메뉴 건너뛰기




Volumn 21, Issue 3, 1997, Pages 107-114

Revisiting the component additive method for light-frame walls protected by gypsum board

Author keywords

[No Author keywords available]

Indexed keywords

BUILDING CODES; FIRE PROTECTION; FLAMMABILITY TESTING; GYPSUM; WALLS (STRUCTURAL PARTITIONS);

EID: 0031141961     PISSN: 03080501     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-1018(199705/06)21:3<107::AID-FAM587>3.0.CO;2-6     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 85033169966 scopus 로고    scopus 로고
    • Canadian Commission on Building and Fire Codes, National Building Code of Canada 1995, National Research Council of Canada, Ottawa
    • Canadian Commission on Building and Fire Codes, National Building Code of Canada 1995, National Research Council of Canada, Ottawa.
  • 7
    • 51249195278 scopus 로고
    • Ten rules of fire endurance rating
    • T. Z. Harmathy, Ten rules of fire endurance rating. Fire Technology 1, 93 (1965).
    • (1965) Fire Technology , vol.1 , pp. 93
    • Harmathy, T.Z.1
  • 8
    • 85033162454 scopus 로고    scopus 로고
    • Canadian Standards Association, Gypsum Board, National Standard of Canada CAN/CSA-A82.27-M91, Rexdale
    • Canadian Standards Association, Gypsum Board, National Standard of Canada CAN/CSA-A82.27-M91, Rexdale.
  • 10
    • 3643124902 scopus 로고
    • Fire performance of gypsum wallboard assemblies
    • September
    • S. Grayson (ed.), Fire performance of gypsum wallboard assemblies. Fire and Flammability Bulletin September (1993).
    • (1993) Fire and Flammability Bulletin
    • Grayson, S.1
  • 11
    • 85033189049 scopus 로고    scopus 로고
    • Canadian Standards Association, Gypsum Board Application, National Standard of Canada CAN/CSA-A82.31-M91, Rexdale
    • Canadian Standards Association, Gypsum Board Application, National Standard of Canada CAN/CSA-A82.31-M91, Rexdale.
  • 12
    • 3643101968 scopus 로고
    • Results of fire-resistance tests on full-scale, insulated and non-insulated, gypsum board protected wall assemblies
    • National Research Council Canada, Institute for Research in Construction
    • M. A. Sultan et al., Results of fire-resistance tests on full-scale, insulated and non-insulated, gypsum board protected wall assemblies. NRC Client Report A-4052.1, National Research Council Canada, Institute for Research in Construction (1994).
    • (1994) NRC Client Report A-4052.1
    • Sultan, M.A.1
  • 17
    • 85033168493 scopus 로고    scopus 로고
    • Forintek Canada Corp., personal communication
    • P. Lau, Forintek Canada Corp., personal communication.
    • Lau, P.1
  • 18
    • 85033163546 scopus 로고    scopus 로고
    • Forintek Canada Corp., personal communication
    • H. Takeda, Forintek Canada Corp., personal communication.
    • Takeda, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.