메뉴 건너뛰기




Volumn 17, Issue 6, 1997, Pages 330-336

Reference sample microsphere method to measure blood flow effects on small intestinal perfusion in the rat

Author keywords

Blood flow; Laser Doppler; Microspheres; Rat; Small intestine

Indexed keywords

MICROSPHERE;

EID: 0031265331     PISSN: 01676865     EISSN: None     Source Type: Journal    
DOI: 10.1159/000179249     Document Type: Article
Times cited : (2)

References (25)
  • 1
    • 0017262388 scopus 로고
    • Reference sample method for cardiac output and regional blood flow determinations in the rat
    • Malik A, Kaplan J, Saba T: Reference sample method for cardiac output and regional blood flow determinations in the rat, J Appl Physiol 1976:40:472-475.
    • (1976) J Appl Physiol , vol.40 , pp. 472-475
    • Malik, A.1    Kaplan, J.2    Saba, T.3
  • 2
    • 0021181658 scopus 로고
    • The radiolabeled microsphcre technique in gut blood flow measurement: Current practice
    • Levine BA, Sirinek K, Gaskill HV: The radiolabeled microsphcre technique in gut blood flow measurement: Current practice, J Surg Res 1984;37:241-245.
    • (1984) J Surg Res , vol.37 , pp. 241-245
    • Levine, B.A.1    Sirinek, K.2    Gaskill, H.V.3
  • 3
    • 0022107007 scopus 로고
    • Laser Doppler, H2-clcarance, and microsphcre estimates of mucosal blood How
    • Kvietys P, Shepherd A, Granger N: Laser Doppler, H2-clcarance, and microsphcre estimates of mucosal blood How, Ann J Phvsiol 1985;249:G221-G227.
    • (1985) Ann J Phvsiol , vol.249 , pp. G221-G227
    • Kvietys, P.1    Shepherd, A.2    Granger, N.3
  • 4
    • 17144445363 scopus 로고
    • Continuous measurement of intestinal mucosal blood flow by laser-Doppler velocimetry
    • Shepherd A, Ricdcl G: Continuous measurement of intestinal mucosal blood flow by laser-Doppler velocimetry, Am J Physiol 1982:242: G668-G672.
    • (1982) Am J Physiol , vol.242 , pp. G668-G672
    • Shepherd, A.1    Ricdcl, G.2
  • 5
    • 0021504847 scopus 로고
    • Measurements of gastric mucosal blood How by hydrogen gas clearance
    • Ashley S, Cheung L: Measurements of gastric mucosal blood How by hydrogen gas clearance, Am J Physiol 1984;247:G339-G345.
    • (1984) Am J Physiol , vol.247 , pp. G339-G345
    • Ashley, S.1    Cheung, L.2
  • 6
    • 0022540159 scopus 로고
    • Assessment of blood flow in the small intestine with laser Doppler flowmetrv
    • Ahn H, Lindhagen J, Nilsson G, Lundgren O: Assessment of blood flow in the small intestine with laser Doppler flowmetrv, Scand J Gastroenterol 1986;21:863-870.
    • (1986) Scand J Gastroenterol , vol.21 , pp. 863-870
    • Ahn, H.1    Lindhagen, J.2    Nilsson, G.3    Lundgren, O.4
  • 7
    • 0026297690 scopus 로고
    • Mucosal/submucosal blood How in the gut wall determined by local washout of 133 Xenon
    • Mortensen P, Olsen J, Billow J, Hagc E, Edel-fors S: Mucosal/submucosal blood How in the gut wall determined by local washout of 133 Xenon, Acta Physiol Scand 1991;143(suppl 603): 75-84.
    • (1991) Acta Physiol Scand , vol.143 , pp. 75-84
    • Mortensen, P.1    Olsen, J.2    Billow, J.3    Hagc, E.4    Edel-Fors, S.5
  • 8
  • 9
    • 0019069404 scopus 로고
    • Reference sample microspherc method: Cardiac output and blood flows in conscious rats
    • Ishise S, Pcgram B, Yamamoto J, Kitamura Y, Frölich E: Reference sample microspherc method: Cardiac output and blood flows in conscious rats, Am J Physiol 1980;239:H443-H449.
    • (1980) Am J Physiol , vol.239 , pp. H443-H449
    • Ishise, S.1    Pcgram, B.2    Yamamoto, J.3    Kitamura, Y.4    Frölich, E.5
  • 11
    • 0015142919 scopus 로고
    • Some sources of error in measuring regional blood flow with radioactive microspheres
    • Buckberg G, Luck J, Payne B, Hoffman J, Archie J, Fixier D: Some sources of error in measuring regional blood flow with radioactive microspheres, J Appl Physiol 1971;31:598-604.
    • (1971) J Appl Physiol , vol.31 , pp. 598-604
    • Buckberg, G.1    Luck, J.2    Payne, B.3    Hoffman, J.4    Archie, J.5    Fixier, D.6
  • 12
    • 0017333127 scopus 로고
    • Cardiovascular effects of radioactive microspherc suspensions and Tween 80 solutions
    • Millard R, Baig H, Vainer S: Cardiovascular effects of radioactive microspherc suspensions and Tween 80 solutions, Am J Physiol 1977; 232:H331-H334.
    • (1977) Am J Physiol , vol.232 , pp. H331-H334
    • Millard, R.1    Baig, H.2    Vainer, S.3
  • 13
    • 0017659325 scopus 로고
    • Systemic effects of microsphcres in conscious rats
    • Tsuchiya M, Walsh G, Frölich E: Systemic effects of microsphcres in conscious rats, Am J Physiol 1977;233:H617-H621.
    • (1977) Am J Physiol , vol.233 , pp. H617-H621
    • Tsuchiya, M.1    Walsh, G.2    Frölich, E.3
  • 14
    • 0028849420 scopus 로고
    • Cardiovascular effects of microspherc suspending agent, Tween 80, in pigs
    • Grund F, Sommerschild H, Kirkeboen K, lle-bekk A: Cardiovascular effects of microspherc suspending agent, Tween 80, in pigs, Acta Physiol Scand 1995:155:331-332.
    • (1995) Acta Physiol Scand , vol.155 , pp. 331-332
    • Grund, F.1    Sommerschild, H.2    Kirkeboen, K.3    Lle-Bekk, A.4
  • 15
    • 0028335405 scopus 로고
    • Effects of intra-arterial injections of colorectal microspheres on systemic hemodynamics and regional blood flow in the rat
    • Kobayashi N, Kobayashi K, Kouno K, Horina-ka S, Yagi S: Effects of intra-arterial injections of colorectal microspheres on systemic hemodynamics and regional blood flow in the rat, Am J Physiol 1994:266:H1910-H1917.
    • (1994) Am J Physiol , vol.266 , pp. H1910-H1917
    • Kobayashi, N.1    Kobayashi, K.2    Kouno, K.3    Horina-Ka, S.4    Yagi, S.5
  • 16
    • 85025576017 scopus 로고
    • Laser Doppler Flow-mctry, cd l.Norwell, Kluwer
    • Shephard AP, Öberg PA: Laser Doppler Flow-mctry, cd l.Norwell, Kluwer, 1990.
    • (1990)
    • Shephard, A.P.1    Öberg, P.A.2
  • 17
    • 0026209407 scopus 로고
    • Influence of fiber diameter and probe geometry on the measuring depth of laser Doppler flowmetrv in the gastrointestinal application
    • Johansson K, Jakobsson A, Lindahl K, Lindhagen J, Lundgren O, Nilsson G: Influence of fiber diameter and probe geometry on the measuring depth of laser Doppler flowmetrv in the gastrointestinal application, Int J Microcirc Clin Exp 1991:10:219-229.
    • (1991) Int J Microcirc Clin Exp , vol.10 , pp. 219-229
    • Johansson, K.1    Jakobsson, A.2    Lindahl, K.3    Lindhagen, J.4    Lundgren, O.5    Nilsson, G.6
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement, Lancet 1986;i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0025641888 scopus 로고
    • Hemorrhage produces depression in blood flow which persists despite fluid resuscitation
    • Wang P, Hauptman J, Chaudry I: Hemorrhage produces depression in blood flow which persists despite fluid resuscitation, Circ Shock 1990:32:307-318.
    • (1990) Circ Shock , vol.32 , pp. 307-318
    • Wang, P.1    Hauptman, J.2    Chaudry, I.3
  • 21
    • 85025545668 scopus 로고
    • Effects of anesthetics on regional hemodynamics in normovolemic and hemorrhaged rats
    • Seydc W, McGowan L, Lund N, Duling B, Longnecker D: Effects of anesthetics on regional hemodynamics in normovolemic and hemorrhaged rats, Am J Physiol 1985:249:11164-11173.
    • (1985) Am J Physiol , vol.249 , pp. 11164-11173
    • Seydc, W.1    McGowan, L.2    Lund, N.3    Duling, B.4    Longnecker, D.5
  • 22
    • 0024215660 scopus 로고
    • Increase in capillary blood flow and relative hematocrit in skeletal muscle following acute normovolemic anemia
    • Lindbom L, Mirahashemi S, Intaglietta M, Ar-fors K: Increase in capillary blood flow and relative hematocrit in skeletal muscle following acute normovolemic anemia, Acta Physiol Scand 1988:134:503-512.
    • (1988) Acta Physiol Scand , vol.134 , pp. 503-512
    • Lindbom, L.1    Mirahashemi, S.2    Intaglietta, M.3    Ar-Fors, K.4
  • 23
    • 0024997310 scopus 로고
    • Correlation of laser Doppler wave patterns with underlying nticrovascular anatomy
    • Braverman IM, Keh A, Goldniinz D: Correlation of laser Doppler wave patterns with underlying nticrovascular anatomy, J Invest Dermatol 1990:95:283-286.
    • (1990) J Invest Dermatol , vol.95 , pp. 283-286
    • Braverman, I.M.1    Keh, A.2    Goldniinz, D.3
  • 24
    • 0022487050 scopus 로고
    • Evaluation of laser-Doppler flowmetrv as a measure of tissue blood flow
    • Sntits G, Roman R, Lombard J: Evaluation of laser-Doppler flowmetrv as a measure of tissue blood flow, J Appl Physiol 1986;61:666-672.
    • (1986) J Appl Physiol , vol.61 , pp. 666-672
    • Sntits, G.1    Roman, R.2    Lombard, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.