메뉴 건너뛰기




Volumn 10, Issue 6, 1997, Pages 685-688

Detection of thrombotic cuspal obstruction of an aortic bioprosthesis with transesophageal echocardiography

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE; ARTICLE; BIOPROSTHESIS; CASE REPORT; ECHOGRAPHY; HEART VALVE PROSTHESIS; HUMAN; MALE; MIDDLE AGED; THROMBOSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 0031178271     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0894-7317(97)70033-6     Document Type: Article
Times cited : (4)

References (11)
  • 2
    • 0023032403 scopus 로고
    • Early thrombosis of a porcine bioprosthesis in the aortic valve position
    • Lesnefsky E, Groves B, Woelfel G, Dauber I, Campbell D. Early thrombosis of a porcine bioprosthesis in the aortic valve position. Am J Cardiol 1986;58:1120-1.
    • (1986) Am J Cardiol , vol.58 , pp. 1120-1121
    • Lesnefsky, E.1    Groves, B.2    Woelfel, G.3    Dauber, I.4    Campbell, D.5
  • 3
    • 0026495875 scopus 로고
    • Mechanical cardiac valve thrombosis - Is fibrinolysis justified?
    • Roudat R, Labbe T, Lorient-Roudaut M, et al. Mechanical cardiac valve thrombosis - Is fibrinolysis justified? Circulation 1992;86(Suppl):II-8-15.
    • (1992) Circulation , vol.86 , Issue.SUPPL.
    • Roudat, R.1    Labbe, T.2    Lorient-Roudaut, M.3
  • 4
    • 0022558652 scopus 로고
    • A prospective evaluation of the Bjork-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses
    • Bloomfield P, Kitchin A, Wheatley D, Walbaum P, Lutz W, Miller C. A prospective evaluation of the Bjork-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses. Circulation 1986;73:1213-22.
    • (1986) Circulation , vol.73 , pp. 1213-1222
    • Bloomfield, P.1    Kitchin, A.2    Wheatley, D.3    Walbaum, P.4    Lutz, W.5    Miller, C.6
  • 5
    • 0017660966 scopus 로고
    • Pathologic findings after cardiac valve replacement with glutaraldohyde-fixed porcine valves
    • Fishbein M, Gissen S, Collins J Jr, Barsamian E, Cohn L. Pathologic findings after cardiac valve replacement with glutaraldohyde-fixed porcine valves. Am J Cardiol 1977;40:331-7.
    • (1977) Am J Cardiol , vol.40 , pp. 331-337
    • Fishbein, M.1    Gissen, S.2    Collins Jr., J.3    Barsamian, E.4    Cohn, L.5
  • 6
  • 8
    • 0025890275 scopus 로고
    • Acute thrombosis of an aortic bioprosthetic valve: Transthoracic and transesophageal echocardiographic findings
    • Adamick R, Gleckel L, Graver L. Acute thrombosis of an aortic bioprosthetic valve: transthoracic and transesophageal echocardiographic findings. Am Heart J 1991;122(part 1):241-2.
    • (1991) Am Heart J , vol.122 , Issue.1 PART , pp. 241-242
    • Adamick, R.1    Gleckel, L.2    Graver, L.3
  • 11
    • 0029127056 scopus 로고
    • Aortic bioprosthesis without early anticoagulation-risk of thromboembolism
    • Babin-Ebel J, Schmidt W, Eigel P, Elert O. Aortic bioprosthesis without early anticoagulation-risk of thromboembolism. Thorac Cardiovasc Surg 1995;43:212-4.
    • (1995) Thorac Cardiovasc Surg , vol.43 , pp. 212-214
    • Babin-Ebel, J.1    Schmidt, W.2    Eigel, P.3    Elert, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.