메뉴 건너뛰기




Volumn 19, Issue 8, 1997, Pages 690-695

The design and performance of an experimental external fixator with variable axial stiffness and a compressive force transducer

Author keywords

Compression; Compression spring; External fixator; Sheep; Tibia; Transducer

Indexed keywords

BEARINGS (MACHINE PARTS); BONE; COMPUTATIONAL METHODS; FORCE MEASUREMENT; FRACTURE FIXATION; SPRINGS (COMPONENTS); STIFFNESS; TRANSDUCERS;

EID: 0031253597     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(97)00037-4     Document Type: Article
Times cited : (11)

References (14)
  • 2
    • 77049238959 scopus 로고
    • The biomechanics of fracture healing
    • Yamagishi M., Yoshimura Y. The biomechanics of fracture healing. J. Bone Joint Surg. 37A:1955;1035-1068.
    • (1955) J. Bone Joint Surg. , vol.37 , pp. 1035-1068
    • Yamagishi, M.1    Yoshimura, Y.2
  • 3
    • 0017750467 scopus 로고
    • Effects of compression and cyclic loading on fracture healing: A quantitative biomechanical study
    • White A. A., Panjabi M. M., Southwick W. O. Effects of compression and cyclic loading on fracture healing: a quantitative biomechanical study. J. Biomech. 10:1977;233-239.
    • (1977) J. Biomech. , vol.10 , pp. 233-239
    • White, A.A.1    Panjabi, M.M.2    Southwick, W.O.3
  • 4
    • 0019419864 scopus 로고
    • Comparison of cyclic loading versus constant compression in the treatment of long-bone fractures in the rabbit
    • Wolf J. W., White A. A., Panjabi M. M., Southwick W. O. Comparison of cyclic loading versus constant compression in the treatment of long-bone fractures in the rabbit. J. Bone Joint Surg. 63A:1981;805-810.
    • (1981) J. Bone Joint Surg. , vol.63 , pp. 805-810
    • Wolf, J.W.1    White, A.A.2    Panjabi, M.M.3    Southwick, W.O.4
  • 5
    • 0022413393 scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship A. E., Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J. Bone Joint Surg. 67B:1985;428-442.
    • (1985) J. Bone Joint Surg. , vol.67 , pp. 428-442
    • Goodship, A.E.1    Kenwright, J.2
  • 6
    • 0026864027 scopus 로고
    • Fracture stiffness measurement in the assessment and management of tibial fractures
    • Richardson J. B., Kenwright J., Cunningham J. L. Fracture stiffness measurement in the assessment and management of tibial fractures. Clin. Biomech. 7:1992;75-79.
    • (1992) Clin. Biomech. , vol.7 , pp. 75-79
    • Richardson, J.B.1    Kenwright, J.2    Cunningham, J.L.3
  • 9
  • 10
    • 0018490883 scopus 로고
    • Analysis of single-sided external fracture fixation
    • Evans M., Kenwright J., Tanner K. E. Analysis of single-sided external fracture fixation. Eng. Med. 8:1979;133-137.
    • (1979) Eng. Med. , vol.8 , pp. 133-137
    • Evans, M.1    Kenwright, J.2    Tanner, K.E.3
  • 11
    • 0020364649 scopus 로고
    • Rigidity and stress analysis of external fracture fixation devices - A theoretical approach
    • Chao E. Y. S., Kasman R. A., An K. N. Rigidity and stress analysis of external fracture fixation devices - a theoretical approach. J. Biomech. 15:1982;971-983.
    • (1982) J. Biomech. , vol.15 , pp. 971-983
    • Chao, E.Y.S.1    Kasman, R.A.2    An, K.N.3
  • 13
    • 0010676367 scopus 로고
    • Measurement errors and instrument inaccuracies
    • ed. B. E. Jones. Adam Hilger, Bristol
    • Cunningham, M. J., Measurement errors and instrument inaccuracies. In Instrument Science and Technology, ed. B. E. Jones. Adam Hilger, Bristol, 1983.
    • (1983) Instrument Science and Technology
    • Cunningham, M.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.