메뉴 건너뛰기




Volumn 38, Issue 4, 1997, Pages 397-402

The effect of preoperative infra-aortic balloon pump support in high risk patients requiring myocardial revascularization

Author keywords

Cardiac output, low; Coronary artery bypass; Coronary disease, therapy; Heart failure; Intra aortic pumping

Indexed keywords

ADULT; AGED; AORTA BALLOON; ARTICLE; CARDIOPULMONARY BYPASS; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY OBSTRUCTION; FEMALE; HEART FAILURE; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; INTENSIVE CARE UNIT; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; MORTALITY; MULTIVARIATE ANALYSIS; RISK FACTOR; UNSTABLE ANGINA PECTORIS; MIDDLE AGED; POSTOPERATIVE COMPLICATION; PREOPERATIVE CARE; REOPERATION;

EID: 0031203420     PISSN: 00219509     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (35)

References (17)
  • 1
    • 50549166322 scopus 로고
    • Diastolic balloon pumping (with carbon dioxide) in aorta: Mechanical assistance to failing circulation
    • Moulopolous SD, Topaz W, Kolff WJ. Diastolic balloon pumping (with carbon dioxide) in aorta: mechanical assistance to failing circulation. Am Heart J 1962;63:669-75.
    • (1962) Am Heart J , vol.63 , pp. 669-675
    • Moulopolous, S.D.1    Topaz, W.2    Kolff, W.J.3
  • 5
    • 0002663766 scopus 로고
    • Physiology of balloon pumping
    • New York: Mount Kisco, Futura Publishing Company
    • Bolooki H. Physiology of balloon pumping. Clinical application of intra-aortic balloon pump. New York: Mount Kisco, Futura Publishing Company, 1984.
    • (1984) Clinical Application of Intra-Aortic Balloon Pump
    • Bolooki, H.1
  • 6
    • 0014807141 scopus 로고
    • Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption and coronary blood flow in dogs
    • Powell WJ Jr, Daggett WM, Magro AE. Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption and coronary blood flow in dogs. Circ Res 1970;26:753-64.
    • (1970) Circ Res , vol.26 , pp. 753-764
    • Powell Jr., W.J.1    Daggett, W.M.2    Magro, A.E.3
  • 7
    • 0016156362 scopus 로고
    • Intra-aortic balloon counterpulsation - A review of physiological principles, clinical results, and device safety
    • Weber KT, Janicki JS. Intra-aortic balloon counterpulsation - a review of physiological principles, clinical results, and device safety. Ann Thorac Surg 1974;17:602-36.
    • (1974) Ann Thorac Surg , vol.17 , pp. 602-636
    • Weber, K.T.1    Janicki, J.S.2
  • 8
    • 0015708039 scopus 로고
    • Augmentation and redistribution of myocardial bloodflow during acute ischemia by intra-aortic balloon pumping
    • Gill C, Wechsler A, Newman G, Oldham H. Augmentation and redistribution of myocardial bloodflow during acute ischemia by intra-aortic balloon pumping. Ann Thorac Surg 1975;16:445-853.
    • (1975) Ann Thorac Surg , vol.16 , pp. 445-853
    • Gill, C.1    Wechsler, A.2    Newman, G.3    Oldham, H.4
  • 9
    • 0016230791 scopus 로고
    • Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping
    • Watson JT, Willerson JT, Fixler DE, Sugg NL. Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping. Circulation 1974;49/50 (Suppl II):249-54.
    • (1974) Circulation , vol.49-50 , Issue.SUPPL. II , pp. 249-254
    • Watson, J.T.1    Willerson, J.T.2    Fixler, D.E.3    Sugg, N.L.4
  • 10
    • 0027351820 scopus 로고
    • Risk-factors of septicemia and perioperative myocardial infarction in a cohort of patients supported with intra-aortic balloon pump (IABP) in the course of open heart surgery
    • Aksnes J, Abelnoor M, Berge V, Fjeld NBJ. Risk-factors of septicemia and perioperative myocardial infarction in a cohort of patients supported with intra-aortic balloon pump (IABP) in the course of open heart surgery. Eur J Cardiothorac Surg 1993;7:153-7.
    • (1993) Eur J Cardiothorac Surg , vol.7 , pp. 153-157
    • Aksnes, J.1    Abelnoor, M.2    Berge, V.3    Fjeld, N.B.J.4
  • 13
  • 15
    • 0023131016 scopus 로고
    • Intra-aortic balloon pump insertion: A randomized study comparing percutaneous and surgical techniques
    • Goldberg MJ, Kantrowitz A, Rubenfire M, Goodman G, Freed PS. Intra-aortic balloon pump insertion: a randomized study comparing percutaneous and surgical techniques. J Am Coll Cardiol 1987;9:515-23.
    • (1987) J Am Coll Cardiol , vol.9 , pp. 515-523
    • Goldberg, M.J.1    Kantrowitz, A.2    Rubenfire, M.3    Goodman, G.4    Freed, P.S.5
  • 16
    • 0019989862 scopus 로고
    • Clinical evaluation of the Percor percutaneous balloon: Cooperative study of 722 cases
    • Grayzel J. Clinical evaluation of the Percor percutaneous balloon: cooperative study of 722 cases. Circulation 1982;66(Suppl I):223-8.
    • (1982) Circulation , vol.66 , Issue.SUPPL. I , pp. 223-228
    • Grayzel, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.