal failure using immobilised oxalate oxidase
    • Kasidas GP, Rose GA. Measurement of plasma oxalate in healthy subjects and in patients with chronic renal failure using immobilised oxalate oxidase. Clin Chim Acta 1986;154:49-58.
    • (1986) Clin Chim Acta , vol.154 , pp. 49-58
    • Kasidas, G.P.1    Rose, G.A.2
  • 10
    • 0026505328 scopus 로고
    • Hematin as a peroxidase substitute in hydrogen peroxide determinations
    • Genfa Z, Dasgupta PK. Hematin as a peroxidase substitute in hydrogen peroxide determinations. Anal Chem 1992;64:517-22.
    • (1992) Anal Chem , vol.64 , pp. 517-522
    • Genfa, Z.1    Dasgupta, P.K.2
  • 11
    • 0001300620 scopus 로고
    • Metal porphyrin chemiluminescence reaction and application to immunoassay
    • Motsenbocker M, Ichimori Y, Kondo K. Metal porphyrin chemiluminescence reaction and application to immunoassay. Anal Chem 1993;65:397-402.
    • (1993) Anal Chem , vol.65 , pp. 397-402
    • Motsenbocker, M.1    Ichimori, Y.2    Kondo, K.3
  • 12
    • 0029799296 scopus 로고    scopus 로고
    • Luminol chemiluminescence-based porphyrin assays without hydrogen peroxide: A spectral study of mechanism and enhancement
    • Poupon-Fleuret C, Steghens JP, Bernengo JC. Luminol chemiluminescence-based porphyrin assays without hydrogen peroxide: a spectral study of mechanism and enhancement. Analyst 1996;121:1539-43.
    • (1996) Analyst , vol.121 , pp. 1539-1543
    • Poupon-Fleuret, C.1    Steghens, J.P.2    Bernengo, J.C.3
  • 13
    • 0347723582 scopus 로고
    • Purification of luminol for use in enhanced chemiluminescence immunoassay
    • Schölmerich J, Andreesen A, Kapp A, Ernst M, Woods WG, editors. New York: Wiley
    • Stott RAW, Kricka LJ. Purification of luminol for use in enhanced chemiluminescence immunoassay. In: Schölmerich J, Andreesen A, Kapp A, Ernst M, Woods WG, editors. Bioluminescence and chemiluminescence: new perspectives. New York: Wiley, 1987;237-40.
    • (1987) Bioluminescence and Chemiluminescence: New Perspectives , pp. 237-240
    • Stott, R.A.W.1    Kricka, L.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.