메뉴 건너뛰기




Volumn 209, Issue 1-2, 1997, Pages 49-56

Tribological behaviour of ion-implanted Ti6A14V sliding against polymers

Author keywords

Backscattering spectrometry; Ion implantation; Joint prostheses; Titanium

Indexed keywords

CONTACT-SLIDING; ION IMPLANTATION; POLYMERS; TITANIUM ALLOYS; WEAR;

EID: 0031195592     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0043-1648(96)07456-X     Document Type: Article
Times cited : (36)

References (35)
  • 1
    • 0023451146 scopus 로고
    • Titanium: The implant material of today
    • R. Van Noort, Titanium: the implant material of today, J. Mater. Sci., 22 (1987) 3801-3811.
    • (1987) J. Mater. Sci. , vol.22 , pp. 3801-3811
    • Van Noort, R.1
  • 2
    • 0343154332 scopus 로고
    • Titanium alloys for hip joint replacements
    • M. Semlitsch, Titanium alloys for hip joint replacements, Clin. Maier., 2 (1987) 1-13.
    • (1987) Clin. Maier. , vol.2 , pp. 1-13
    • Semlitsch, M.1
  • 4
    • 0025642529 scopus 로고
    • Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces
    • S. Nasser, P.A. Campbell, D. Kilgus, N. Kossovsky and H.C. Amstutz, Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces, Clin. Orthop., 261 (1990) 171-185.
    • (1990) Clin. Orthop. , vol.261 , pp. 171-185
    • Nasser, S.1    Campbell, P.A.2    Kilgus, D.3    Kossovsky, N.4    Amstutz, H.C.5
  • 6
    • 0024330679 scopus 로고
    • Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads
    • A.V. Lombardi, T.H. Mallory, B.K. Vaughn and P. Drouillard, Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads, J. Bone Joint Surg., 71-A (1989) 1337-1342.
    • (1989) J. Bone Joint Surg. , vol.71 A , pp. 1337-1342
    • Lombardi, A.V.1    Mallory, T.H.2    Vaughn, B.K.3    Drouillard, P.4
  • 7
    • 0028445986 scopus 로고
    • Three-body abrasive wear behaviour of orthopaedic implant bearing surfaces from titanium debris
    • R.A. Poggie, A.K. Mishra and J.A. Davidson, Three-body abrasive wear behaviour of orthopaedic implant bearing surfaces from titanium debris, J. Mater. Sci. Mater. Med., 5 (1994) 387-392.
    • (1994) J. Mater. Sci. Mater. Med. , vol.5 , pp. 387-392
    • Poggie, R.A.1    Mishra, A.K.2    Davidson, J.A.3
  • 8
    • 0021788860 scopus 로고
    • Wear improvement of surgical titanium alloys by ion implantation
    • P. Sioshansi, R.W. Oliver and F.D. Matthews, Wear improvement of surgical titanium alloys by ion implantation, J. Vac. Sci. Technol., A3 (1985) 2670-2674.
    • (1985) J. Vac. Sci. Technol. , vol.A3 , pp. 2670-2674
    • Sioshansi, P.1    Oliver, R.W.2    Matthews, F.D.3
  • 9
    • 0022907176 scopus 로고
    • The effect of nitrogen ion implantation on the abrasive wear resistance of the Ti-6A1-4V/ UHMWPE couple
    • J.M. Williams, M.F. Nichols and W. Zingg (Eds.), Materials Research Society, Pittsburgh
    • F.D. Matthews, K.W. Greer and D.L. Armstrong, The effect of nitrogen ion implantation on the abrasive wear resistance of the Ti-6A1-4V/ UHMWPE couple, in J.M. Williams, M.F. Nichols and W. Zingg (Eds.), Mat. Res. Soc. Symp. Proc. Vol. 55, Materials Research Society, Pittsburgh, 1986, pp. 243-252.
    • (1986) Mat. Res. Soc. Symp. Proc. , vol.55 , pp. 243-252
    • Matthews, F.D.1    Greer, K.W.2    Armstrong, D.L.3
  • 10
    • 0022877840 scopus 로고
    • Comparison of wear resistance of ion implanted surgical Ti-6A1-4V with other alloys
    • J.M. Williams, M.F. Nichols and W. Zingg (Eds.), Materials Research Society, Pittsburgh
    • Z. Jianqiang, Z. Xiaozhong, G. Zintang and L. Hengde, Comparison of wear resistance of ion implanted surgical Ti-6A1-4V with other alloys, in J.M. Williams, M.F. Nichols and W. Zingg (Eds.), Mat. Res. Soc. Symp. Proc. Vol. 55, Materials Research Society, Pittsburgh, 1986, pp. 229-235.
    • (1986) Mat. Res. Soc. Symp. Proc. , vol.55 , pp. 229-235
    • Jianqiang, Z.1    Xiaozhong, Z.2    Zintang, G.3    Hengde, L.4
  • 11
    • 0026895770 scopus 로고
    • Structural modifications induced by ion implantation in metals and polymers used for orthopaedic prostheses
    • J. Rieu, A. Pichat, L.M. Rabbe, A. Rambert, C. Chabrol and M. Robelet, Structural modifications induced by ion implantation in metals and polymers used for orthopaedic prostheses, Mater. Sci. Technol., 8 (1992) 589-593.
    • (1992) Mater. Sci. Technol. , vol.8 , pp. 589-593
    • Rieu, J.1    Pichat, A.2    Rabbe, L.M.3    Rambert, A.4    Chabrol, C.5    Robelet, M.6
  • 14
    • 0024541187 scopus 로고
    • Wear of ultrahigh molecular weight polyethylene sliding against surface-treated Ti6A14V, AISI 316 stainless steel and Vitallium
    • R. Martinella, S. Giovanardi and G. Palombarini, Wear of ultrahigh molecular weight polyethylene sliding against surface-treated Ti6A14V, AISI 316 stainless steel and Vitallium, Wear, 133 (1989) 267-279.
    • (1989) Wear , vol.133 , pp. 267-279
    • Martinella, R.1    Giovanardi, S.2    Palombarini, G.3
  • 16
    • 84976714952 scopus 로고
    • Wear of ion implanted pure titanium and Ti6A14V alloy against ultrahigh molecular weight polyethylene
    • J. Lausmaa, T. Röstlund and H. McKellop, Wear of ion implanted pure titanium and Ti6A14V alloy against ultrahigh molecular weight polyethylene, Surf. Eng., 7 (1991) 311-317.
    • (1991) Surf. Eng. , vol.7 , pp. 311-317
    • Lausmaa, J.1    Röstlund, T.2    McKellop, H.3
  • 17
    • 0041736660 scopus 로고
    • PMMA abrasion resistance of zirconia, TiN and ADLC surfaces
    • Berlin
    • A.K. Mishra and J.A. Davidson, PMMA abrasion resistance of zirconia, TiN and ADLC surfaces, Trans. 4th World Biomat. Cong., Berlin, 1992, p. 116.
    • (1992) Trans. 4th World Biomat. Cong. , pp. 116
    • Mishra, A.K.1    Davidson, J.A.2
  • 18
    • 0026035593 scopus 로고
    • New surface modification for Ti-6AI-7Nb alloy: Oxygen diffusion hardening (ODH)
    • R.M. Streicher, H. Weber, R. Schön and M. Semlitsch, New surface modification for Ti-6AI-7Nb alloy: oxygen diffusion hardening (ODH), Biomaterials, 12 (1991) 125-129.
    • (1991) Biomaterials , vol.12 , pp. 125-129
    • Streicher, R.M.1    Weber, H.2    Schön, R.3    Semlitsch, M.4
  • 20
    • 0022733016 scopus 로고
    • Surface modification of industrial components by ion implantation
    • P. Sioshansi, Surface modification of industrial components by ion implantation, Mater, Sci. Eng., 90 (1987) 373-383.
    • (1987) Mater, Sci. Eng. , vol.90 , pp. 373-383
    • Sioshansi, P.1
  • 21
    • 0001795468 scopus 로고
    • Backscattering spectrometry
    • J.R. Tesmer and M. Nastasi (Eds.), Materials Research Society, Pittsburgh
    • J.A. Leavitt, L.C. McIntyre and M.R. Weller, Backscattering spectrometry, in J.R. Tesmer and M. Nastasi (Eds.), Handbook of Modern Ion Beam Materials Analysis, Materials Research Society, Pittsburgh, 1995, pp. 37-81.
    • (1995) Handbook of Modern Ion Beam Materials Analysis , pp. 37-81
    • Leavitt, J.A.1    McIntyre, L.C.2    Weller, M.R.3
  • 22
    • 0041736655 scopus 로고
    • High energy backscattering analysis using RUMP
    • J.R. Tesmer, C.J. Maggiore, M. Nastasi, J.C. Barbour and J. W. Mayer (Eds.), Materials Research Society, Pittsburgh
    • L.R. Doolittle, High energy backscattering analysis using RUMP, in J.R. Tesmer, C.J. Maggiore, M. Nastasi, J.C. Barbour and J. W. Mayer (Eds.), High Energy and Heavy Ion Beams in Materials Analysis, Materials Research Society, Pittsburgh, 1990, pp. 175-182.
    • (1990) High Energy and Heavy Ion Beams in Materials Analysis , pp. 175-182
    • Doolittle, L.R.1
  • 24
    • 0001057191 scopus 로고
    • 16O elastic scattering resonance at 7.30-7.65 MeV and applications to oxygen depth profiling
    • 16O elastic scattering resonance at 7.30-7.65 MeV and applications to oxygen depth profiling, Nucl. Instr. Meth., B82 (1993) 393-398.
    • (1993) Nucl. Instr. Meth. , vol.B82 , pp. 393-398
    • Almeida, F.J.D.1    Davies, J.A.2    Jackman, T.E.3
  • 25
    • 0024666652 scopus 로고
    • Hardness testing - A new method for economical and physically meaningful microhardness testing
    • W. Weiler, Hardness testing - a new method for economical and physically meaningful microhardness testing, Brit. J. Non Destr. Test., 31 (1989) 252-258.
    • (1989) Brit. J. Non Destr. Test. , vol.31 , pp. 252-258
    • Weiler, W.1
  • 26
    • 0041736659 scopus 로고
    • Tribological properties of aluminium oxide ceramics
    • G.W, Hastings and D.F. Williams (Eds.), Wiley, Chichester
    • J. Hinterberger, M. Ungethüm and W. Plitz, Tribological properties of aluminium oxide ceramics, in G.W, Hastings and D.F. Williams (Eds.), Mechanical Properties of Biomaterials, Wiley, Chichester, 1980, pp. 73-82.
    • (1980) Mechanical Properties of Biomaterials , pp. 73-82
    • Hinterberger, J.1    Ungethüm, M.2    Plitz, W.3
  • 27
    • 0001893658 scopus 로고
    • The ring-on-disc method - Clinical significance of a wear-screening test of biomaterials for hip joint alloplasty
    • S.M. Perren and E. Schneider (Eds.), Martinus Nijoff, Dordrecht
    • A. Walter and W. Plitz, The ring-on-disc method - clinical significance of a wear-screening test of biomaterials for hip joint alloplasty, in S.M. Perren and E. Schneider (Eds.), Biomechanics: Current Interdisciplinary Research, Martinus Nijoff, Dordrecht, 1985, pp. 129-134.
    • (1985) Biomechanics: Current Interdisciplinary Research , pp. 129-134
    • Walter, A.1    Plitz, W.2
  • 28
    • 0023454081 scopus 로고
    • Composition, structure and wear resistance of Ti-6A1-4V implanted with carbon or boron to high doses
    • R.N. Bolster, I.L. Singer and R.G. Vardiman, Composition, structure and wear resistance of Ti-6A1-4V implanted with carbon or boron to high doses, Surf. Coat. Technol, 33 (1987) 469-477.
    • (1987) Surf. Coat. Technol , vol.33 , pp. 469-477
    • Bolster, R.N.1    Singer, I.L.2    Vardiman, R.G.3
  • 29
    • 0002592787 scopus 로고
    • Microstructural study of nitrogen-implanted Ti-6A1-4V alloy
    • X. Qiu, R.A. Dodd, J.R. Conrad, A. Chen and F.J. Worzala, Microstructural study of nitrogen-implanted Ti-6A1-4V alloy, Nucl. Instr. Meth., B59/60 (1991) 951-956.
    • (1991) Nucl. Instr. Meth. , vol.B59 , Issue.60 , pp. 951-956
    • Qiu, X.1    Dodd, R.A.2    Conrad, J.R.3    Chen, A.4    Worzala, F.J.5
  • 31
    • 0019899067 scopus 로고
    • The improvement of fatigue life inTi-6A1-4V by ion implantation
    • R.G. Vardiman and R.A. Kant, The improvement of fatigue life inTi-6A1-4V by ion implantation, J. Appl. Phys., 53 (1982) 690-694.
    • (1982) J. Appl. Phys. , vol.53 , pp. 690-694
    • Vardiman, R.G.1    Kant, R.A.2
  • 32
    • 0021374906 scopus 로고
    • The subsurface microstructure of nitrogen-implanted metals
    • R. Hutchings, The subsurface microstructure of nitrogen-implanted metals, Mater. Sci. Eng., 69 (1985) 129-138.
    • (1985) Mater. Sci. Eng. , vol.69 , pp. 129-138
    • Hutchings, R.1
  • 33
    • 4243350072 scopus 로고    scopus 로고
    • Characterization of a hafnium and nitrogen implanted titanium alloy
    • J.S. Williams, R.G. Elliman and M.C. Ridgway (Eds.), Elsevier, Amsterdam
    • D.M. Rück, H. Schmidt, N. Angert, O. Yoda, Y. Aoki and H. Naramoto, Characterization of a hafnium and nitrogen implanted titanium alloy, in J.S. Williams, R.G. Elliman and M.C. Ridgway (Eds.), Ion Beam Modification of Materials, Elsevier, Amsterdam, 1996, pp. 1016-1019.
    • (1996) Ion Beam Modification of Materials , pp. 1016-1019
    • Rück, D.M.1    Schmidt, H.2    Angert, N.3    Yoda, O.4    Aoki, Y.5    Naramoto, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.