메뉴 건너뛰기




Volumn 43, Issue 5, 1997, Pages

A new double lumen balloon catheter for retrograde cerebral perfusion via jugular vein cannulation

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; BLOOD VESSELS; BRAIN; CARDIOVASCULAR SURGERY; HEMODYNAMICS; MEDICAL PROBLEMS; PRESSURE;

EID: 0031239397     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199709000-00080     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 1
    • 0026468857 scopus 로고
    • Deep hypothermia systemic circulatory arrest and continuous retrograde cerebral perfusion for surgery of aortic arch aneurysm
    • Ueda K, Miki S, Kusuhara K, Okita Y, et al: Deep hypothermia systemic circulatory arrest and continuous retrograde cerebral perfusion for surgery of aortic arch aneurysm. Cardiothorac Surg 6: 36-41, 1992.
    • (1992) Cardiothorac Surg , vol.6 , pp. 36-41
    • Ueda, K.1    Miki, S.2    Kusuhara, K.3    Okita, Y.4
  • 2
    • 0000441064 scopus 로고
    • Morphological and functional study of internal jugular vein valve
    • Murase M, Maeda M, Murayama H, et al: Morphological and functional study of internal jugular vein valve. Jap J Cardiovasc Surg 22: 383-386, 1993.
    • (1993) Jap J Cardiovasc Surg , vol.22 , pp. 383-386
    • Murase, M.1    Maeda, M.2    Murayama, H.3
  • 3
    • 0027401102 scopus 로고
    • Selective jugular cannulation for safer retrograde cerebral perfusion
    • Okamoto H, Sato K, Yasuura K, et al: Selective jugular cannulation for safer retrograde cerebral perfusion. Ann Thorac Surg 55: 538-540, 1993.
    • (1993) Ann Thorac Surg , vol.55 , pp. 538-540
    • Okamoto, H.1    Sato, K.2    Yasuura, K.3
  • 4
    • 0343214850 scopus 로고
    • Angiographic consideration of blood flow in retrograde cerebral perfusion with Japanese monkey
    • Miyamoto S, Soeda T, Uchida Y, et al: Angiographic consideration of blood flow in retrograde cerebral perfusion with Japanese monkey. J Jpn Coll Angiol 35: 145-152, 1995.
    • (1995) J Jpn Coll Angiol , vol.35 , pp. 145-152
    • Miyamoto, S.1    Soeda, T.2    Uchida, Y.3
  • 5
    • 0026676583 scopus 로고
    • Simple hypothermia retrograde cerebral perfusion during aortic arch surgery
    • Takamoto S, Matsuda T, Miyata S, et al: Simple hypothermia retrograde cerebral perfusion during aortic arch surgery. J Cardiovasc Surg 33: 560-567, 1992.
    • (1992) J Cardiovasc Surg , vol.33 , pp. 560-567
    • Takamoto, S.1    Matsuda, T.2    Miyata, S.3
  • 6
  • 7
    • 0021922149 scopus 로고
    • A comparison of flow gradients across disposable arterial perfusion cannula
    • Brodman R, Siegel H, Frater R, et al: A comparison of flow gradients across disposable arterial perfusion cannula. Ann Thorac Surg 39: 225-233, 1985.
    • (1985) Ann Thorac Surg , vol.39 , pp. 225-233
    • Brodman, R.1    Siegel, H.2    Frater, R.3
  • 8
    • 0027969312 scopus 로고
    • Optimal perfusion pressure for experimental retrograde cerebral perfusion
    • Nojima T, Magara T, Mori A, et al: Optimal perfusion pressure for experimental retrograde cerebral perfusion. J Card Surg 9: 548-559, 1994.
    • (1994) J Card Surg , vol.9 , pp. 548-559
    • Nojima, T.1    Magara, T.2    Mori, A.3
  • 9
    • 0026902751 scopus 로고
    • A clinical assessment of efficacy in continuous retrograde cerebral perfusion method
    • Imamaki M, Hashimoto A, Koyanagi H, et al: A clinical assessment of efficacy in continuous retrograde cerebral perfusion method. Jap J Thorac Surg 45: 755-758, 1992.
    • (1992) Jap J Thorac Surg , vol.45 , pp. 755-758
    • Imamaki, M.1    Hashimoto, A.2    Koyanagi, H.3
  • 11
    • 0028889079 scopus 로고
    • Retrograde cerebral perfusion during hypothermia circulatory arrest reduces neurologic morbidity
    • Deeb GM, Jenkins E, Bolling SF, et al: Retrograde cerebral perfusion during hypothermia circulatory arrest reduces neurologic morbidity. J Thorac Cardiovasc Surg 109: 259-268, 1995.
    • (1995) J Thorac Cardiovasc Surg , vol.109 , pp. 259-268
    • Deeb, G.M.1    Jenkins, E.2    Bolling, S.F.3
  • 12
    • 0028241423 scopus 로고
    • Basic studies on the effects of stenotic connection on mechanical blood hemolysis
    • Zhou D, Fujimasu H, Umezu M, et al: Basic studies on the effects of stenotic connection on mechanical blood hemolysis. Jpn J Artif Organs 23: 559-563, 1994.
    • (1994) Jpn J Artif Organs , vol.23 , pp. 559-563
    • Zhou, D.1    Fujimasu, H.2    Umezu, M.3
  • 13
    • 0029822301 scopus 로고    scopus 로고
    • Analysis of the hemolysis on colliding against the surface
    • Yasuda T, Funakubo A, Fukui Y: Analysis of the hemolysis on colliding against the surface. Jpn J Artif Organs 25: 632-635, 1996.
    • (1996) Jpn J Artif Organs , vol.25 , pp. 632-635
    • Yasuda, T.1    Funakubo, A.2    Fukui, Y.3
  • 14
    • 0015736687 scopus 로고
    • Hemolysis in blood induced under pressure
    • Eurenius S, Smith RM: Hemolysis in blood induced under pressure. Anesthesiology 39: 650-651, 1973.
    • (1973) Anesthesiology , vol.39 , pp. 650-651
    • Eurenius, S.1    Smith, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.