Volumn 392, Issue 1-3, 1997, Pages 155-160
|
Performance of a resistive plate chamber operated in avalanche mode under 137Cs irradiation
|
Author keywords
CMS; Gas detectors; RPC
|
Indexed keywords
AVALANCHE DIODES;
CESIUM;
GAMMA RAYS;
GAS DETECTORS;
PERFORMANCE;
RADIATION EFFECTS;
RADIOISOTOPES;
RESISTIVE PLATE CHAMBERS;
IONIZATION CHAMBERS;
|
EID: 0031163721
PISSN: 01689002
EISSN: None
Source Type: Journal
DOI: 10.1016/S0168-9002(97)00240-4 Document Type: Article |
Times cited : (7)
|
References (8)
|