Volumn 98, Issue 1-2, 1997, Pages 1-15

Role of supplemental aeration in improving overloaded first-stage RBC performance

Author keywords

Dissolved oxygen; First stage; Performance; Removal rate; Rotating biological contactor (RBC); Supplemental aeration

Indexed keywords

AMMONIA; BIOCHEMICAL OXYGEN DEMAND; BIOLOGICAL WATER TREATMENT; BIOMASS; OXYGEN; PH; TEMPERATURE MEASUREMENT; WASTEWATER TREATMENT; WATER TREATMENT PLANTS;

EID: 0031214575     PISSN: 00496979     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02128647     Document Type: Article
Times cited : (15)

References (13)
  • 13
    • 42549094029 scopus 로고
    • Design of Municipal Wastewater Treatment Plants
    • Alexandria, VA
    • Water Environment Federation (WEF): 1992, 'Design of Municipal Wastewater Treatment Plants', Manual of practice No. 8, Alexandria, VA.
    • (1992) Manual of Practice No. 8 , vol.8