메뉴 건너뛰기




Volumn 19, Issue 5, 1997, Pages 491-500

Superelastic nickel titanium alloy retraction springs - An experimental investigation of force systems

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; NICKEL; STAINLESS STEEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0031255548     PISSN: 01415387     EISSN: None     Source Type: Journal    
DOI: 10.1093/ejo/19.5.491     Document Type: Article
Times cited : (30)

References (26)
  • 1
    • 0015321758 scopus 로고
    • A use hypothesis for 55 nitinol wire in orthodontics
    • Andreasen G F, Brady P R 1972 A use hypothesis for 55 nitinol wire in orthodontics. Angle Orthodontist 42: 172-177
    • (1972) Angle Orthodontist , vol.42 , pp. 172-177
    • Andreasen, G.F.1    Brady, P.R.2
  • 4
  • 6
    • 0026781804 scopus 로고
    • An experimental apparatus for the simulation of three-dimensional movements in orthodontics
    • Bourauel C, Drescher D, Thier M 1992a An experimental apparatus for the simulation of three-dimensional movements in orthodontics. Journal of Biomedical Engineering 14: 371-378
    • (1992) Journal of Biomedical Engineering , vol.14 , pp. 371-378
    • Bourauel, C.1    Drescher, D.2    Thier, M.3
  • 7
    • 0026583375 scopus 로고
    • Numerische Untersuchung kieferorthopädischer Behandlungselemente aus pseudoelastischen NiTi-Legierungen
    • Bourauel C, Nolte L P, Drescher D 1992b Numerische Untersuchung kieferorthopädischer Behandlungselemente aus pseudoelastischen NiTi-Legierungen. Biomedizinische Technik 37: 46-53
    • (1992) Biomedizinische Technik , vol.37 , pp. 46-53
    • Bourauel, C.1    Nolte, L.P.2    Drescher, D.3
  • 8
    • 0027545912 scopus 로고
    • Computergestützte Entwicklung kieferorthopädischer Behandlungselemente aus NiTi-Memory-Legierungen am Beispiel einer pseudoelastischen Retraktionsfeder
    • Bourauel C, Drescher D, Nolte LP 1993 Computergestützte Entwicklung kieferorthopädischer Behandlungselemente aus NiTi-Memory-Legierungen am Beispiel einer pseudoelastischen Retraktionsfeder. Fortschritte der Kieferorthopädie 53: 45-56
    • (1993) Fortschritte der Kieferorthopädie , vol.53 , pp. 45-56
    • Bourauel, C.1    Drescher, D.2    Nolte, L.P.3
  • 9
    • 36849132052 scopus 로고
    • Effect of low-temperature phase changes on the mechanical properties of alloys near composition of TiNi
    • Buehler W J, Gilfrich J V, Wiley R C 1963 Effect of low-temperature phase changes on the mechanical properties of alloys near composition of TiNi. Journal of Applied Physics 34: 1475-1484
    • (1963) Journal of Applied Physics , vol.34 , pp. 1475-1484
    • Buehler, W.J.1    Gilfrich, J.V.2    Wiley, R.C.3
  • 12
    • 0017049116 scopus 로고
    • Three-dimensional large displacement analysis of orthodontic appliances
    • De Franco J, Koenig H, Burstone C J 1976 Three-dimensional large displacement analysis of orthodontic appliances. Journal of Biomechanics 9: 793-801
    • (1976) Journal of Biomechanics , vol.9 , pp. 793-801
    • De Franco, J.1    Koenig, H.2    Burstone, C.J.3
  • 13
    • 0026176392 scopus 로고
    • Application of the orthodontic measurement and simulation system (OMSS) in orthodontics
    • Drescher D, Bourauel C, Thier M 1991 Application of the orthodontic measurement and simulation system (OMSS) in orthodontics. European Journal of Orthodontics 13: 169-178
    • (1991) European Journal of Orthodontics , vol.13 , pp. 169-178
    • Drescher, D.1    Bourauel, C.2    Thier, M.3
  • 14
    • 0022069701 scopus 로고
    • Biomechanical design and clinical evaluation of a new canine-retraction spring
    • Gjessing P 1985 Biomechanical design and clinical evaluation of a new canine-retraction spring. American Journal of Orthodontics 87: 353-362
    • (1985) American Journal of Orthodontics , vol.87 , pp. 353-362
    • Gjessing, P.1
  • 17
    • 0016098808 scopus 로고
    • Analysis of generalized curved beams for orthodontic applications
    • Koenig H A, Burstone C J 1974 Analysis of generalized curved beams for orthodontic applications. Journal of Biomechanics 7: 429-435
    • (1974) Journal of Biomechanics , vol.7 , pp. 429-435
    • Koenig, H.A.1    Burstone, C.J.2
  • 21
    • 0021854956 scopus 로고
    • A new method for finite element simulation of orthodontic appliance-teeth-periodontium-alveolus system
    • Miyakawa O, Shiokawa N, Matsuura I, Hanada K 1985 A new method for finite element simulation of orthodontic appliance-teeth-periodontium-alveolus system. Journal of Biomechanics 18: 277-284
    • (1985) Journal of Biomechanics , vol.18 , pp. 277-284
    • Miyakawa, O.1    Shiokawa, N.2    Matsuura, I.3    Hanada, K.4
  • 25
    • 0017718005 scopus 로고
    • Experimentally determined force systems from vertically activated orthodontic loops
    • Vanderby R, Burstone C J, Solonche D J, Ratches JA 1977 Experimentally determined force systems from vertically activated orthodontic loops. Angle Orthodontist 47: 272-279
    • (1977) Angle Orthodontist , vol.47 , pp. 272-279
    • Vanderby, R.1    Burstone, C.J.2    Solonche, D.J.3    Ratches, J.A.4
  • 26
    • 0015979479 scopus 로고
    • Analysis of space closing springs in orthodontics
    • Yang T Y, Baldwin J J 1974 Analysis of space closing springs in orthodontics. Journal of Biomechanics 7: 21-28
    • (1974) Journal of Biomechanics , vol.7 , pp. 21-28
    • Yang, T.Y.1    Baldwin, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.