메뉴 건너뛰기




Volumn 10, Issue 5-6, 1997, Pages 289-302

A review of the phi factor during runaway conditions

Author keywords

[No Author keywords available]

Indexed keywords

ADIABATIC REACTION; PHI FACTOR; RUNAWAY CONDITIONS;

EID: 0031225208     PISSN: 09504230     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0950-4230(97)00018-1     Document Type: Review
Times cited : (24)

References (14)
  • 1
    • 16644362758 scopus 로고
    • Thermal hazard evaluation by an accelerating rate calorimeter
    • [1] Townsend, D. I. and Tou, J. C., Thermal hazard evaluation by an accelerating rate calorimeter. Thermochimica Acta, 1980, 37, 1-30.
    • (1980) Thermochimica Acta , vol.37 , pp. 1-30
    • Townsend, D.I.1    Tou, J.C.2
  • 2
    • 0010549366 scopus 로고
    • Emergency relief system design using DIERS technology
    • [2] Fisher et al., Emergency relief system design using DIERS technology. A.I.Chem.E., 1992.
    • (1992) A.I.Chem.E.
    • Fisher1
  • 3
    • 0020190508 scopus 로고
    • Emergency venting requirements
    • [3] Huff, J. E., Emergency venting requirements. Plant/Operations Progress, 1992, 1(4), 211.
    • (1992) Plant/Operations Progress , vol.1 , Issue.4 , pp. 211
    • Huff, J.E.1
  • 4
    • 0000924044 scopus 로고
    • PHI-TEC-enhanced vent sizing calorimeter application and comparison with existing devices
    • Cambridge, MA, 7-9 March
    • [4] Singh, J., PHI-TEC-enhanced vent sizing calorimeter application and comparison with existing devices. International Symposium on Runaway Reactions, Cambridge, MA, 7-9 March 1989.
    • (1989) International Symposium on Runaway Reactions
    • Singh, J.1
  • 6
    • 0004221757 scopus 로고
    • Chemical reaction hazards
    • [6] Barton, J. and Rogers, R., Chemical reaction hazards. IChemE, 1993.
    • (1993) IChemE
    • Barton, J.1    Rogers, R.2
  • 9
    • 0029234853 scopus 로고
    • Application of ARC thermokinetic data to the design of safety schemes for industrial reactors
    • [9] Townsend, D. I., Ferguson, H. D. and Kohlbrand, H. T., Application of ARC thermokinetic data to the design of safety schemes for industrial reactors. Process Safety Progress, 1995, 14(1), 71.
    • (1995) Process Safety Progress , vol.14 , Issue.1 , pp. 71
    • Townsend, D.I.1    Ferguson, H.D.2    Kohlbrand, H.T.3
  • 10
    • 0009052623 scopus 로고
    • The use/misuse of the 100 degree rule in the interpretation of thermal hazard tests
    • Cambridge, MA, 7-9 March
    • [10] Hofelich, T. C. and Thomas, R. C., The use/misuse of the 100 degree rule in the interpretation of thermal hazard tests. International Symposium on Runaway Reactions, Cambridge, MA, 7-9 March 1989.
    • (1989) International Symposium on Runaway Reactions
    • Hofelich, T.C.1    Thomas, R.C.2
  • 11
    • 0001474873 scopus 로고
    • Specific features of kinetic evaluation in calorimetric studies of runaway reactions
    • [11] Kossoy, A. and Koludarova, E., Specific features of kinetic evaluation in calorimetric studies of runaway reactions. Journal of Loss Prevention in the Process Industries, 1995, 8(4), 229.
    • (1995) Journal of Loss Prevention in the Process Industries , vol.8 , Issue.4 , pp. 229
    • Kossoy, A.1    Koludarova, E.2
  • 13
    • 0010611169 scopus 로고    scopus 로고
    • private communication
    • [13] Wagner, S., private communication.
    • Wagner, S.1
  • 14
    • 0010583314 scopus 로고
    • A systematic approach of the assessment of thermal safety of chemical processes
    • [14] Stoessel, F., A systematic approach of the assessment of thermal safety of chemical processes. Chemical Engineering Progress, 1993, 4.
    • (1993) Chemical Engineering Progress , vol.4
    • Stoessel, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.