메뉴 건너뛰기




Volumn 21, Issue 2, 1997, Pages 108-116

A high-performance bioluminescent trienzymatic sensor for D-sorbitol based on a novel approach of the sensing layer design

Author keywords

Bacterial bioluminescence; Compartmentalization; Fiber optic sensor; Immobilized enzymes; Luciferase; NAD(P)H:FMN oxidoreductase; Sorbitol dehydrogenase

Indexed keywords

BACTERIA; BIOASSAY; CHEMILUMINESCENCE; COMPOSITION EFFECTS; ENZYME IMMOBILIZATION; REACTION KINETICS;

EID: 0031215057     PISSN: 01410229     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0141-0229(96)00233-5     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0028533245 scopus 로고
    • Enhancement of the response of a lactate oxidase/peroxidase-based fiberoptic sensor by compartmentalization of the enzyme layer
    • Berger, A. and Blum, L. J. Enhancement of the response of a lactate oxidase/peroxidase-based fiberoptic sensor by compartmentalization of the enzyme layer. Enzyme Microb. Technol. 1994, 16, 979-984
    • (1994) Enzyme Microb. Technol. , vol.16 , pp. 979-984
    • Berger, A.1    Blum, L.J.2
  • 2
    • 0024580444 scopus 로고
    • Fibre-optic sensor with co-immobilized bacterial bioluminescence enzymes
    • Gautier, S. M., Blum, L. J., and Coulet, P. R. Fibre-optic sensor with co-immobilized bacterial bioluminescence enzymes. Biosensors 1989, 4, 181-194
    • (1989) Biosensors , vol.4 , pp. 181-194
    • Gautier, S.M.1    Blum, L.J.2    Coulet, P.R.3
  • 3
    • 0026781710 scopus 로고
    • Dehydrogenase activity monitoring by flow-injection analysis combined with luminescence-based fibre-optic sensors
    • Gautier, S. M., Blum, L. J., and Coulet, P. R. Dehydrogenase activity monitoring by flow-injection analysis combined with luminescence-based fibre-optic sensors. Anal. Chim. Acta 1992, 266, 331-338
    • (1992) Anal. Chim. Acta , vol.266 , pp. 331-338
    • Gautier, S.M.1    Blum, L.J.2    Coulet, P.R.3
  • 4
    • 0025177742 scopus 로고
    • Fibre-optic biosensor based on luminescence and immobilized enzymes: Microdetermination of sorbitol, ethanol, and oxaloacetate
    • Gautier, S. M., Blum, L. J., and Coulet, P. R. Fibre-optic biosensor based on luminescence and immobilized enzymes: Microdetermination of sorbitol, ethanol, and oxaloacetate. J. Biolum. Chemilum. 1990, 5, 57-63
    • (1990) J. Biolum. Chemilum. , vol.5 , pp. 57-63
    • Gautier, S.M.1    Blum, L.J.2    Coulet, P.R.3
  • 5
    • 0004165234 scopus 로고
    • Highly stable bioluminescence-based fiberoptic sensor using immobilized enzymes from V. harveyi
    • Blum, L. J., Gautier, S. M., and Coulet, P. R. Highly stable bioluminescence-based fiberoptic sensor using immobilized enzymes from V. harveyi. Anal. Lett. 1989, 22(10), 2211-2222
    • (1989) Anal. Lett. , vol.22 , Issue.10 , pp. 2211-2222
    • Blum, L.J.1    Gautier, S.M.2    Coulet, P.R.3
  • 6
    • 0000033633 scopus 로고
    • Bacterial luciferase: Assay, purification, and properties
    • (DeLuca, M., Ed.). Academic Press, New York
    • Hastings, J. W., Baldwin, T. O., and Nicoli, M. Z. Bacterial luciferase: Assay, purification, and properties. In: Methods in Enzymology Vol. 57 (DeLuca, M., Ed.). Academic Press, New York, 1978, 135-152
    • (1978) Methods in Enzymology , vol.57 , pp. 135-152
    • Hastings, J.W.1    Baldwin, T.O.2    Nicoli, M.Z.3
  • 7
    • 0011233788 scopus 로고
    • New immobilized enzyme membranes for tailor-made biosensors
    • Assolant-Vinet, C. H. and Coulet, P. R. New immobilized enzyme membranes for tailor-made biosensors. Anal. Lett. 1986, 19 (7&8), 875-885
    • (1986) Anal. Lett. , vol.19 , Issue.7-8 , pp. 875-885
    • Assolant-Vinet, C.H.1    Coulet, P.R.2
  • 8
    • 0001168843 scopus 로고
    • Luminescence fiber-optic biosensor
    • Blum, L. J., Gautier, S. M., and Coulet, P. R. Luminescence fiber-optic biosensor. Anal. Lett. 1988, 21(5), 717-726
    • (1988) Anal. Lett. , vol.21 , Issue.5 , pp. 717-726
    • Blum, L.J.1    Gautier, S.M.2    Coulet, P.R.3
  • 9
    • 0025128392 scopus 로고
    • Multi-function fibre-optic sensor for the bioluminescent flow determination of ATP or NADH
    • Gautier, S. M., Blum, L. J., and Coulet, P. R. Multi-function fibre-optic sensor for the bioluminescent flow determination of ATP or NADH. Anal. Chim. Acta 1990, 235, 243-253
    • (1990) Anal. Chim. Acta , vol.235 , pp. 243-253
    • Gautier, S.M.1    Blum, L.J.2    Coulet, P.R.3
  • 10
  • 11
    • 85012423220 scopus 로고
    • Sorbitol dehydrogenase (polyol dehydrogenase) from sheep liver
    • 2nd English Ed. (Bergmeyer, H. U. and Gawehn, K., Eds.), Verlag Chemie International, Deerfield Beach, FL
    • Sorbitol dehydrogenase (polyol dehydrogenase) from sheep liver. In: Methods of Enzymatic Analysis Vol. 1, 2nd English Ed. (Bergmeyer, H. U. and Gawehn, K., Eds.), Verlag Chemie International, Deerfield Beach, FL, 1974, 512-513
    • (1974) Methods of Enzymatic Analysis , vol.1 , pp. 512-513
  • 12
    • 0016411968 scopus 로고
    • Initial velocity and product inhibition studies on L-iditol: NAD oxidoreductase
    • Christensen, U., Tüchsen, E., and Andersen, B. Initial velocity and product inhibition studies on L-iditol: NAD oxidoreductase. Acta Chem. Scand. 1975, B29, 81-87
    • (1975) Acta Chem. Scand. , vol.B29 , pp. 81-87
    • Christensen, U.1    Tüchsen, E.2    Andersen, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.