메뉴 건너뛰기




Volumn 19, Issue 8, 1997, Pages 681-689

Program for generation of three-dimensional finite element mesh from magnetic resonance imaging scans of human limbs

Author keywords

Finite element modelling; Image processing; Limb

Indexed keywords

BONE; C (PROGRAMMING LANGUAGE); COMPUTER SIMULATION; DOS; FINITE ELEMENT METHOD; IMAGE PROCESSING; MAGNETIC RESONANCE IMAGING; MUSCLE; RANDOM ACCESS STORAGE; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 0031253581     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(97)00039-8     Document Type: Article
Times cited : (26)

References (16)
  • 1
    • 0030049518 scopus 로고    scopus 로고
    • Stress and strain distribution within the intact femur: Compression or bending?
    • Taylor M. E., Tanner K. E., Freeman M. A. R., Yettram A. L. Stress and strain distribution within the intact femur: compression or bending? Med. Eng. Phys. 18(2):1996;122-131.
    • (1996) Med. Eng. Phys. , vol.18 , Issue.2 , pp. 122-131
    • Taylor, M.E.1    Tanner, K.E.2    Freeman, M.A.R.3    Yettram, A.L.4
  • 3
    • 0028341087 scopus 로고
    • Three-dimensional computer model of the human buttocks in vivo
    • Todd B. A., Thacker J. G. Three-dimensional computer model of the human buttocks in vivo. J. Rehab. Res. and Dev. 31(2):1994;111-119.
    • (1994) J. Rehab. Res. and Dev. , vol.31 , Issue.2 , pp. 111-119
    • Todd, B.A.1    Thacker, J.G.2
  • 4
    • 0027751317 scopus 로고
    • Modelling the mechanics of narrowly contained soft tissues: The effect of specification of Poisson's ratio
    • Vannah W. H., Childress D. S. Modelling the mechanics of narrowly contained soft tissues: the effect of specification of Poisson's ratio. J. Rehab. Res. and Dev. 30(2):1993;205-209.
    • (1993) J. Rehab. Res. and Dev. , vol.30 , Issue.2 , pp. 205-209
    • Vannah, W.H.1    Childress, D.S.2
  • 5
    • 0017969268 scopus 로고
    • Deformation and stresses of soft body tissue of a sitting person
    • Chow W. W., Odell E. I. Deformation and stresses of soft body tissue of a sitting person. J. Biomech. Eng. 100:1974;79-87.
    • (1974) J. Biomech. Eng. , vol.100 , pp. 79-87
    • Chow, W.W.1    Odell, E.I.2
  • 6
    • 0010676460 scopus 로고
    • Stress distribution in a physical buttock model: Effect of simulated bone geometry
    • Candadai R. S., Reddy N. P. Stress distribution in a physical buttock model: effect of simulated bone geometry. J. Biomech. 15:1992;493-504.
    • (1992) J. Biomech. , vol.15 , pp. 493-504
    • Candadai, R.S.1    Reddy, N.P.2
  • 7
    • 0029411893 scopus 로고
    • Development of non-linear finite element modelling of the below-knee prosthetic socket interface
    • Zhang M., Lord M., Turner A. R., Roberts V. C. Development of non-linear finite element modelling of the below-knee prosthetic socket interface. Med. Eng. Phys. 17(8):1995;59-66.
    • (1995) Med. Eng. Phys. , vol.17 , Issue.8 , pp. 59-66
    • Zhang, M.1    Lord, M.2    Turner, A.R.3    Roberts, V.C.4
  • 8
    • 0030200561 scopus 로고    scopus 로고
    • Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation
    • Silver-Thorn M. B., Childress D. S. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation. J. Rehab. Res. and Dev. 33(3):1996;227-238.
    • (1996) J. Rehab. Res. and Dev. , vol.33 , Issue.3 , pp. 227-238
    • Silver-Thorn, M.B.1    Childress, D.S.2
  • 9
    • 0030200946 scopus 로고    scopus 로고
    • Design of a 3-D surface scanner for lower limbs prosthetics
    • Commean P. K., Smith K. E., Vanier M. Design of a 3-D surface scanner for lower limbs prosthetics. J. Rehab. Res. and Dev. 33(3):1996;267-278.
    • (1996) J. Rehab. Res. and Dev. , vol.33 , Issue.3 , pp. 267-278
    • Commean, P.K.1    Smith, K.E.2    Vanier, M.3
  • 11
    • 0028913283 scopus 로고
    • Left ventricular boundry detection from spatio-temporal volumetric computed tomography images
    • Tu H. K., Matheny A., Goldgof D. B., Bunke H. Left ventricular boundry detection from spatio-temporal volumetric computed tomography images. Comput. Med. Imag. Graph. 19(1):1995;27-46.
    • (1995) Comput. Med. Imag. Graph. , vol.19 , Issue.1 , pp. 27-46
    • Tu, H.K.1    Matheny, A.2    Goldgof, D.B.3    Bunke, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.