메뉴 건너뛰기




Volumn 43, Issue 5, 1997, Pages

Development of a custom designed TAH using rapid prototyping

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; COMPUTER AIDED DESIGN; FABRICATION; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE IMAGING; MODELS; RAPID PROTOTYPING; THREE DIMENSIONAL;

EID: 0031239406     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199709000-00063     Document Type: Conference Paper
Times cited : (8)

References (6)
  • 1
    • 0026193202 scopus 로고
    • Determination of critical pericardial dimensions in patients with dilated cardiomyopathy
    • Pantalos GM, Richenbacher WE, Karwnde SV, Gay WA Jr: Determination of critical pericardial dimensions in patients with dilated cardiomyopathy. ASAIO Trans 37: M252-M253, 1991.
    • (1991) ASAIO Trans , vol.37
    • Pantalos, G.M.1    Richenbacher, W.E.2    Karwnde, S.V.3    Gay Jr., W.A.4
  • 2
    • 0026184802 scopus 로고
    • Anatomic fit study for development of a one piece total artificial heart
    • Shiono M, Shah AS, Sasaki T, et al.: Anatomic fit study for development of a one piece total artificial heart. ASAIO Trans 37: M254-M255, 1991.
    • (1991) ASAIO Trans , vol.37
    • Shiono, M.1    Shah, A.S.2    Sasaki, T.3
  • 3
    • 0028966348 scopus 로고
    • Study of cardiac structures in relation to the pericardial cavity for total artificial heart implantation
    • Komoda T, Uyama C, Maeta H, Ozaki K: Study of cardiac structures in relation to the pericardial cavity for total artificial heart implantation. Artif Organs 19: 178-184, 1995.
    • (1995) Artif Organs , vol.19 , pp. 178-184
    • Komoda, T.1    Uyama, C.2    Maeta, H.3    Ozaki, K.4
  • 4
    • 0026054642 scopus 로고
    • Cardiac output requirements and maximum dimensions for a neonate total artificial heart
    • Koppert E, Pantalos GM, Tieleman R, Swier P, Burns GL: Cardiac output requirements and maximum dimensions for a neonate total artificial heart. Int J Artif Organs 14: 707-715, 1991.
    • (1991) Int J Artif Organs , vol.14 , pp. 707-715
    • Koppert, E.1    Pantalos, G.M.2    Tieleman, R.3    Swier, P.4    Burns, G.L.5
  • 5
    • 0025642574 scopus 로고
    • A new type of the motor-driven blood pump for artificial heart
    • Cheon GJ, Kim HC, Min BG, Han DC: A new type of the motor-driven blood pump for artificial heart. J Biomed Eng 112: 473-475, 1990.
    • (1990) J Biomed Eng , vol.112 , pp. 473-475
    • Cheon, G.J.1    Kim, H.C.2    Min, B.G.3    Han, D.C.4
  • 6
    • 0342780399 scopus 로고
    • A human model of the moving-actuator type total artificial heart (TAH)
    • Tokyo, Springer-Verlag
    • Chang JK, et al: A human model of the moving-actuator type total artificial heart (TAH), In Artificial Heart 4, Tokyo, Springer-Verlag, 1993, pp. 134-138.
    • (1993) Artificial Heart , vol.4 , pp. 134-138
    • Chang, J.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.