Volumn 21, Issue 4, 1997, Pages 258-264

On-line rapid detection of urease-producing bacteria with a novel bulk acoustic wave ammonia sensor

Author keywords

Ammonia; Bacterial detection; Bulk acoustic wave sensor; Proteus vulgaris

Indexed keywords

AMMONIA; CELL CULTURE; CHEMICAL SENSORS; ENZYMES; GAS PERMEABLE MEMBRANES; GROWTH KINETICS; PH EFFECTS; REGRESSION ANALYSIS; SOLUTIONS; THERMAL EFFECTS;

EID: 0031238785     PISSN: 01410229     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0141-0229(97)00039-2     Document Type: Article
Times cited : (7)

References (21)
  • 3
    • 84966178826 scopus 로고
    • Detection technology: The key to environmental biotechnology
    • McCormick, D. Detection technology: The key to environmental biotechnology. Bio/Technology 1986, 4, 419-422
    • (1986) Bio/Technology , vol.4 , pp. 419-422
    • McCormick, D.1
  • 6
    • 0019624152 scopus 로고
    • Selectivity characteristics of ammonia-gas sensor based on a polymer membrane electrode
    • Fraticeill, Y. M. and Meyerhoff, M. E. Selectivity characteristics of ammonia-gas sensor based on a polymer membrane electrode. Anal. Chem. 1981, 53, 1857-1861
    • (1981) Anal. Chem. , vol.53 , pp. 1857-1861
    • Fraticeill, Y.M.1    Meyerhoff, M.E.2
  • 7
    • 0001429337 scopus 로고
    • Polymer membrane electrode based potentiometric ammonia gas sensor
    • Meyerhoff, M. E. Polymer membrane electrode based potentiometric ammonia gas sensor. Anal. Chem. 1980, 52, 1532-1534
    • (1980) Anal. Chem. , vol.52 , pp. 1532-1534
    • Meyerhoff, M.E.1
  • 8
    • 0001428002 scopus 로고
    • Performance characteristics of gas-sensing membrane probes
    • Bailey, P. L. and Riley, M. Performance characteristics of gas-sensing membrane probes. The Analyst 1975, 100, 145-155
    • (1975) The Analyst , vol.100 , pp. 145-155
    • Bailey, P.L.1    Riley, M.2
  • 9
    • 0019632211 scopus 로고
    • Amperometric determination of ammonia gas with immobilized nitrifying bacteria
    • Karube, I., Okado, T., and Suzuki, S. Amperometric determination of ammonia gas with immobilized nitrifying bacteria. Anal. Chem. 1981, 53, 1852-1854
    • (1981) Anal. Chem. , vol.53 , pp. 1852-1854
    • Karube, I.1    Okado, T.2    Suzuki, S.3
  • 10
    • 0016427278 scopus 로고
    • Continuous real-time monitoring of metabolic parameters in growing bacterial cultures
    • Ladenson, J. H., Huebner, M., and Marr, J. J. Continuous real-time monitoring of metabolic parameters in growing bacterial cultures. Anal. Biochem. 1975, 63, 56-67
    • (1975) Anal. Biochem. , vol.63 , pp. 56-67
    • Ladenson, J.H.1    Huebner, M.2    Marr, J.J.3
  • 11
    • 0015910597 scopus 로고
    • Rapid determination of ammonia in a perchloric acid supernate from blood by use of an ammonia-specific electrode
    • Proeiss, H. F. and Wright, B. W. Rapid determination of ammonia in a perchloric acid supernate from blood by use of an ammonia-specific electrode. Clin. Chem. 1973, 19, 1162-1169
    • (1973) Clin. Chem. , vol.19 , pp. 1162-1169
    • Proeiss, H.F.1    Wright, B.W.2
  • 14
    • 0001287053 scopus 로고
    • Piezoelectric immunosensor for the detection of Canadida albicans microbes
    • Muramatsu, H., Kajiwara, K., Tamiya, E., and Karube, I. Piezoelectric immunosensor for the detection of Canadida albicans microbes. Anal. Chim. Acta 1986, 188, 257-261
    • (1986) Anal. Chim. Acta , vol.188 , pp. 257-261
    • Muramatsu, H.1    Kajiwara, K.2    Tamiya, E.3    Karube, I.4
  • 17
    • 84865280983 scopus 로고
    • Detection of viruses and bacteria with piezoelectric immunosensors
    • Konig, B. and Gratzel, M. Detection of viruses and bacteria with piezoelectric immunosensors. Anal. Lett. 1993, 26(8), 1567-1585
    • (1993) Anal. Lett. , vol.26 , Issue.8 , pp. 1567-1585
    • Konig, B.1    Gratzel, M.2
  • 18
    • 0029116025 scopus 로고
    • A goat-anti-human igg modified piezoimmunosensor for Staphylococcus aureus detection
    • Deng, L., He, F. J., Jiang, T. J., Nie, L. H., and Yao, S. Z. A goat-anti-human IgG modified piezoimmunosensor for Staphylococcus aureus detection. J. Microbiol. Meth. 1995, 23, 229-234
    • (1995) J. Microbiol. Meth. , vol.23 , pp. 229-234
    • Deng, L.1    He, F.J.2    Jiang, T.J.3    Nie, L.H.4    Yao, S.Z.5
  • 19
    • 0343181993 scopus 로고
    • The adaptation of coated piezoelectric devices for use in the detection of gases in aqueous solutions
    • Webber, L. M. and Guilbault, G. G. The adaptation of coated piezoelectric devices for use in the detection of gases in aqueous solutions. Anal. Chim. Acta 1977, 93, 145-151
    • (1977) Anal. Chim. Acta , vol.93 , pp. 145-151
    • Webber, L.M.1    Guilbault, G.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.