메뉴 건너뛰기




Volumn 7, Issue 2 PART 1, 1997, Pages 590-593

Development of collar lamination strain gauges for coil stress measurements in superconducting accelerator magnets

Author keywords

[No Author keywords available]

Indexed keywords

ACCELERATOR MAGNETS; CALIBRATION; COOLING; ELECTRIC COILS; ELECTRIC EXCITATION; STRAIN GAGES; STRESS ANALYSIS; TRANSDUCERS;

EID: 0031169578     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/77.614573     Document Type: Article
Times cited : (1)

References (10)
  • 1
    • 0024627128 scopus 로고
    • Measurement of internal forces in superconducting accelerator magnets with strain gauge transducers
    • March
    • C. L. Goodzeit, M. D. Anerella, and G. L. Ganetis, "Measurement of internal forces in superconducting accelerator magnets with strain gauge transducers", IEEE Trans. Magn. ,vol. 25, no. 2, March 1989
    • (1989) IEEE Trans. Magn. , vol.25 , Issue.2
    • Goodzeit, C.L.1    Anerella, M.D.2    Ganetis, G.L.3
  • 2
    • 33747726570 scopus 로고
    • Investigation of factors affecting the calibration of strain gauge based transducers (Goodzeit gauges) for SSC magnets
    • J. Nonte, ed. New York: Plenum
    • M. Davidson, A. Gilbertson, and M. Dougherty, "Investigation of factors affecting the calibration of strain gauge based transducers ("Goodzeit gauges") for SSC magnets", in Supercollider 3, J. Nonte, ed. New York: Plenum, 1991
    • (1991) Supercollider 3
    • Davidson, M.1    Gilbertson, A.2    Dougherty, M.3
  • 4
    • 33747702492 scopus 로고    scopus 로고
    • Measurements Group, Inc. Raleigh, NC. 27611, USA
    • Measurements Group, Inc. Raleigh, NC. 27611, USA
  • 5
    • 33747639495 scopus 로고    scopus 로고
    • ibid., Model # SK-13-125MG-350
    • ibid., Model # SK-13-125MG-350
  • 6
    • 33747684294 scopus 로고    scopus 로고
    • Measurement Group, Inc.; M-Bond Adhesive # 610 , cured at 148 deg. C for 2 hours while pressure applied to the gauge surfaces, then cured at 189 deg. C for 2 hours without pressure applied.
    • Measurement Group, Inc.; M-Bond Adhesive # 610 , cured at 148 deg. C for 2 hours while pressure applied to the gauge surfaces, then cured at 189 deg. C for 2 hours without pressure applied.
  • 9
    • 84866212675 scopus 로고    scopus 로고
    • Mechanical design changes of the Tevatron's Low-β quadrupole for testing at 1.8K
    • R. Bossert, S. A. Gourlay, et al., "Mechanical design changes of the Tevatron's Low-β quadrupole for testing at 1.8K", paper LKB-1, this conference.
    • Paper LKB-1, this Conference
    • Bossert, R.1    Gourlay, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.