메뉴 건너뛰기




Volumn 119, Issue 4, 1997, Pages 22-31

Recognition of coherent swing in power systems and detection of step-out using power and current measured on tie lines

Author keywords

Coherency; Electric current; Electric power; Power system; Stability; Step out; Swing

Indexed keywords

ELECTRIC CURRENT MEASUREMENT; ELECTRIC GENERATORS; ELECTRIC LINES; ELECTRIC POWER MEASUREMENT; SYSTEM STABILITY;

EID: 0031164497     PISSN: 04247760     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1520-6416(199706)119:4<22::aid-eej3>3.0.co;2-l     Document Type: Article
Times cited : (1)

References (9)
  • 1
    • 5244280425 scopus 로고    scopus 로고
    • Development of effective analysis method for static stability of large-scale power systems
    • Suzuki, Sedei et al. Development of effective analysis method for static stability of large-scale power systems. Trans. I.E.E. Japan, Vol. 115-B, No. 1 (1995).
    • Trans. I.E.E. Japan , vol.115 B , Issue.1 , pp. 1995
    • Suzuki1    Sedei2
  • 2
    • 5244335052 scopus 로고
    • Estimation of dominant mode distribution using generator's rotor vibration, and its applications
    • Saito, Toyoda, and Kobayashi. Estimation of dominant mode distribution using generator's rotor vibration, and its applications. Trans. I.E.E. Japan, Vol. 110-B, No. 12 (1990).
    • (1990) Trans. I.E.E. Japan , vol.110 B , Issue.12
    • Saito1    Toyoda2    Kobayashi3
  • 3
    • 5244328476 scopus 로고
    • On-line high-speed stabilization in power systems using swing analysis
    • Sato, Tsukui, and Komata. On-line high-speed stabilization in power systems using swing analysis. Trans. I.E.E. Japan, Vol. 57 (1984).
    • (1984) Trans. I.E.E. Japan , vol.57
    • Sato1    Tsukui2    Komata3
  • 4
    • 5244246081 scopus 로고
    • Prevention of fault expansion in power systems
    • Oura, Suzuki et al. Prevention of fault expansion in power systems. Trans. I.E.E. Japan, Vol. 112-B, No. 7 (1992).
    • (1992) Trans. I.E.E. Japan , vol.112 B , Issue.7
    • Oura1    Suzuki2
  • 5
    • 5244305979 scopus 로고
    • Development of on-line stabilizing control for large-capacity power sources
    • Suzuki, Yanagibashi et al. Development of on-line stabilizing control for large-capacity power sources. Trans. I.E.E. Japan, Vol. 110-B (1990).
    • (1990) Trans. I.E.E. Japan , vol.110 B
    • Suzuki1    Yanagibashi2
  • 6
    • 5244312370 scopus 로고
    • Detection of long-period swing, and recognition of step-out in power systems
    • PE-93-27
    • Minagawa, Ichikawa, and Sato. Detection of long-period swing, and recognition of step-out in power systems. Conf. on Power Engineering 1993, PE-93-27.
    • (1993) Conf. on Power Engineering
    • Minagawa1    Ichikawa2    Sato3
  • 7
    • 5244276045 scopus 로고
    • Distance measures and coherency recognition for transient stability equivalents
    • T.Y. Stephen et al. Distance measures and coherency recognition for transient stability equivalents. IEEE, Vol. PAS-92, No. 5 (1973).
    • (1973) IEEE , vol.PAS-92 , Issue.5
    • Stephen, T.Y.1
  • 8
    • 0029407967 scopus 로고
    • Synchrony, aggregation, and multi-area eigenanalysis
    • G.N. Ramasway et al. Synchrony, aggregation, and multi-area eigenanalysis. IEEE Trans, on Power System, Vol. 10, No. 4, pp. 1896-1993 (1995).
    • (1995) IEEE Trans, on Power System , vol.10 , Issue.4 , pp. 1896-1993
    • Ramasway, G.N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.