-
1
-
-
0001962062
-
Calibration and Manipulation of Data from Fuji Pressure-sensitive Film
-
ed. E.G. Little, Elsevier Science Publichers, Amsterdam
-
Liggins, A.B., Stranart, J.C.E., Finlay, J.B. and Rorabeck, C.H. "Calibration and Manipulation of Data from Fuji Pressure-sensitive Film," Experimental Mechanics: Technology Transfer Between High Tech Engineering and Biomechanics, ed. E.G. Little, Elsevier Science Publichers, Amsterdam, 61-70 (1992).
-
(1992)
Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics
, pp. 61-70
-
-
Liggins, A.B.1
Stranart, J.C.E.2
Finlay, J.B.3
Rorabeck, C.H.4
-
2
-
-
0005364936
-
Recording Contact Areas and Pressures in Joint Interfaces
-
ed. E.G. Little, Elsevier Science Publishers, Amsterdam
-
Liggins, A.B. and Finlay, J.B. "Recording Contact Areas and Pressures in Joint Interfaces," Experimental Mechanics: Technology Transfer Between High Tech Engineering and Biomechanics. ed. E.G. Little, Elsevier Science Publishers, Amsterdam, 71-88 (1992).
-
(1992)
Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics
, pp. 71-88
-
-
Liggins, A.B.1
Finlay, J.B.2
-
3
-
-
0026196188
-
Effects of Osteochondral Defect Size on Cartilage Contact Stress
-
Brown, T.D., Pope, D.F., Hale, J.E., Buckwater, J.A. and Brand, R.A. "Effects of Osteochondral Defect Size on Cartilage Contact Stress," J. Orthop. Res. 9 (4), 559-567 (1991).
-
(1991)
J. Orthop. Res.
, vol.9
, Issue.4
, pp. 559-567
-
-
Brown, T.D.1
Pope, D.F.2
Hale, J.E.3
Buckwater, J.A.4
Brand, R.A.5
-
4
-
-
84889520647
-
Measurements of Two Dimensional Pressure Distributions and Contact Areas of a Joint Using a Pressure Sensitive Foil
-
eds. R. Huiskes, D.H. Van Campen and J.R. De Wijn, Martinus Nijhoff, The Hague
-
Hechne, H.J., Haberland, H., Hultzsch, W. and Jantz, W. "Measurements of Two Dimensional Pressure Distributions and Contact Areas of a Joint Using a Pressure Sensitive Foil," Biomechanics: Principles and Appliccation, eds. R. Huiskes, D.H. Van Campen and J.R. De Wijn, Martinus Nijhoff, The Hague, 197-203 (1982).
-
(1982)
Biomechanics: Principles and Appliccation
, pp. 197-203
-
-
Hechne, H.J.1
Haberland, H.2
Hultzsch, W.3
Jantz, W.4
-
5
-
-
0026896794
-
Contact Characteristics of the Subtalar Joint: Load Distribution between the anterior and Posterior Facets
-
Wagner, U.A., Sangeorzan, B.J. Harrington, R.M. and Tencer, A.F., "Contact Characteristics of the Subtalar Joint: Load Distribution Between the anterior and Posterior Facets," J. Orthop. Res. 10 (4), 535-543 (1992).
-
(1992)
J. Orthop. Res.
, vol.10
, Issue.4
, pp. 535-543
-
-
Wagner, U.A.1
Sangeorzan, B.J.2
Harrington, R.M.3
Tencer, A.F.4
-
6
-
-
84889515842
-
The Spatial and Pressure Resolution of Fuji Pressure-sensitive Film
-
IN PRESS
-
Liggins, A.B., Hardie, W.R. and Finlay, J.B., "The Spatial and Pressure Resolution of Fuji Pressure-sensitive Film," EXPERIMENTAL MECHANICS, IN PRESS.
-
Experimental Mechanics
-
-
Liggins, A.B.1
Hardie, W.R.2
Finlay, J.B.3
-
7
-
-
0026911047
-
Contact Stress Gradient Detection Limits of Pressensor Film
-
Hale, J.E. and Brown, T.D., "Contact Stress Gradient Detection Limits of Pressensor Film," J. Biomechanical Eng., 114 (3), 352-357 (1992).
-
(1992)
J. Biomechanical Eng.
, vol.114
, Issue.3
, pp. 352-357
-
-
Hale, J.E.1
Brown, T.D.2
-
8
-
-
0004062334
-
-
John Wiley and Sons, Toronto. 5th ed.
-
Wonnacott, T.H. and Wonnacott, R.J., Introductory Statistics, John Wiley and Sons, Toronto. 5th ed., 266 (1990).
-
(1990)
Introductory Statistics
, pp. 266
-
-
Wonnacott, T.H.1
Wonnacott, R.J.2
-
9
-
-
0003750280
-
Image Enhancement
-
Addison-Wrsley Publishing Co., Reading, MA
-
Gonzalez, R.C. and Woods, R.E., "Image Enhancement," Digital Image Processing. Addison-Wrsley Publishing Co., Reading, MA, 187-188 (1992).
-
(1992)
Digital Image Processing
, pp. 187-188
-
-
Gonzalez, R.C.1
Woods, R.E.2
-
10
-
-
84889501114
-
Sealing Fuji Prescale Pressure-sensitive Film for Protection Against Fluid Damage: The Effect on its Response
-
IN PRESS
-
Liggins, A.B., Surry, K. and Finaly, J.B., "Sealing Fuji Prescale Pressure-sensitive Film for Protection Against Fluid Damage: The Effect on its Response," Strain, IN PRESS.
-
Strain
-
-
Liggins, A.B.1
Surry, K.2
Finaly, J.B.3
-
11
-
-
0028533947
-
Sterilization of Fuji Pressure-sensitive Film
-
Liggins, A.B., Hardie, W.R. and Finlay, J.B., "Sterilization of Fuji Pressure-sensitive Film," Med. Eng. Phys. 16 (6), 496-500 (1994).
-
(1994)
Med. Eng. Phys.
, vol.16
, Issue.6
, pp. 496-500
-
-
Liggins, A.B.1
Hardie, W.R.2
Finlay, J.B.3
-
12
-
-
0027530617
-
Effects of Partial Patellectomy and Reattachment of the Patellar Tendon an Patellofemoral Contact Anas and Pressures
-
Marder, R.A., Swanson, T.V., Sharkey, N.A. and Duwelius, P.J., "Effects of Partial Patellectomy and Reattachment of the Patellar Tendon an Patellofemoral Contact Anas and Pressures." J. Bone and Joint Surg, 75A (1), 35-45 (1993).
-
(1993)
J. Bone and Joint Surg
, vol.75 A
, Issue.1
, pp. 35-45
-
-
Marder, R.A.1
Swanson, T.V.2
Sharkey, N.A.3
Duwelius, P.J.4
|