메뉴 건너뛰기




Volumn 19, Issue 7, 1997, Pages 677-690

Computer simulation and optimization of ammonia-water absorption refrigeration systems

Author keywords

Absorption; Air conditioning; Ammonia water; Aqua ammonia; Computer simulation; Heat pump; Mathematical model; NH3 H2O; Optimization; Refrigeration

Indexed keywords

AMMONIA; COMPUTER SIMULATION; COMPUTER SOFTWARE; MATHEMATICAL MODELS; MIXTURES; OPTIMIZATION; THERMODYNAMIC PROPERTIES; WASTE HEAT UTILIZATION; WATER ABSORPTION;

EID: 0031199985     PISSN: 00908312     EISSN: None     Source Type: Trade Journal    
DOI: 10.1080/00908319708908882     Document Type: Article
Times cited : (22)

References (21)
  • 1
    • 0027693126 scopus 로고
    • Solar absorption heat transformer applications to absorption refrigeration machines
    • Ahachad, M., M. Charia, and A. Bernatchou. 1993. Solar absorption heat transformer applications to absorption refrigeration machines. International Journal of Energy Research 17:719-726.
    • (1993) International Journal of Energy Research , vol.17 , pp. 719-726
    • Ahachad, M.1    Charia, M.2    Bernatchou, A.3
  • 2
    • 0023089580 scopus 로고
    • Simulation of a solar driven aqua-ammonia absorption refrigeration system, Part 1: Mathematical description and system optimization
    • Arvares, S. G., and C. Trepp. 1987. Simulation of a solar driven aqua-ammonia absorption refrigeration system, Part 1: Mathematical description and system optimization. International Journal of Refrigeration 10:40-48.
    • (1987) International Journal of Refrigeration , vol.10 , pp. 40-48
    • Arvares, S.G.1    Trepp, C.2
  • 3
    • 85033314935 scopus 로고
    • Refrigerant properties
    • chap. 17, Atlanta, Ga.: ASHRAE
    • ASHRAE. 1993. Refrigerant properties. In 1993 ASHRAE handbook: Fundamentals, chap. 17, p. 17.81. Atlanta, Ga.: ASHRAE.
    • (1993) 1993 ASHRAE Handbook: Fundamentals
  • 4
    • 85033318108 scopus 로고
    • Absorption cooling, heating, and refrigeration equipment
    • chap. 40, Atlanta, Ga.: ASHRAE
    • ASHRAE. 1994. Absorption cooling, heating, and refrigeration equipment. In 1994 ASHRAE handbook: Refrigeration systems and applications, chap. 40, p. 40.1. Atlanta, Ga.: ASHRAE.
    • (1994) 1994 ASHRAE Handbook: Refrigeration Systems and Applications
  • 5
    • 0029323039 scopus 로고
    • Sensitivity analysis of an aqua-ammonia absorption refrigeration system (AARS)
    • Bayramoglu, M., and A. T. Bulgan. 1995. Sensitivity analysis of an aqua-ammonia absorption refrigeration system (AARS). Energy 20(6):567-571.
    • (1995) Energy , vol.20 , Issue.6 , pp. 567-571
    • Bayramoglu, M.1    Bulgan, A.T.2
  • 8
    • 0029247688 scopus 로고
    • Optimization of the thermodynamic model of aqua-ammonia absorption refrigeration systems
    • Bulgan. A. T. 1995. Optimization of the thermodynamic model of aqua-ammonia absorption refrigeration systems. Energy Conversion and Management 36(2):135-143.
    • (1995) Energy Conversion and Management , vol.36 , Issue.2 , pp. 135-143
    • Bulgan, A.T.1
  • 9
    • 33747829713 scopus 로고
    • The jet pump cycle - A Jow cost refrigerator option powered by waste heat
    • Eames, I. W., S. Aphornratana, and D.-W. Sun. 1995. The jet pump cycle - A Jow cost refrigerator option powered by waste heat. Heat Recovery Systems and CHP 15:711-721.
    • (1995) Heat Recovery Systems and CHP , vol.15 , pp. 711-721
    • Eames, I.W.1    Aphornratana, S.2    Sun, D.-W.3
  • 10
    • 0026254031 scopus 로고
    • Optimization of ammonia absorption refrigeration process: Effects of seasonal ambient temperature fluctuations
    • Ming, A.-J. 1991. Optimization of ammonia absorption refrigeration process: Effects of seasonal ambient temperature fluctuations. International Journal of Refrigeration 14:341-344.
    • (1991) International Journal of Refrigeration , vol.14 , pp. 341-344
    • Ming, A.-J.1
  • 11
    • 0028485494 scopus 로고
    • First law thermodynamic evaluation and simulation of ammonia-water absorption heat pump systems
    • Mumah, S. N., S. S. Adefila, and E. A. Arinze. 1994. First law thermodynamic evaluation and simulation of ammonia-water absorption heat pump systems. Energy Conversion and Management 35(8):737-750.
    • (1994) Energy Conversion and Management , vol.35 , Issue.8 , pp. 737-750
    • Mumah, S.N.1    Adefila, S.S.2    Arinze, E.A.3
  • 12
    • 85033277693 scopus 로고
    • Minimizing or maximizing a function
    • chap. E04, Oxford, U.K.: NAG
    • Numerical Algorithms Group. 1990. Minimizing or maximizing a function. NAG Fortran Library Manual Mark 14. chap. E04, vol. 3. Oxford, U.K.: NAG.
    • (1990) NAG Fortran Library Manual Mark 14 , vol.3
  • 13
    • 0029305871 scopus 로고
    • Simple functions for fast calculations of selected thermodynamic properties of the ammonia-water system
    • Patek, J., and J. Klomfar. 1995. Simple functions for fast calculations of selected thermodynamic properties of the ammonia-water system. International Journal of Refrigeration 18(4):228-234.
    • (1995) International Journal of Refrigeration , vol.18 , Issue.4 , pp. 228-234
    • Patek, J.1    Klomfar, J.2
  • 15
    • 0030266401 scopus 로고    scopus 로고
    • Variable geometry ejectors and their applications in ejector refrigeration system
    • Sun, D.-W. 1996. Variable geometry ejectors and their applications in ejector refrigeration system. Energy 21(10):919-929.
    • (1996) Energy , vol.21 , Issue.10 , pp. 919-929
    • Sun, D.-W.1
  • 16
    • 0031142322 scopus 로고    scopus 로고
    • Experimental investigation of the performance characteristics of a steam jet refrigeration system
    • Sun, D.-W. 1997a. Experimental investigation of the performance characteristics of a steam jet refrigeration system. Energy Sources 19:349-367.
    • (1997) Energy Sources , vol.19 , pp. 349-367
    • Sun, D.-W.1
  • 17
    • 0000234086 scopus 로고    scopus 로고
    • Solar powered combined ejector-vapor comparession cycle for air conditioning and refrigeration
    • Sun, D.-W. 1997b. Solar powered combined ejector-vapor comparession cycle for air conditioning and refrigeration. Energy Conversion and Management 38(5):479-491.
    • (1997) Energy Conversion and Management , vol.38 , Issue.5 , pp. 479-491
    • Sun, D.-W.1
  • 18
    • 0031103196 scopus 로고    scopus 로고
    • Thermodynamic design data and optimum design maps for absorption refrigeration systems
    • Sun, D.-W. 1997c. Thermodynamic design data and optimum design maps for absorption refrigeration systems. Applied Thermal Engineering 17(3):211-221.
    • (1997) Applied Thermal Engineering , vol.17 , Issue.3 , pp. 211-221
    • Sun, D.-W.1
  • 19
    • 0030258179 scopus 로고    scopus 로고
    • Performance characteristics of HCFC-123 ejector refrigeration cycles
    • Sun, D.-W., and I. W. Eames, 1996. Performance characteristics of HCFC-123 ejector refrigeration cycles. International Journal of Energy Research 20(10):871-885.
    • (1996) International Journal of Energy Research , vol.20 , Issue.10 , pp. 871-885
    • Sun, D.-W.1    Eames, I.W.2
  • 20
    • 0030103531 scopus 로고    scopus 로고
    • Evaluation of a novel combined ejector-absorption refrigeration cycle, 1: Computer simulation
    • Sun, D.-W., I. W. Eames, and S. Aphornratana. 1996. Evaluation of a novel combined ejector-absorption refrigeration cycle, 1: Computer simulation, international Journal of Refrigeration 19(3):172-180.
    • (1996) International Journal of Refrigeration , vol.19 , Issue.3 , pp. 172-180
    • Sun, D.-W.1    Eames, I.W.2    Aphornratana, S.3
  • 21
    • 0027556736 scopus 로고
    • Cooling capacity optimization of a waste heat absorption refrigeration cycle
    • Wu, C. 1993. Cooling capacity optimization of a waste heat absorption refrigeration cycle. Heat Recovery Systems and CHP 13(2):161-166.
    • (1993) Heat Recovery Systems and CHP , vol.13 , Issue.2 , pp. 161-166
    • Wu, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.