메뉴 건너뛰기




Volumn 42, Issue 2, 1997, Pages 89-94

Evaluation of binding of human serum albumin (HSA) to monoclonal and polyclonal antibody by means of piezoelectric immunosensing technique

Author keywords

Immunoreaction; Kinetic analysis; Quartz crystal microbalance; Sandwich method

Indexed keywords

ANTIBODIES; IMMUNOLOGY; PIEZOELECTRIC DEVICES;

EID: 0031177641     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)00188-3     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 0002874977 scopus 로고
    • Electrolytic determination of nanomolar concentrations of silver in solution with a piezoelectric quartz crystal
    • T. Nomura, M. Iijima, Electrolytic determination of nanomolar concentrations of silver in solution with a piezoelectric quartz crystal, Anal. Chim. Acta 131 (1981) 97-102.
    • (1981) Anal. Chim. Acta , vol.131 , pp. 97-102
    • Nomura, T.1    Iijima, M.2
  • 2
    • 0347816738 scopus 로고
    • Frequency of a quartz microbalance in contact with liquid
    • K.K. Kanazawa, J.G. Gordon II, Frequency of a quartz microbalance in contact with liquid, Anal. Chem. 57 (1985) 1770-1771.
    • (1985) Anal. Chem. , vol.57 , pp. 1770-1771
    • Kanazawa, K.K.1    Gordon J.G. II2
  • 3
    • 0001558127 scopus 로고
    • Experimental aspects of use of the quartz crystal microbalance in solution
    • S. Bruckenstein, M. Shay, Experimental aspects of use of the quartz crystal microbalance in solution, Electrochim. Acta 30 (1985) 1295-1300.
    • (1985) Electrochim. Acta , vol.30 , pp. 1295-1300
    • Bruckenstein, S.1    Shay, M.2
  • 4
    • 0022716449 scopus 로고
    • Liquid-phase piezoelectric and acoustic transmission studies of interfacial immunochemistry
    • M. Thompson, C.L. Arthur, G.K. Dhaliwal, Liquid-phase piezoelectric and acoustic transmission studies of interfacial immunochemistry, Anal. Chem. 58 (1986) 1206-1209.
    • (1986) Anal. Chem. , vol.58 , pp. 1206-1209
    • Thompson, M.1    Arthur, C.L.2    Dhaliwal, G.K.3
  • 5
    • 0002868991 scopus 로고
    • Cyclic voltammetry and quartz microbalance electrogravimetry of IgG and anti-IgG reactions on silver
    • E.S. Grabbe, R.P. Buck, O.R. Melroy, Cyclic voltammetry and quartz microbalance electrogravimetry of IgG and anti-IgG reactions on silver, J. Electroanal. Chem. 223 (1987) 67-78.
    • (1987) J. Electroanal. Chem. , vol.223 , pp. 67-78
    • Grabbe, E.S.1    Buck, R.P.2    Melroy, O.R.3
  • 6
    • 0020880123 scopus 로고
    • Microgravimetric immunoassay with piezoelectric crystals
    • J.E. Roederer, G.J. Bastiaans, Microgravimetric immunoassay with piezoelectric crystals, Anal. Chem. 55 (1983) 2333-2336.
    • (1983) Anal. Chem. , vol.55 , pp. 2333-2336
    • Roederer, J.E.1    Bastiaans, G.J.2
  • 7
    • 33845279726 scopus 로고
    • Amplified mass immunosorbent assay with a quartz crystal microbalance
    • R.C. Ebersole, M.D. Ward, Amplified mass immunosorbent assay with a quartz crystal microbalance, J. Am. Chem. Soc. 110 (1988) 8623-8628.
    • (1988) J. Am. Chem. Soc. , vol.110 , pp. 8623-8628
    • Ebersole, R.C.1    Ward, M.D.2
  • 8
    • 0024615734 scopus 로고
    • Determination of microbes and immunoglobulins using a piezoelectric biosensor
    • H. Muramatsu, E. Tamiya, I. Karube, Determination of microbes and immunoglobulins using a piezoelectric biosensor, J. Memb. Sci. 41 (1989) 281-290.
    • (1989) J. Memb. Sci. , vol.41 , pp. 281-290
    • Muramatsu, H.1    Tamiya, E.2    Karube, I.3
  • 11
    • 0025335588 scopus 로고
    • A new approach to the development of a reusable piezoelectric crystal biosensor
    • E. Prusak-Sochaczewski, J.H.T. Luong, A new approach to the development of a reusable piezoelectric crystal biosensor, Anal. Lett. 23 (1990) 401-409.
    • (1990) Anal. Lett. , vol.23 , pp. 401-409
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2
  • 12
    • 0027918114 scopus 로고
    • Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: Relationship between the frequency change and the mass of protein adsorbed
    • M. Muratsugu, F. Ohta, Y. Miya, T. Hosokawa, S. Kurosawa, N. Kamo, H. Ikeda, Quartz crystal microbalance for the detection of microgram quantities of human serum albumin: relationship between the frequency change and the mass of protein adsorbed, Anal. Chem. 65 (1993) 2933-2937.
    • (1993) Anal. Chem. , vol.65 , pp. 2933-2937
    • Muratsugu, M.1    Ohta, F.2    Miya, Y.3    Hosokawa, T.4    Kurosawa, S.5    Kamo, N.6    Ikeda, H.7
  • 13
    • 84951279351 scopus 로고
    • Verwendung von schwingquartzen zur wagung dunner schichten und zur mikrowagung
    • G. Sauerbrey, Verwendung von Schwingquartzen zur Wagung dunner Schichten und zur Mikrowagung, Z. Phys. 155 (1959) 206-222.
    • (1959) Z. Phys. , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 14
    • 0024405872 scopus 로고
    • Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays
    • K.A. Davis, T.R. Leary, Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays, Anal. Chem. 61 (1989) 1227-1230.
    • (1989) Anal. Chem. , vol.61 , pp. 1227-1230
    • Davis, K.A.1    Leary, T.R.2
  • 15
    • 0028237951 scopus 로고
    • Investigation of specific binding of antifluorescyl antibody and Fab to fluorescein lipids in Langmuir-Blodgett deposited films using quartz crystal microbalance methodology
    • H. Ebato, C.A. Gentry, J.N. Herron, W. Muller, Y. Okahata, H. Ringsdorf, P.A. Suci, Investigation of specific binding of antifluorescyl antibody and Fab to fluorescein lipids in Langmuir-Blodgett deposited films using quartz crystal microbalance methodology, Anal. Chem. 66 (1994) 1683-1689.
    • (1994) Anal. Chem. , vol.66 , pp. 1683-1689
    • Ebato, H.1    Gentry, C.A.2    Herron, J.N.3    Muller, W.4    Okahata, Y.5    Ringsdorf, H.6    Suci, P.A.7
  • 16
    • 0029273273 scopus 로고
    • Selective and repeatable detection of human serum albumin by using piezoelectric immunosensor
    • G. Sakai, T. Saiki, T. Uda, N. Miura, N. Yamazoe, Selective and repeatable detection of human serum albumin by using piezoelectric immunosensor, Sensors and Actuators B 24/25 (1995) 134-137.
    • (1995) Sensors and Actuators B , vol.24-25 , pp. 134-137
    • Sakai, G.1    Saiki, T.2    Uda, T.3    Miura, N.4    Yamazoe, N.5
  • 17
    • 0027595130 scopus 로고
    • Piezoelectric crystal immunosensor for sensitive detection methamphetamine (stimulant drug) in human urine
    • N. Miura, H. Higobashi, G. Sakai, A. Takeyasu, T. Uda, N. Yamazoe, Piezoelectric crystal immunosensor for sensitive detection methamphetamine (stimulant drug) in human urine, Sensors and Actuators B 13/14 (1993) 188-191.
    • (1993) Sensors and Actuators B , vol.13-14 , pp. 188-191
    • Miura, N.1    Higobashi, H.2    Sakai, G.3    Takeyasu, A.4    Uda, T.5    Yamazoe, N.6
  • 18
    • 0028592578 scopus 로고
    • A kinetic study of Concanavalin A binding to glycolipid monolayers by using a quartz-crystal microbalance
    • Y. Ebara, Y. Okahata, A kinetic study of Concanavalin A binding to glycolipid monolayers by using a quartz-crystal microbalance, J. Am. Chem. Soc. 116 (1994) 11209-11212.
    • (1994) J. Am. Chem. Soc. , vol.116 , pp. 11209-11212
    • Ebara, Y.1    Okahata, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.