메뉴 건너뛰기




Volumn 93, Issue 5, 1997, Pages 613-617

Wiener spectrum of radiographic systems: Comparison of different evaluation methods

Author keywords

Noise; Wiener spectrum

Indexed keywords

ARTICLE; COMPARATIVE STUDY; METHODOLOGY; PHYSICS; RADIOGRAPHY;

EID: 0031132088     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (12)
  • 1
    • 2442539916 scopus 로고
    • Evaluation of image quality and sensitivity of radiographic screen-film systems
    • Borasi G, Piccagli V, Fenetti PP et al: Evaluation of image quality and sensitivity of radiographic screen-film systems Phys Med 5: 287-293, 1989.
    • (1989) Phys Med , vol.5 , pp. 287-293
    • Borasi, G.1    Piccagli, V.2    Fenetti, P.P.3
  • 5
    • 0017453285 scopus 로고
    • The characteristic of the computed tomographic reconstruction noise and their effect on detectability
    • Hanson KM, Boyd DP: The characteristic of the computed tomographic reconstruction noise and their effect on detectability. IEEE Trans Sci NS-25: 160-163, 1978
    • (1978) IEEE Trans Sci , vol.NS-25 , pp. 160-163
    • Hanson, K.M.1    Boyd, D.P.2
  • 6
    • 0021696386 scopus 로고
    • Crossover and MTF characteristics of the tabular-grain X-ray films SPIE
    • Kuff KE, Wagner PW: Crossover and MTF characteristics of the tabular-grain X-ray films SPIE. Med Imaging Instrum 486: 92-98, 1984.
    • (1984) Med Imaging Instrum , vol.486 , pp. 92-98
    • Kuff, K.E.1    Wagner, P.W.2
  • 7
    • 2442574563 scopus 로고
    • Threshold visual perception and its relationship to photon fluctuation and sine wawe response
    • Morgan RH. Threshold visual perception and its relationship to photon fluctuation and sine wawe response. AJR 93: 982-997, 1965.
    • (1965) AJR , vol.93 , pp. 982-997
    • Morgan, R.H.1
  • 8
    • 84957519673 scopus 로고
    • Sensitivity performance of human eye on an absolute scale
    • Rose A: Sensitivity performance of human eye on an absolute scale. J Optic Soc America 38. 196-208, 1948
    • (1948) J Optic Soc America , vol.38 , pp. 196-208
    • Rose, A.1
  • 9
    • 2442460705 scopus 로고
    • Recording of X-Ray quantum fluctuation in radiograph
    • Rossmann K: Recording of X-Ray quantum fluctuation in radiograph. J Optic Soc America 52 1162-1164, 1962.
    • (1962) J Optic Soc America , vol.52 , pp. 1162-1164
    • Rossmann, K.1
  • 10
    • 0020330446 scopus 로고
    • Radiographic screen-film noise power spectrum: Calibration and intercomparison
    • Sandrik JM, Wagner RE Hanson KM: Radiographic screen-film noise power spectrum: calibration and intercomparison. Appl Opt 21: 3597-3601, 1982.
    • (1982) Appl Opt , vol.21 , pp. 3597-3601
    • Sandrik, J.M.1    Wagner, R.E.2    Hanson, K.M.3
  • 11
    • 77049258424 scopus 로고
    • Optical and photoelectric analog of eye
    • Schade OH: Optical and photoelectric analog of eye. J Optic Soc America 46: 721-739, 1956.
    • (1956) J Optic Soc America , vol.46 , pp. 721-739
    • Schade, O.H.1
  • 12
    • 1542378640 scopus 로고
    • Two-dimensional noise power spectra of radiographic screen-film systems
    • Vranckx J, Breesch P, De Beider M. Two-dimensional noise power spectra of radiographic screen-film systems. Photogr Sci Engin 28: 134-136, 1984
    • (1984) Photogr Sci Engin , vol.28 , pp. 134-136
    • Vranckx, J.1    Breesch, P.2    De Beider, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.