메뉴 건너뛰기




Volumn 13, Issue 4, 1997, Pages 10-16

Polymer outdoor insulating materials part II-material considerations

Author keywords

Erosion resistance; Formulation; Hydrophobicity; Manufacturing process; Product design; Testing; Weathering resistance

Indexed keywords

ADDITIVES; CORROSION RESISTANCE; ELASTOMERS; EROSION; MATERIALS TESTING; PLASTICS FILLERS; PRODUCT DESIGN; SERVICE LIFE; SILICONES; STANDARDIZATION; WEATHERING;

EID: 0031191643     PISSN: 08837554     EISSN: None     Source Type: Journal    
DOI: 10.1109/57.603554     Document Type: Review
Times cited : (32)

References (18)
  • 2
    • 34250855188 scopus 로고
    • Polymeric Cable Terminations under Accelerated Aging in a Fog Chamber
    • April
    • R. Gorur, E. Cherney, and R. Hackam, "Polymeric Cable Terminations Under Accelerated Aging In A Fog Chamber," IEEE Trans. on Power Delivery, Vol. 4, No. 2, April 1989, pp. 842-849.
    • (1989) IEEE Trans. on Power Delivery , vol.4 , Issue.2 , pp. 842-849
    • Gorur, R.1    Cherney, E.2    Hackam, R.3
  • 4
    • 0026238254 scopus 로고
    • Contamination Performance of Silicone Rubber Cable Terminations
    • October
    • R. Gorur, L. Johnson, and H. Hervig, "Contamination Performance of Silicone Rubber Cable Terminations," IEEE Trans. on Power Delivery, Vol. 6, No. 4, October 1991, pp. 1361-1373.
    • (1991) IEEE Trans. on Power Delivery , vol.6 , Issue.4 , pp. 1361-1373
    • Gorur, R.1    Johnson, L.2    Hervig, H.3
  • 8
    • 85009039535 scopus 로고
    • IEEE Application Guide for Evaluating Nonceramic Materials for High-Voltage Outdoor Applications
    • IEEE Std 1133, "IEEE Application Guide for Evaluating Nonceramic Materials for High-Voltage Outdoor Applications," 1988.
    • (1988) IEEE Std 1133
  • 9
    • 0028197814 scopus 로고
    • Compounding of Ethylene-Propylene Polymers for Electrical Applications
    • January/February
    • M. Brown, "Compounding of Ethylene-Propylene Polymers for Electrical Applications," IEEE Electrical Insulation Magazine, Vol. 10, No. 1, January/February 1994, pp. 16-22.
    • (1994) IEEE Electrical Insulation Magazine , vol.10 , Issue.1 , pp. 16-22
    • Brown, M.1
  • 10
    • 84866196925 scopus 로고
    • Influence of Additives and Fillers on Polymeric Material Performance
    • panel on "Polymer Materials for Insulators, Terminations and Arresters," April 12, Chicago
    • R. Chang, "Influence of Additives and Fillers on Polymeric Material Performance," 1994 IEEE PES Transmission & Distribution Conference, panel on "Polymer Materials for Insulators, Terminations and Arresters," April 12, 1994, Chicago.
    • (1994) 1994 IEEE PES Transmission & Distribution Conference
    • Chang, R.1
  • 11
    • 38049049541 scopus 로고
    • Effects of Filler Level in RTV Silicone Rubber Coatings Used in HV Insulations
    • December
    • S. Kim, E. Cherney, and R. Hackam, "Effects of Filler Level in RTV Silicone Rubber Coatings Used in HV Insulations," IEEE Trans. on Electrical Insulation, Vol. 27, No. 6, December 1992, pp. 1065-1072.
    • (1992) IEEE Trans. on Electrical Insulation , vol.27 , Issue.6 , pp. 1065-1072
    • Kim, S.1    Cherney, E.2    Hackam, R.3
  • 12
    • 0029289708 scopus 로고
    • Role of the Size of Alumina Trihydrate Filler on the Life of RTV Silicone Rubber Coating
    • April
    • H. Deng, R. Hackam, and E. Cherney, "Role Of the Size of Alumina Trihydrate Filler on the Life of RTV Silicone Rubber Coating," IEEE Trans. on Power Delivery, Vol. 10, No. 2, April 1995, pp. 1012-1024.
    • (1995) IEEE Trans. on Power Delivery , vol.10 , Issue.2 , pp. 1012-1024
    • Deng, H.1    Hackam, R.2    Cherney, E.3
  • 13
    • 0026135778 scopus 로고
    • Electrical Performance of Polymer Housed Zinc Oxide Arresters under Contaminated Conditions
    • April
    • V. Chaudry, R. Gorur, M. Dyer, and R. Thallam, "Electrical Performance Of Polymer Housed Zinc Oxide Arresters Under Contaminated Conditions," IEEE Trans. on Power Delivery, Vol. 6, No. 2, April 1991, pp. 696-706.
    • (1991) IEEE Trans. on Power Delivery , vol.6 , Issue.2 , pp. 696-706
    • Chaudry, V.1    Gorur, R.2    Dyer, M.3    Thallam, R.4
  • 14
    • 5244364551 scopus 로고
    • IEEE Standard for Metal-Oxide Surge Arresters for Alternating Current Power Circuits
    • IEEE Std. C62.11, "IEEE Standard for Metal-Oxide Surge Arresters for Alternating Current Power Circuits," 1993.
    • (1993) IEEE Std. C62.11
  • 15
    • 5244301186 scopus 로고
    • IEEE Recommended Practice for Specifying Distribution Composite Insulators (Suspension Type)
    • IEEE Std. 1024, "IEEE Recommended Practice for Specifying Distribution Composite Insulators (Suspension Type)," 1988.
    • (1988) IEEE Std. 1024
  • 17
    • 5244227072 scopus 로고
    • Composite Insulators for AC Overhead Lines with a Nominal Voltage Greater than 1000V - Definitions, Test Methods and Acceptance Criteria
    • First Edition
    • IEC 1109, "Composite Insulators for AC Overhead Lines with a Nominal Voltage Greater than 1000V - Definitions, Test Methods and Acceptance Criteria," First Edition, 1992-03.
    • (1992) IEC 1109
  • 18
    • 5244268531 scopus 로고
    • A Life Assessment Study of Raychem's Modified Polyolefin Based Outdoor Insulating Non-Tracking and Erosion Resistant Material for Medium and High Voltage Power Products
    • August 5
    • Raychem Report PPR1046, "A Life Assessment Study of Raychem's Modified Polyolefin Based Outdoor Insulating Non-Tracking and Erosion Resistant Material for Medium and High Voltage Power Products," August 5, 1993.
    • (1993) Raychem Report PPR1046


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.