메뉴 건너뛰기




Volumn 34, Issue 2, 1997, Pages 195-202

A modular six-directional force sensor for prosthetic assessment: A technical note

Author keywords

force sensor; lower limb amputation; prosthetic alignment; prosthetic fitting; prosthetics

Indexed keywords

ARTIFICIAL LIMBS; FORCE MEASUREMENT; GAIT ANALYSIS; STRAIN GAGES;

EID: 0031127909     PISSN: 07487711     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (35)

References (15)
  • 3
    • 0029411893 scopus 로고
    • Development of a non-linear finite element modelling of the below-knee prosthetic socket interface
    • Zhang M, Lord M, Turner-Smith AR, Roberts VC. Development of a non-linear finite element modelling of the below-knee prosthetic socket interface. Med Eng Phys 1995:17(8):559-66.
    • (1995) Med Eng Phys , vol.17 , Issue.8 , pp. 559-566
    • Zhang, M.1    Lord, M.2    Turner-Smith, A.R.3    Roberts, V.C.4
  • 4
    • 0030175670 scopus 로고    scopus 로고
    • Automated hexahedral mesh generation from biomedical image data: Applications in limb prosthetics
    • Zachariah SG, Sanders JE, Turkiyyah G. Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics. IEEE Trans Rehab Eng 1996:4(2):91-102.
    • (1996) IEEE Trans Rehab Eng , vol.4 , Issue.2 , pp. 91-102
    • Zachariah, S.G.1    Sanders, J.E.2    Turkiyyah, G.3
  • 5
    • 0023918273 scopus 로고
    • Biomechanics of below-knee amputee gait
    • Winter DA, Sienko SE. Biomechanics of below-knee amputee gait. J Biomech 1988:21(5):361-7.
    • (1988) J Biomech , vol.21 , Issue.5 , pp. 361-367
    • Winter, D.A.1    Sienko, S.E.2
  • 6
    • 0026071775 scopus 로고
    • Joint moment and muscle power output characteristics of below-knee amputees during running: The influence of energy storing prosthetic feet
    • Czerniecki JM, Gitter A, Munro C. Joint moment and muscle power output characteristics of below-knee amputees during running: the influence of energy storing prosthetic feet. J Biomech 1991:24(1):63-75.
    • (1991) J Biomech , vol.24 , Issue.1 , pp. 63-75
    • Czerniecki, J.M.1    Gitter, A.2    Munro, C.3
  • 8
    • 0021601379 scopus 로고
    • Analysis of gait following below-knee amputation: A comparison of the SACH and single-axis foot
    • Culham EG, Peat M, Newell E. Analysis of gait following below-knee amputation: a comparison of the SACH and single-axis foot. Physiother Can 1984:36(5):237-42.
    • (1984) Physiother Can , vol.36 , Issue.5 , pp. 237-242
    • Culham, E.G.1    Peat, M.2    Newell, E.3
  • 11
    • 0016558262 scopus 로고
    • A shorter pylon transducer for measurement of prosthetic forces and moments during amputee gait
    • Berme N, Lawes P, Solomonidis S, Paul JP. A shorter pylon transducer for measurement of prosthetic forces and moments during amputee gait. Eng Med 1976:4:6-8.
    • (1976) Eng Med , vol.4 , pp. 6-8
    • Berme, N.1    Lawes, P.2    Solomonidis, S.3    Paul, J.P.4
  • 12
    • 0023388917 scopus 로고
    • Least-squares matrix correlations between stump stresses and prosthesis loads for below-knee amputees
    • Winarski DJ, Pearson JR. Least-squares matrix correlations between stump stresses and prosthesis loads for below-knee amputees. J Biomech Eng 1987:109(3):238-46.
    • (1987) J Biomech Eng , vol.109 , Issue.3 , pp. 238-246
    • Winarski, D.J.1    Pearson, J.R.2
  • 15
    • 0028803381 scopus 로고
    • A small and lightweight three-channel signal-conditioning unit for strain-gage transducers: A technical note
    • Sanders JE, Smith LM, Spelman FA. A small and lightweight three-channel signal-conditioning unit for strain-gage transducers: a technical note. J Rehabil Res Dev 1995:32(3):210-3.
    • (1995) J Rehabil Res Dev , vol.32 , Issue.3 , pp. 210-213
    • Sanders, J.E.1    Smith, L.M.2    Spelman, F.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.