Long term animal experiments with an intraventricular axial flow blood pump

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL ORGANS; CARDIOLOGY; CARDIOVASCULAR SYSTEM; HEART VALVE PROSTHESES; HEMODYNAMICS; IMPLANTS (SURGICAL); MINIATURE RADIO EQUIPMENT; TRANSPLANTATION (SURGICAL);

EID: 0031238972     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199709000-00074     Document Type: Conference Paper
Times cited : (12)

References (7)
  • 1
    • 0343650521 scopus 로고
    • A new left ventricular assist device - A miniature intraventricular axial flow blood pump
    • Yamazaki K, Kitamura M, Eishi K, et al.: A new left ventricular assist device - a miniature intraventricular axial flow blood pump. J Clin Exp Med 154: 133-134, 1990.
    • (1990) J Clin Exp Med , vol.154 , pp. 133-134
    • Yamazaki, K.1    Kitamura, M.2    Eishi, K.3
  • 2
    • 0025876311 scopus 로고
    • A new left ventricular assist device - A miniature intraventricular axial flow blood pump
    • Yamazaki K, Kitamura M, Shiikawa A, et al.: A new left ventricular assist device - a miniature intraventricular axial flow blood pump. Jpn J Artif Organs 20: 705-710, 1991.
    • (1991) Jpn J Artif Organs , vol.20 , pp. 705-710
    • Yamazaki, K.1    Kitamura, M.2    Shiikawa, A.3
  • 3
    • 0026566916 scopus 로고
    • A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex
    • Yamazaki K, Umezu M, Koyanagi H, et al.: A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex. Trans Am Soc Artif Intern Organs 38: 679-683, 1992.
    • (1992) Trans Am Soc Artif Intern Organs , vol.38 , pp. 679-683
    • Yamazaki, K.1    Umezu, M.2    Koyanagi, H.3
  • 4
    • 0342345321 scopus 로고
    • Development of a miniature intraventricular axial flow blood pump as a fully implantable LVAD for bridge use
    • Tokyo, Springer-Verlag
    • Yamazaki K, Umezu M, Koyanagi H, et al.: Development of a miniature intraventricular axial flow blood pump as a fully implantable LVAD for bridge use, in Heart Replacement, Artificial Heart, Vol 4, Tokyo, Springer-Verlag, 1993, pp. 273-278.
    • (1993) Heart Replacement, Artificial Heart , vol.4 , pp. 273-278
    • Yamazaki, K.1    Umezu, M.2    Koyanagi, H.3
  • 5
    • 0027426348 scopus 로고
    • Development of a miniature intraventricular axial flow blood pump
    • Yamazaki K, Umezu M, Koyanagi H, et al.: Development of a miniature intraventricular axial flow blood pump. Trans Am Soc Artif Intern Organs 39: 224-230, 1993.
    • (1993) Trans Am Soc Artif Intern Organs , vol.39 , pp. 224-230
    • Yamazaki, K.1    Umezu, M.2    Koyanagi, H.3
  • 6
    • 0028792154 scopus 로고
    • An intraventricular axial flow blood pump integrated with bearing purge system
    • Yamazaki K, Kormos R, Mori T, et al.: An intraventricular axial flow blood pump integrated with bearing purge system. Trans Am Soc Artif Intern Organs 41: 327-332, 1995.
    • (1995) Trans Am Soc Artif Intern Organs , vol.41 , pp. 327-332
    • Yamazaki, K.1    Kormos, R.2    Mori, T.3
  • 7
    • 0343650519 scopus 로고
    • The "Cool-Seal" concept: A low temperature mechanical seal with recirculated purge system for rotary blood pumps
    • Akutsu X, T Koyanagi XH (eds), Tokyo, Springer-Verlag
    • Yamazaki K, Mori T, Tomioka J, et al.: The "Cool-Seal" concept: a low temperature mechanical seal with recirculated purge system for rotary blood pumps, in Akutsu X, T Koyanagi XH (eds), Artificial Heart 6, Tokyo, Springer-Verlag, 19xx, pp. XX-XX.
    • (1920) Artificial Heart 6
    • Yamazaki, K.1    Mori, T.2    Tomioka, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.