Volumn 93, Issue 5, 1997, Pages 545-551

Description and initial clinical study of a digital chest X-ray selenium detector based system (Thoravision);Descrizione e valutazione clinica preliminare di un sistema radiografico digitale del torace con rivelatore al selenio (Thoravision)

Author keywords

Chest; Digital radiology

Indexed keywords

SELENIUM;

EID: 0031135103     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (19)
  • 1
    • 0001435228 scopus 로고
    • New chest imaging techniques: A comparison of five analogue and digital methods
    • Bush HP, Lehmann KJ, Drechsher P e Coll: New chest imaging techniques: a comparison of five analogue and digital methods. Eur J Radiol 2: 335-341, 1992.
    • (1992) Eur J Radiol , vol.2 , pp. 335-341
    • Bush, H.P.1    Lehmann, K.J.2    Drechsher, P.3
  • 2
    • 0028957128 scopus 로고
    • Technical evaluation of a digital chest radiography system that uses a selenium detector
    • Choats HG, Floyd CE, Ravin CE e Coll: Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology 195: 264-270, 1995
    • (1995) Radiology , vol.195 , pp. 264-270
    • Choats, H.G.1    Floyd, C.E.2    Ravin, C.E.3
  • 3
    • 0028914838 scopus 로고
    • Digital chest radiography: Comparison of unprocessed and processed images in the detection of solitary pulmonary nodules
    • Correa J, Souto M, Tahoces PG e Coll: Digital chest radiography: Comparison of unprocessed and processed images in the detection of solitary pulmonary nodules Radiology 195: 253-258, 1995.
    • (1995) Radiology , vol.195 , pp. 253-258
    • Correa, J.1    Souto, M.2    Tahoces, P.G.3
  • 4
    • 0026606935 scopus 로고
    • Threshold perception performance with computed and screen film radio graphy implications for chest radio-graphy
    • Dobbins JT, Rice JJ, Beam CA e Coll: Threshold perception performance with computed and screen film radio graphy implications for chest radio-graphy. Radiology 183: 179-187, 1992.
    • (1992) Radiology , vol.183 , pp. 179-187
    • Dobbins, J.T.1    Rice, J.J.2    Beam, C.A.3
  • 5
    • 0026663393 scopus 로고
    • Measurement of scatter fractions in clinical bedside radiography
    • Floyd CE, Baker JA, Lo JY e Coll. Measurement of scatter fractions in clinical bedside radiography. Radiology 183. 857-861, 1992.
    • (1992) Radiology , vol.183 , pp. 857-861
    • Floyd, C.E.1    Baker, J.A.2    Lo, J.Y.3
  • 6
    • 0028738064 scopus 로고
    • Evaluation of a selenium based digital chest radiography system
    • Floyd CE, Choats HG, Ravin CE. Evaluation of a selenium based digital chest radiography system, Proc SPIE 2163: 110-116, 1994
    • (1994) Proc SPIE , vol.2163 , pp. 110-116
    • Floyd, C.E.1    Choats, H.G.2    Ravin, C.E.3
  • 7
    • 0023611229 scopus 로고
    • Imaging performance of a digital storage phosphor system
    • Hillen W, Schiebel U, Zaengel T: Imaging performance of a digital storage phosphor system Med Phys 14 744-751, 1987.
    • (1987) Med Phys , vol.14 , pp. 744-751
    • Hillen, W.1    Schiebel, U.2    Zaengel, T.3
  • 8
    • 0345656965 scopus 로고
    • Imaging performance of a selenium-based detector for high-resolution radiography
    • Hillen W, Rupp S, Schiebel U e Coll: Imaging performance of a selenium-based detector for high-resolution radiography Proc SPIE 1090: 296-305, 1989.
    • (1989) Proc SPIE , vol.1090 , pp. 296-305
    • Hillen, W.1    Rupp, S.2    Schiebel, U.3
  • 9
    • 0029111952 scopus 로고
    • Effects of reduced exposure on computed radiography: Comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom
    • Kimme-Smith C, Aberle DR, Saire JW e Coll. Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom AJR 165: 269-273, 1994.
    • (1994) AJR , vol.165 , pp. 269-273
    • Kimme-Smith, C.1    Aberle, D.R.2    Saire, J.W.3
  • 10
    • 0028949964 scopus 로고
    • Detection of simulated chest lesions comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography
    • Leppert AGA, Prokop M, Shaefer-Prokop CMS e Coll: Detection of simulated chest lesions comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography. Radiology 195: 259-263, 1995.
    • (1995) Radiology , vol.195 , pp. 259-263
    • Leppert, A.G.A.1    Prokop, M.2    Shaefer-Prokop, C.M.S.3
  • 11
    • 0027343852 scopus 로고
    • Lesioni nodulari simulate su fantoccio antropomorfo toracico. Confronte tra immagini analogiche e digitali del torace
    • Miceli M, Stamati R, Burci P: Lesioni nodulari simulate su fantoccio antropomorfo toracico. Confronte tra immagini analogiche e digitali del torace Radiol Med 85: 54-58, 1993
    • (1993) Radiol Med , vol.85 , pp. 54-58
    • Miceli, M.1    Stamati, R.2    Burci, P.3
  • 12
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography a model calculation
    • Neitzel U: Grids or air gaps for scatter reduction in digital radiography a model calculation. Med Phys 19: 475-481, 1992.
    • (1992) Med Phys , vol.19 , pp. 475-481
    • Neitzel, U.1
  • 13
    • 0027742048 scopus 로고
    • Selenium: A new image detector for digital chest radiography
    • Neitzel U: Selenium: a new image detector for digital chest radiography. Medica Mundi 38: 89-93, 1993.
    • (1993) Medica Mundi , vol.38 , pp. 89-93
    • Neitzel, U.1
  • 14
    • 0028227069 scopus 로고
    • Image quality of a digital chest radiography system based on a selenium detector
    • Neitzel U, Maak I, Gunther-Kohfahl S: Image quality of a digital chest radiography system based on a selenium detector Med Phys 21: 509-516, 1994
    • (1994) Med Phys , vol.21 , pp. 509-516
    • Neitzel, U.1    Maak, I.2    Gunther-Kohfahl, S.3
  • 15
    • 0018859239 scopus 로고
    • Xeroradiography an indepth review
    • Paulus DD: Xeroradiography an indepth review. CRC Crit Rev Diagn Imaging 12: 309-394, 1990.
    • (1990) CRC Crit Rev Diagn Imaging , vol.12 , pp. 309-394
    • Paulus, D.D.1
  • 16
    • 0020559468 scopus 로고
    • A scanning system for chest radiography with regional exposure control practical implementation
    • Plewes DB, Vogelstein E: A scanning system for chest radiography with regional exposure control practical implementation. Med Phys 10: 655-663, 1983.
    • (1983) Med Phys , vol.10 , pp. 655-663
    • Plewes, D.B.1    Vogelstein, E.2
  • 17
    • 0023513057 scopus 로고
    • Effects of improved contrast on lung nodule detection: A clinical ROC study
    • Sorenson JA, Mitchell CR, Armstrong JD II e Coll: Effects of improved contrast on lung nodule detection: a clinical ROC study. Invest Radiol 22 772-780, 1987.
    • (1987) Invest Radiol , vol.22 , pp. 772-780
    • Sorenson, J.A.1    Mitchell, C.R.2    Armstrong II, J.D.3
  • 18
    • 0003994609 scopus 로고
    • Clinical evaluation of a new digital chest imaging system
    • Van Heesewijk HPM, De Valois JC Clinical evaluation of a new digital chest imaging system. Eur Radiol 5: 83-87, 1995.
    • (1995) Eur Radiol , vol.5 , pp. 83-87
    • Van Heesewijk, H.P.M.1    De Valois, J.C.2
  • 19
    • 0029143641 scopus 로고
    • Digital chest imaging with a selenium detector: Comparison with conventional radiography for visualization of specific anatomic regions of the chest
    • Van Heesewijk HPM, Neitzel U, Van der Graaf Y e Coll: Digital chest imaging with a selenium detector: comparison with conventional radiography for visualization of specific anatomic regions of the chest. AJR 165: 535-540, 1995.
    • (1995) AJR , vol.165 , pp. 535-540
    • Van Heesewijk, H.P.M.1    Neitzel, U.2    Van Der Graaf, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.