메뉴 건너뛰기




Volumn 26, Issue 4, 1997, Pages 459-464

Uncemented Total Hip Replacements using the Mecron® Acetabular Cup - A Prospective Study

Author keywords

Loosening; Migration; Revision; Threaded acetabular components; Total hip arthroplasty

Indexed keywords

ALLOY; BIOMATERIAL; BONE CEMENT; TITANIUM;

EID: 0031175036     PISSN: 03044602     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (19)
  • 1
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in hip replacement
    • DeLee J G, Charnley J. Radiological demarcation of cemented sockets in hip replacement. Clin Orthop 1976; 121:20.
    • (1976) Clin Orthop , vol.121 , pp. 20
    • DeLee, J.G.1    Charnley, J.2
  • 2
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement
    • Mulroy R D, Harris W H. The effect of improved cementing techniques on component loosening in total hip replacement. J Bone Joint Surg 1990; 72B:757.
    • (1990) J Bone Joint Surg , vol.72 B , pp. 757
    • Mulroy, R.D.1    Harris, W.H.2
  • 3
    • 0021883869 scopus 로고
    • Report on the first decenium of clinical experience with a cementless ceramic total hip replacement
    • Mittelmeier H. Report on the first decenium of clinical experience with a cementless ceramic total hip replacement. Acta Orthop Belg 1985; 51:367.
    • (1985) Acta Orthop Belg , vol.51 , pp. 367
    • Mittelmeier, H.1
  • 4
    • 0020559913 scopus 로고
    • The madreporic cementless total hip arthroplasty. New experimental data and seven-year clinical follow-up study
    • Lord G, Bancel P. The madreporic cementless total hip arthroplasty. New experimental data and seven-year clinical follow-up study. Clin. Orthop 1983; 176:67.
    • (1983) Clin. Orthop , vol.176 , pp. 67
    • Lord, G.1    Bancel, P.2
  • 5
    • 0342359419 scopus 로고
    • Lord's cementless total hip replacement in young patients: 2-7years result
    • Herberts P, Malchau H, Romanus B, Wiklund L M. Lord's cementless total hip replacement in young patients: 2-7years result. Orthop Trans 1986; 10:442.
    • (1986) Orthop Trans , vol.10 , pp. 442
    • Herberts, P.1    Malchau, H.2    Romanus, B.3    Wiklund, L.M.4
  • 6
    • 0025354272 scopus 로고
    • Primary migration of fully-threaded acetabular prosthesis - A Roentgen stereophotogrammetric analysis
    • Kärrhölm J, Snorrason F. Primary migration of fully-threaded acetabular prosthesis - A Roentgen stereophotogrammetric analysis. J Bone JointSurg 1990; 72B:647.
    • (1990) J Bone JointSurg , vol.72 B , pp. 647
    • Kärrhölm, J.1    Snorrason, F.2
  • 8
    • 0025152777 scopus 로고
    • Threaded acetabular component for primary and revision total hip arthroplasty
    • Shaw J A, Bailey J H, Bruno A, Greer R B. Threaded acetabular component for primary and revision total hip arthroplasty. J Arthroplasty 1990; 5:201.
    • (1990) J Arthroplasty , vol.5 , pp. 201
    • Shaw, J.A.1    Bailey, J.H.2    Bruno, A.3    Greer, R.B.4
  • 9
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty
    • Harris W H. Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. J Bone Joint Surg 1969; 51A:737.
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737
    • Harris, W.H.1
  • 10
    • 0019962848 scopus 로고
    • A ten-year follow-up of one hundred consecutive Müller curve-stem total hip replacement arthroplasties
    • Sutherland C J, Wilde A H, Borden L S, Marks K E. A ten-year follow-up of one hundred consecutive Müller curve-stem total hip replacement arthroplasties. J Bone Joint Surg 1982; 64A:97.
    • (1982) J Bone Joint Surg , vol.64 A , pp. 97
    • Sutherland, C.J.1    Wilde, A.H.2    Borden, L.S.3    Marks, K.E.4
  • 11
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiological analysis of loosening
    • Gruen T A, McNeice G M, Amstutz HC."Modes of failure" of cemented stem-type femoral components: A radiological analysis of loosening. Clin Orthop 1979; 141:17.
    • (1979) Clin Orthop , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 13
  • 14
    • 0020579574 scopus 로고
    • Ring UPM total hip arthroplasty
    • Ring P A, Ring UPM total hip arthroplasty. Clin Orthop 1983; 176:115.
    • (1983) Clin Orthop , vol.176 , pp. 115
    • Ring, P.A.1
  • 15
    • 0024441094 scopus 로고
    • Evaluation of cementless acetabular components migrations
    • Massin P, Schmidt L, Engh C A. Evaluation of cementless acetabular components migrations. J Arthroplasty 1989; 4:245.
    • (1989) J Arthroplasty , vol.4 , pp. 245
    • Massin, P.1    Schmidt, L.2    Engh, C.A.3
  • 16
    • 0027178757 scopus 로고
    • Bone reaction to uncemented threaded polyethylene acetabular components
    • Krugluger J, Eyb R. Bone reaction to uncemented threaded polyethylene acetabular components. Int Orthop 1993; 17:259.
    • (1993) Int Orthop , vol.17 , pp. 259
    • Krugluger, J.1    Eyb, R.2
  • 19
    • 0024209828 scopus 로고
    • Design rationale in early clinical trials with a hemispherical threaded acetabular component
    • Cameroon H U, Bhimji S. Design rationale in early clinical trials with a hemispherical threaded acetabular component. J Arthroplasty 1988; 3:299.
    • (1988) J Arthroplasty , vol.3 , pp. 299
    • Cameroon, H.U.1    Bhimji, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.